CARLO GAVAZZI PPB01CM23N PPB01CM23N CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABL.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PPB01CM23N CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABL..

PPB01CM23N

10000

CARLO GAVAZZI

1 Pcs.

Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABLE 3-phase AC voltage monitoring Others SIZE 36 mm POWER SUPPLY RANGE 208÷240 VAC MONITORING FUNCTION Under and over voltage, phase sequence, phase loss MOUTING Plug-in INPUT RANGE 208÷240 VAC DELAY 1, adjustable OTHERS VLN monitoring Three-phase, three-phase control relay with neutral, TRMS, Power supply 208 to 240 VAC 3-phase monitoring relay for phase loss, over or undervoltage, nominal range 380-480 V AC, delay on alarm 0.1-30 s, SPDT relay output, regenerated voltage detection, 36 mm plug-in housing

Automation > Phase monitoring relay
Monitoring Relays and Measurement Current Transformers

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Carlo Gavazzi PPB01CM23N monitoring relay serves as a dedicated guardian for multi-phase electrical lines, detecting voltage fluctuations and missing phases before they impact downstream machinery. Panel builders integrate this hardware into control panels to maintain strict operational safety standards across complex distribution networks.

Please note that specific pricing, availability, and lead times are confirmed per enquiry through an RFQ.

  • Type of electric connection (EF003961): Plug-in connection
  • With detachable clamps (EF003340): No
  • Phase sequence monitoring (EF003412): No
  • Phase failure detection (EF003413): Yes
  • Function under voltage detection (EF003414): Yes
  • Function over voltage detection (EF003415): Yes
  • Phase imbalance monitoring (EF003416): No
  • Max. permitted delay-on energization time (EF008189): 30 s
  • Width (EF000008): 36 mm
  • Height (EF000040): 80 mm
  • Depth (EF000049): 94 mm

More info

▲

Specifications

Mounting
Plug-in
Function
Phase loss; Overvoltage; Undervoltage
3-phase voltage range
208-240 Vac
Frequency range
50-60 Hz; 50-400 Hz
Output
1 relay
Time delay
No delay adjustment
Approvals, marks, declaration
for Europe; for North America; for Australia
Setting method through NFC
No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.