Selected parameters FUNCTION Light curtains SAFETY CATEGORY 4 SAFETY OUTPUT 3 NO Others SIZE 22 mm CONNECTIONS Screw-fixed POWER SUPPLY 24 VDC MOUNTING DIN-rail AUX OUTPUT 1 NC OTHERS Monitored manual start Security module - Safety barrier. Fixed screw terminals Safety Module Light Curtains , according to 2006/42/EC Machinery Directive, Power Supply 24VDC , 3 NO safety outputs, 1 NC auxiliary output , Monitored manual reset, DIN rail mount 22.5mm.

Automation > Device for monitoring of safety-related circuits
Light Curtains and Safety Light Curtains

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Specifications

Safety inputs
1-channel or 1- and 2-channel
Safety instantaneous relay outputs
3
Auxiliary relay outputs
1
EN ISO 13849-1 PL
Level e
Operating voltage
20.4 V ... 26.4 V
Housing width
22.5 mm

ETIM for NLG13D724SC Relays (EC001449)
Feature Name Feature Value
Model (EF000010) Basic device
Suitable for monitoring of position switches (EF007270) No
Suitable for monitoring of emergency-stop circuits (EF007268) No
Suitable for monitoring of valves (EF007272) No
Suitable for monitoring of optoelectronic protection equipment (EF007269) Yes
Suitable for monitoring of tactile sensors (EF007271) No
Suitable for monitoring of magnetic switches (EF007266) No
Suitable for monitoring of proximity switches (EF007267) No
Type of electric connection (EF003961) Screw connection
Suitable for rail mounting (EF003972) Yes
With detachable clamps (EF003340) No
Evaluation inputs (EF008245) 1-channel or 1- and 2-channel
With start input (EF003342) Yes
With muting function (EF004057) No
With feedback circuit (EF003343) No
Release-delay (EF001129) 0 s
Number of outputs, safety related, undelayed, with contact (EF003344) 3
Number of outputs, safety related, delayed, with contact (EF003345) 0
Number of outputs, safety related, undelayed, semiconductors (EF003346) 0
Number of outputs, safety related, delayed, semiconductors (EF003347) 0
Number of outputs, signalling function, undelayed, with contact (EF003348) 1
Number of outputs, signalling function, delayed, with contact (EF003349) 0
Number of outputs, signalling function, undelayed, semiconductors (EF003350) 0
Number of outputs, signalling function, delayed, semiconductors (EF003351) 0
Type of safety according to IEC 61496-1 (EF004105) None
Stop category according to IEC 60204 (EF007498) 0
Performance level according to EN ISO 13849-1 (EF007399) Level e
With approval for BG BIA (EF004145) No
With approval according to UL (EF001783) Yes
Width (EF000008) 22.5 mm
Height (EF000040) 99 mm