View larger
603345 4TQA603345R0000 AEG RCCB/FP A/2 63/0.3
603345
603345
AEG
1 unit
Automation > Tertiary
Tertiary
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed to safeguard electrical infrastructure from insulation breakdown and earth leakage, residual current devices are standard components in commercial and industrial electrical panels. The Aeg 603345 model delivers dependable fault isolation for specific operational requirements.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Extended Product Type: FP A 2 63/300
- Product ID: 4TQA603345R0000
- Catalog Description: FP A 2 63/300 Residual Current Circuit Breaker 2P A type 300 mA
- Standards: IEC/EN 60898-1
- Type of Residual Current: A type
- Rated Operational Voltage: 240 V AC
- Rated Insulation Voltage (U i ): acc. to IEC/EN 60664-1 440 V
- Rated Impulse Withstand Voltage (U imp ): 6 kV
- Input Voltage Type: AC
- Rated Current (I n ): 63 A
- Rated Residual Current: 300 mA
- Rated Service Short-Circuit Breaking Capacity (I cs ): 10 kA
- Maximum Surge Current: 250 kA
- Rated Frequency (f): 50/60 Hz
- Number of Protected Poles: 2
- Number of Poles: 2
More info
▲- Extended Product Type:
- FP A 2 63/300
- Product ID:
- 4TQA603345R0000
- EAN:
- 5411815226328
- Catalog Description:
- FP A 2 63/300 Residual Current Circuit Breaker 2P A type 300 mA
- Long Description:
- The FP series RCCB is providing the protection for the people against the leakage currents. Including different types and sensitivities for a wide set of applications.
Technical
- Standards:
- IEC/EN 60898-1
- Type of Residual Current:
- A type
- Rated Operational Voltage:
- 240 V AC
- Rated Insulation Voltage (Ui):
- acc. to IEC/EN 60664-1 440 V
- Rated Impulse Withstand Voltage (Uimp):
- 6 kV
- Input Voltage Type:
- AC
- Rated Current (In):
- 63 A
- Rated Residual Current:
- 300 mA
- Rated Service Short-Circuit Breaking Capacity (Ics):
- 10 kA
- Maximum Surge Current:
- 250 kA
- Rated Frequency (f):
- 50/60 Hz
- Number of Protected Poles:
- 2
- Number of Poles:
- 2
- Operating Characteristic:
- Instantaneous
- Position of Neutral Terminals:
- Right
- Mounting Type:
- DIN-Rail
- Accessories Available:
- Yes
- Rated Cross-Section:
- 1 - Solid-Core 1 ... 1 mm²
4 - Multi-Wired 1 ... 1 mm²
Environmental
- Ambient Air Temperature:
- Operation 40 ... 40 °C
- Degree of Protection:
- IP20
- Pollution Degree:
- 3
- RoHS Status:
- Following EU Directive 2011/65/EU
- RoHS Information:
- 2CSC423016D2701
- Conflict Minerals Reporting Template (CMRT):
- 9AKK108468A3363
Technical UL/CSA
- Short-Circuit Current Rating (SCCR):
- 0.0003 A
Dimensions
- Width in Number of Modular Spacings:
- 2
- Product Net Width:
- 36mm
- Product Net Height:
- 70mm
- Product Net Depth / Length:
- 91mm
- Product Net Weight:
- 0.197kg
- Built-In Depth (t2):
- 44 mm
Ordering
- Package Level 1 Units:
- box 1 piece
- Package Level 1 Gross Weight:
- 0.213 kg
Certificates and Declarations
- Declaration of Conformity - CE:
- No declaration needed
Installation
- Instructions and Manuals:
- No document needed
Popular Downloads
- Data Sheet, Technical Information:
- No document needed
Classifications
- ETIM 8:
- EC000003 - Residual current circuit breaker (RCCB)
- ETIM 9:
- EC000003 - Residual current circuit breaker (RCCB)
- WEEE Category:
- 5. Small Equipment (No External Dimension More Than 50 cm)
- WEEE B2C / B2B:
- Business To Business
- CN8:
- 8536 20 10
- UNSPSC:
- 39121614
- eClass:
- V7.0 : 27142207
- Object Classification Code:
- Q