CARLO GAVAZZI DPD02DM44B DPD02DM44B CARLO GAVAZZI Output signal: 2 relays , Setpoints: Multiple setpoints, Monitored variable: 3-phas.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DPD02DM44B CARLO GAVAZZI Output signal: 2 relays , Setpoints: Multiple setpoints, Monitored variable: 3-phas..

DPD02DM44B

10000

CARLO GAVAZZI

1 Pcs.

Output signal: 2 relays , Setpoints: Multiple setpoints, Monitored variable: 3-phase AC voltage and frequency monitoring, Size: 22,5 mm, Power supply range: 208÷480 VAC , Monitoring function: Under and over voltage/frequency, phase sequence, phase loss, Mouting: DIN-rail, Input range: 208÷480 VAC , Delay: 2 for each alarm, Others: NFC Communication Relay control three-phase or three-phase + neutral rated Voltage 240VAC, 2 Outputs SPDT 3-phase monitoring relay for phase loss, sequence, neutral loss, asymmetry, over and undervoltage, over and underfrequency, nominal range 208-480 V AC, delay on alarm 0.1-60 s, 2 SPDT relay outputs, NFC communication, 22.5 mm DIN-rail housing

Automation > Phase monitoring relay
Monitoring Relays and Measurement Current Transformers

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Specifications

Mounting
Industrial DIN-rail
Function
Phase sequence; Phase loss; Neutral loss; Overvoltage; Undervoltage; Voltage asymmetry; Frequency
3-phase voltage range
208-240 Vac; 208-480 Vac; 380-480 Vac; 440-480 Vac
Frequency range
50-60 Hz; 50-400 Hz
Output
2 relays
Time delay
Delay on alarm
Approvals, marks, declaration
for Europe; for North America; for China; for Australia
Setting method through NFC
Yes

ETIM for DPD02DM44B Relays (EC001441)
Feature Name Feature Value
Type of electric connection (EF003961) Screw connection
With detachable clamps (EF003340) No
Phase sequence monitoring (EF003412) Yes
Phase failure detection (EF003413) Yes
Function under voltage detection (EF003414) Yes
Function over voltage detection (EF003415) Yes
Phase imbalance monitoring (EF003416) Yes
Max. permitted delay-on energization time (EF008189) 60 s
Max. permitted off-delay time (EF008191) 600 s
Width (EF000008) 22.5 mm
Height (EF000040) 84 mm
Depth (EF000049) 99.5 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.