CARLO GAVAZZI DUB71CB48500V DUB71CB48500V CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, adjustable MONITORED VARI.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DUB71CB48500V CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, adjustable MONITORED VARI..

DUB71CB48500V

48500

CARLO GAVAZZI

1 Pcs.

Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, adjustable MONITORED VARIABLE 1-phase AC/DC voltage monitoring Others SIZE 36 mm POWER SUPPLY RANGE 24/48 VAC MONITORING FUNCTION Over or under voltage MOUTING DIN-rail INPUT RANGE 500 V DELAY 1, adjustable Single-phase control relay of max./min voltage AC/DC (TRMS), Measurement scale 2 to 500 V AC/DC 1-phase AC/DC over or undervoltage monitoring relay, nominal range 2-500 V AC/DC, SPDT relay output, 35.5 mm DIN-rail housing

Automation > Voltage monitoring relay
Monitoring Relays and Measurement Current Transformers

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Specifications

Supply Voltage
24/48 V AC
Mounting
Mini DIN-rail
1-phase ac/dc voltage function
Overvoltage; Undervoltage; Over or undervoltage
Monitored voltage
Monitoring external voltage
1-phase voltage range
24-240 Vac/dc; 208-480 Vac; 2-500 Vac/dc
Output
1 relay
Time delay
Delay on alarm

ETIM for DUB71CB48500V Relays (EC001438)
Feature Name Feature Value
Type of electric connection (EF003961) Screw connection
With detachable clamps (EF003340) No
Single-phase under voltage possible (EF003390) No
Single-phase over voltage possible (EF003392) No
Three-phase over voltage possible (EF003393) Yes
Single-phase hysteresis possible (EF003394) Yes
Contains function DC-voltage hysteresis (EF003398) Yes
Voltage measuring range 2 (EF006135) 0 V
Type of voltage measuring range (EF003399) AC/DC
Response value voltage (EF008193) 2 V
Min. adjustable delay-on energization time (EF008190) 0.1 s
Max. permitted delay-on energization time (EF008189) 30 s
Min. adjustable off-delay time (EF008192) 0.1 s
Max. permitted off-delay time (EF008191) 30 s
Number of contacts as change-over contact (EF008257) 1
Width (EF000008) 35.5 mm
Height (EF000040) 81 mm
Depth (EF000049) 67.2 mm

Product Datasheet