View larger
603349 4TQA603349R0000 AEG RCCB/FP AI/2 40/0.03
603349
603349
AEG
1 unit
Automation > Tertiary
Tertiary
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Protecting circuits against earth leakage faults, a residual current circuit breaker continuously monitors current balance to disconnect faulty circuits before hazards occur. Installations rely on components like this Aeg 603349 unit to safeguard human life and equipment integrity.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Extended Product Type: FP AI 2 40/030
- Product ID: 4TQA603349R0000
- Catalog Description: FP AI 2 40/030 Residual Current Circuit Breaker 2P AI type 30 mA
- Standards: IEC/EN 60898-1
- Type of Residual Current: AI type
- Rated Operational Voltage: 240 V AC
- Rated Insulation Voltage (U i ): acc. to IEC/EN 60664-1 440 V
- Rated Impulse Withstand Voltage (U imp ): 6 kV
- Input Voltage Type: AC
- Rated Current (I n ): 40 A
- Rated Residual Current: 30 mA
- Rated Service Short-Circuit Breaking Capacity (I cs ): 10 kA
- Maximum Surge Current: 3000 kA
- Rated Frequency (f): 50/60 Hz
- Number of Protected Poles: 2
- Number of Poles: 2
More info
▲- Extended Product Type:
- FP AI 2 40/030
- Product ID:
- 4TQA603349R0000
- EAN:
- 5411815226717
- Catalog Description:
- FP AI 2 40/030 Residual Current Circuit Breaker 2P AI type 30 mA
- Long Description:
- The FP series RCCB is providing the protection for the people against the leakage currents. Including different types and sensitivities for a wide set of applications.
Technical
- Standards:
- IEC/EN 60898-1
- Type of Residual Current:
- AI type
- Rated Operational Voltage:
- 240 V AC
- Rated Insulation Voltage (Ui):
- acc. to IEC/EN 60664-1 440 V
- Rated Impulse Withstand Voltage (Uimp):
- 6 kV
- Input Voltage Type:
- AC
- Rated Current (In):
- 40 A
- Rated Residual Current:
- 30 mA
- Rated Service Short-Circuit Breaking Capacity (Ics):
- 10 kA
- Maximum Surge Current:
- 3000 kA
- Rated Frequency (f):
- 50/60 Hz
- Number of Protected Poles:
- 2
- Number of Poles:
- 2
- Operating Characteristic:
- Instantaneous (APR High Immunity)
- Position of Neutral Terminals:
- Right
- Mounting Type:
- DIN-Rail
- Accessories Available:
- Yes
- Rated Cross-Section:
- 1 - Solid-Core 1 ... 1 mm²
4 - Multi-Wired 1 ... 1 mm²
Environmental
- Ambient Air Temperature:
- Operation 40 ... 40 °C
- Degree of Protection:
- IP20
- Pollution Degree:
- 3
- RoHS Status:
- Following EU Directive 2011/65/EU
- RoHS Information:
- 2CSC423016D2701
- SCIP:
- 9e2f20b3-dc7e-4191-b2a8-11c001e37b5b Italy (IT)
- Conflict Minerals Reporting Template (CMRT):
- 9AKK108468A3363
Technical UL/CSA
- Short-Circuit Current Rating (SCCR):
- 0.03 A
Dimensions
- Width in Number of Modular Spacings:
- 2
- Product Net Width:
- 36mm
- Product Net Height:
- 70mm
- Product Net Depth / Length:
- 91mm
- Product Net Weight:
- 0.197kg
- Built-In Depth (t2):
- 44 mm
Ordering
- Package Level 1 Units:
- box 1 piece
- Package Level 1 Gross Weight:
- 0.213 kg
Certificates and Declarations
- Declaration of Conformity - CE:
- No declaration needed
Installation
- Instructions and Manuals:
- No document needed
Popular Downloads
- Data Sheet, Technical Information:
- No document needed
Classifications
- ETIM 8:
- EC000003 - Residual current circuit breaker (RCCB)
- ETIM 9:
- EC000003 - Residual current circuit breaker (RCCB)
- WEEE Category:
- 5. Small Equipment (No External Dimension More Than 50 cm)
- WEEE B2C / B2B:
- Business To Business
- CN8:
- 8536 20 10
- UNSPSC:
- 39121614
- eClass:
- V7.0 : 27142207
- Object Classification Code:
- Q