CARLO GAVAZZI DUC01DB23500V DUC01DB23500V CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARI.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DUC01DB23500V CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARI..

DUC01DB23500V

23500

CARLO GAVAZZI

1 Pcs.

Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABLE 1-phase AC/DC voltage monitoring Others SIZE 45 mm POWER SUPPLY RANGE 115/230 VAC MONITORING FUNCTION Over and under voltage MOUTING DIN-rail INPUT RANGE 500 V DELAY 2, adjustable Single-phase control relay of max. voltage and min. AC / DC, TRMS, Measurement scale from 2 to 500 VAC / DC 1-phase AC/DC over and undervoltage monitoring relay, nominal range 2-500 V AC/DC, 2 SPDT relay outputs, 45 mm DIN-rail housing

Automation > Voltage monitoring relay
Monitoring Relays and Measurement Current Transformers

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Specifications

Supply Voltage
115/230 V AC
Mounting
Industrial DIN-rail
1-phase ac/dc voltage function
Over and undervoltage
Monitored voltage
Monitoring external voltage
1-phase voltage range
24-240 Vac/dc; 208-480 Vac; 2-500 Vac/dc
Output
2 relays
Time delay
Delay on alarm

ETIM for DUC01DB23500V Relays (EC001438)
Feature Name Feature Value
Type of electric connection (EF003961) Screw connection
With detachable clamps (EF003340) No
Single-phase under voltage possible (EF003390) Yes
Single-phase over voltage possible (EF003392) Yes
Three-phase over voltage possible (EF003393) No
Single-phase hysteresis possible (EF003394) Yes
Voltage measuring range 2 (EF006135) 0 V
Type of voltage measuring range (EF003399) AC/DC
Response value voltage (EF008193) 2 V
Min. adjustable delay-on energization time (EF008190) 0.1 s
Max. permitted delay-on energization time (EF008189) 30 s
Min. adjustable off-delay time (EF008192) 0.1 s
Max. permitted off-delay time (EF008191) 30 s
Number of contacts as change-over contact (EF008257) 2
Width (EF000008) 45 mm
Height (EF000040) 80 mm
Depth (EF000049) 99.5 mm