View larger
1SDA068290R1 ABB XT4S160 PART OF INTERRUPTION 3P F F
1SDA068290R1
068290
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SDA068290R1 XT4S160 PART OF INTERRUPTION 3P F F is a molded case circuit breaker component that assists in interrupting fault currents and safeguarding industrial circuits from electrical overloads. It is integrated into larger panel configurations to maintain system reliability. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 56.30 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2351
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108469A1857
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: e892b32f-ea36-48b8-bc7c-71fc89dff3dc Italy (IT)
- Simplified SCIP: 98b60f48-949e-4922-a732-a257acfc2556 Belgium (BE)
- E-Number (Finland): 3641071
- EAN: 8015644022013
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2351 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1857 |
| 9AKK108468A1892 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | e892b32f-ea36-48b8-bc7c-71fc89dff3dc Italy (IT) |
| Simplified SCIP | 98b60f48-949e-4922-a732-a257acfc2556 Belgium (BE) |
| 047224d6-341f-4ceb-b5d1-799d15f31097 Spain (ES) | |
| 3932a036-1147-4a6e-bae5-4e545001b570 Hungary (HU) | |
| e15d2996-933f-4771-be60-3c77a7ca6cbb France (FR) | |
| 7161de68-b323-459f-9a19-4f775b0e21c7 France (FR) | |
| d946bcb3-3ce6-42aa-8f52-eef4f7191f2d Germany (DE) | |
| 70edc77c-62b9-4606-9845-db447a8ee360 Denmark (DK) | |
| 0c5ed89d-4722-482e-aa6e-de6db783b349 Sweden (SE) | |
| 47178771-ecae-43e1-b997-5020b1c03b85 Germany (DE) | |
| 319ece15-11dc-4253-a904-5eb8d5f88e8a Czech Republic (CZ) | |
| 8f3a55d1-f4e8-4bd0-a4da-9367a82cabb2 Germany (DE) | |
| 33eb83bb-56ce-418f-90de-18e35ad1c905 Croatia (HR) | |
| 03c55fc0-cc52-437e-b7c0-22724682b68b Portugal (PT) | |
| 25628c46-3c57-4524-8b05-ee77ce43bf92 Germany (DE) | |
| de76c7d6-a7b5-434d-9dc8-147643ce7e3b Greece (GR) | |
| d2b1b542-8801-4cf9-a667-84503f871d41 Estonia (EE) | |
| f7f5bc43-98f9-427c-aadd-16c267c6b4e1 Hungary (HU) | |
| 3ca50727-00cb-49c9-abb9-605b0942be39 Finland (FI) | |
| 4145e41a-f613-4415-b928-d916b791cfe5 Poland (PL) | |
| 38dcfbe9-a015-475b-8766-83939d1e8ad8 Belgium (BE) | |
| 98c9dea6-43cb-448a-9b7f-8c9f97d3ef04 Germany (DE) | |
| d3a90fa8-691c-48b7-a24b-2c15a86f34f4 Poland (PL) | |
| 2d72a187-1ad1-4a3f-8f38-0c6413255184 Poland (PL) | |
| 9ae26fe3-874a-42d0-b43d-99851406dc93 Bulgaria (BG) | |
| 073c16fb-8363-43e4-afe8-fc5655c798a7 Norway (NO) | |
| 4852d2a1-53b3-4ae1-badf-718851fc569b Sweden (SE) | |
| 1b0a02a3-38db-46bb-aa65-4a715a0be758 Netherlands (NL) | |
| Ordering | |
| E-Number (Finland) | 3641071 |
| EAN | 8015644022013 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.65 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 171 mm |
| Package Level 1 Height | 215 mm |
| Package Level 1 Depth / Length | 151 mm |
| Package Level 1 Gross Weight | 2.1 kg |
| Package Level 1 EAN | 8015644022013 |
| Additional Information | |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Breaking Part |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 12 kA | |
| (250 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 3 Poles in Series 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 12 kA | |
| (250 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 3 Poles in Series 50 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Version | F |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| Instructions and Manuals | 1SDH000722R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |