View larger
1SDA068505R1 ABB XT4S 250 Ekip LSI In 250A 4p F F
1SDA068505R1
068505
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB XT4S 250 Ekip LSI In 250A 4p F F is a molded case circuit breaker utilized to protect electrical distributions against overcurrents and short circuits. This hardware is routinely installed in manufacturing plants and commercial switchboards to ensure reliable circuit isolation and precise fault interruption.
Exact pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 56.30 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2352
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108469A1858
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 03c5300e-5a37-484a-9da3-6269c54a3611 Italy (IT)
- Simplified SCIP: 8a679b49-33e9-4b8c-ae41-4dc4947a6608 France (FR)
- Order Code US and Canada: XT4SE4250FFF000XXX
- EAN: 8015644024116
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2352 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1858 |
| 9AKK108468A1898 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 03c5300e-5a37-484a-9da3-6269c54a3611 Italy (IT) |
| Simplified SCIP | 8a679b49-33e9-4b8c-ae41-4dc4947a6608 France (FR) |
| 1c76d99a-f6f7-454a-be66-c46770109f87 Germany (DE) | |
| ee96ba51-0d4c-49ff-8aeb-6bc95791be9f Germany (DE) | |
| 3776a7ef-2799-4903-93d1-fb6573a0bf84 Sweden (SE) | |
| d544752f-e7f4-4bc0-aa45-6a93b5293f73 Denmark (DK) | |
| e71ab250-3c3a-45e9-962d-df2cfc18b62a Germany (DE) | |
| 77d3271b-4c46-4187-b0e0-8f9d26596b4b Croatia (HR) | |
| fc5c94db-f545-4f04-a452-3426ad6b3cfe Czech Republic (CZ) | |
| 00ce6966-10e0-434b-adbb-946a67a468a6 Spain (ES) | |
| d02b95b9-488e-4f67-96a2-cf4528215802 Hungary (HU) | |
| 57b4abd4-2d21-4e31-9b34-a4974338c9e9 Belgium (BE) | |
| 710a5bb0-6fde-4167-a5d8-865293a28e82 Belgium (BE) | |
| fe3ccd83-b2cd-45da-aea3-22568b7e9eaf Estonia (EE) | |
| 685a67d3-444e-43a4-afc1-f90b6fbebfb0 Poland (PL) | |
| 39d05bc5-a54c-4eeb-a990-e19449d6962e Hungary (HU) | |
| 514f670e-e2cb-4ba5-afcf-31940b7ef97e Finland (FI) | |
| e815d3a5-177f-48d7-8ca5-0658f1804a6f Greece (GR) | |
| 80e2e1f4-1162-44f1-a387-259fa7830d15 Germany (DE) | |
| 18622ce1-dc20-4102-8ac0-69dc7133ba31 Germany (DE) | |
| 2fd106a2-8628-481e-a619-ea3590dcd5a4 Portugal (PT) | |
| 556d48e0-4fae-4c7b-bbd1-2aa027e291bf France (FR) | |
| b6b5bbea-e1f9-415f-8c7a-d2e8e498869d Sweden (SE) | |
| 63731631-a0ac-4f79-a700-0a884ac61d7a Norway (NO) | |
| 80ac8a18-fb72-4d65-a7d4-9dda8c4c05ad Poland (PL) | |
| 433c272f-0d77-4c8d-b327-9e917f325f01 Bulgaria (BG) | |
| 08e0d7dc-3437-4fe8-90dd-2c55b4096501 Poland (PL) | |
| dbf16b3c-1666-4ed6-86e7-6e1cbb3f6534 Netherlands (NL) | |
| Ordering | |
| Order Code US and Canada | XT4SE4250FFF000XXX |
| EAN | 8015644024116 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 3.05 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 151 mm |
| Package Level 1 Height | 214 mm |
| Package Level 1 Depth / Length | 171 mm |
| Package Level 1 Gross Weight | 3.11 kg |
| Package Level 1 EAN | 8015644024116 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 85..200 mm² |
| Current Type | AC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 4 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 16.40 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 250 A |
| Rated Frequency (f) | 50/60 Hz |
| Rated Voltage (Ur) | 690 V AC |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V AC |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 12 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 12 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Recommended Screw Driver | Main Circuit M8 |
| Release | Ekip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0677 |
| Technical UL/CSA | |
| Interrupting Rating acc. to UL489 | (240 V AC) 100 A |
| (480 V AC) 35 A | |
| (600 V AC) 22 A | |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000722R0100 |
| Mechanical Drawings | 1SDH000722R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000722R0001 |
| 1SDH000721R0506 | |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |