CARLO GAVAZZI DPB01CM23N DPB01CM23N CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABL.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DPB01CM23N CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABL..

DPB01CM23N

10000

CARLO GAVAZZI

1 Pcs.

Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABLE 3-phase AC voltage monitoring Others SIZE 22,5 mm POWER SUPPLY RANGE 208÷240 VAC MONITORING FUNCTION Under and over voltage, phase sequence, phase loss MOUTING DIN-rail INPUT RANGE 208÷240 VAC DELAY 1, adjustable OTHERS VLN monitoring Three-phase, three-phase control relay with neutral, TRMS, Power supply 208 to 240 VAC 3-phase monitoring relay for phase loss, over or undervoltage, nominal range 380-480 V AC, delay on alarm 0.1-30 s, SPDT relay output, regenerated voltage detection, 22.5 mm DIN-rail housing

Automation > Phase monitoring relay
Monitoring Relays and Measurement Current Transformers

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Carlo Gavazzi DPB01CM23N voltage monitoring relay provides critical safety functions by continuously tracking phase conditions and voltage limits in industrial installations. Panel builders install these devices to detect incorrect phase configurations and unsafe voltage levels before they compromise operational safety.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Type of electric connection (EF003961): Screw connection
  • With detachable clamps (EF003340): No
  • Phase sequence monitoring (EF003412): No
  • Phase failure detection (EF003413): Yes
  • Function under voltage detection (EF003414): Yes
  • Function over voltage detection (EF003415): Yes
  • Phase imbalance monitoring (EF003416): No
  • Max. permitted delay-on energization time (EF008189): 30 s
  • Width (EF000008): 22.5 mm
  • Height (EF000040): 83.5 mm
  • Depth (EF000049): 99.5 mm

More info

▲

Specifications

Mounting
Industrial DIN-rail
Function
Phase loss; Overvoltage; Undervoltage
3-phase voltage range
208-240 Vac
Frequency range
50-60 Hz
Output
1 relay
Time delay
Delay on alarm
Approvals, marks, declaration
for Europe; for North America; for China; for Australia
Setting method through NFC
No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.