View larger
1SDA068290R1
068290
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2351 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1857 |
| 9AKK108468A1892 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | e892b32f-ea36-48b8-bc7c-71fc89dff3dc Italy (IT) |
| Simplified SCIP | 98b60f48-949e-4922-a732-a257acfc2556 Belgium (BE) |
| 047224d6-341f-4ceb-b5d1-799d15f31097 Spain (ES) | |
| 3932a036-1147-4a6e-bae5-4e545001b570 Hungary (HU) | |
| e15d2996-933f-4771-be60-3c77a7ca6cbb France (FR) | |
| 7161de68-b323-459f-9a19-4f775b0e21c7 France (FR) | |
| d946bcb3-3ce6-42aa-8f52-eef4f7191f2d Germany (DE) | |
| 70edc77c-62b9-4606-9845-db447a8ee360 Denmark (DK) | |
| 0c5ed89d-4722-482e-aa6e-de6db783b349 Sweden (SE) | |
| 47178771-ecae-43e1-b997-5020b1c03b85 Germany (DE) | |
| 319ece15-11dc-4253-a904-5eb8d5f88e8a Czech Republic (CZ) | |
| 8f3a55d1-f4e8-4bd0-a4da-9367a82cabb2 Germany (DE) | |
| 33eb83bb-56ce-418f-90de-18e35ad1c905 Croatia (HR) | |
| 03c55fc0-cc52-437e-b7c0-22724682b68b Portugal (PT) | |
| 25628c46-3c57-4524-8b05-ee77ce43bf92 Germany (DE) | |
| de76c7d6-a7b5-434d-9dc8-147643ce7e3b Greece (GR) | |
| d2b1b542-8801-4cf9-a667-84503f871d41 Estonia (EE) | |
| f7f5bc43-98f9-427c-aadd-16c267c6b4e1 Hungary (HU) | |
| 3ca50727-00cb-49c9-abb9-605b0942be39 Finland (FI) | |
| 4145e41a-f613-4415-b928-d916b791cfe5 Poland (PL) | |
| 38dcfbe9-a015-475b-8766-83939d1e8ad8 Belgium (BE) | |
| 98c9dea6-43cb-448a-9b7f-8c9f97d3ef04 Germany (DE) | |
| d3a90fa8-691c-48b7-a24b-2c15a86f34f4 Poland (PL) | |
| 2d72a187-1ad1-4a3f-8f38-0c6413255184 Poland (PL) | |
| 9ae26fe3-874a-42d0-b43d-99851406dc93 Bulgaria (BG) | |
| 073c16fb-8363-43e4-afe8-fc5655c798a7 Norway (NO) | |
| 4852d2a1-53b3-4ae1-badf-718851fc569b Sweden (SE) | |
| 1b0a02a3-38db-46bb-aa65-4a715a0be758 Netherlands (NL) | |
| Ordering | |
| E-Number (Finland) | 3641071 |
| EAN | 8015644022013 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.65 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 171 mm |
| Package Level 1 Height | 215 mm |
| Package Level 1 Depth / Length | 151 mm |
| Package Level 1 Gross Weight | 2.1 kg |
| Package Level 1 EAN | 8015644022013 |
| Additional Information | |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Breaking Part |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 12 kA | |
| (250 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 3 Poles in Series 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 12 kA | |
| (250 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 3 Poles in Series 50 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Version | F |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| Instructions and Manuals | 1SDH000722R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |