A moulded case circuit breaker with electronic release, specifically the Abb 1SDA068475R1 ABB XT4S 250 Ekip LS/I In 250A 3p F F, provides dependable protection for electrical feeders against overloads and short circuits. These versatile breakers are standard in commercial and industrial control panels to ensure system safety and selectivity.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 56.30 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2352
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108469A1858
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: a0b4793c-54b1-4ffb-8743-71005e613fa4 Italy (IT)
- Simplified SCIP: 79f83248-c671-4520-b1e0-e4d1c878bbe0 Germany (DE)
- Order Code US and Canada: XT4SE3250EFF000XXX
- E-Number (Finland): 3641048
- E-Number (Sweden): 3182045
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2352 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1858 |
| 9AKK108468A1898 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | a0b4793c-54b1-4ffb-8743-71005e613fa4 Italy (IT) |
| Simplified SCIP | 79f83248-c671-4520-b1e0-e4d1c878bbe0 Germany (DE) |
| a07e90e9-40ca-4259-be5d-18eb5b419ef0 Germany (DE) | |
| 1b023db3-3601-469a-8ca2-7ed83a765ed1 Croatia (HR) | |
| 1cd49d4c-7ad1-4636-b617-ff06482b0b19 Czech Republic (CZ) | |
| 42bc31df-f5ef-477d-8461-0981ef96605d Netherlands (NL) | |
| 0f8e1c65-9bfd-45ad-b7e9-796835cf5d0c Estonia (EE) | |
| 4cbb8db6-d6e1-4369-8740-1bb8ed92651b Greece (GR) | |
| cd4a8ef0-c7a2-4505-95bd-df95e41cf576 Portugal (PT) | |
| c2acc7f0-049c-419e-baae-2ade41c763e4 Bulgaria (BG) | |
| 709f389d-1062-4a3d-907d-29755f502419 Sweden (SE) | |
| ca5a1d7d-d477-4b0f-8bb4-d3aa9158b46a Poland (PL) | |
| 28a764f6-113e-44e3-82cb-4b30e2e75ac3 Poland (PL) | |
| 3022e371-6ed0-49bc-888c-ddedb659d63a Netherlands (NL) | |
| 4570c748-512d-4c25-8947-7f6bafa8e801 France (FR) | |
| 3397e787-8df2-4466-9ca4-706ab0c8d996 Sweden (SE) | |
| be5030b1-2a27-4336-9408-1f8b5d38b858 Germany (DE) | |
| ab60e0dd-810e-4d85-a004-1c71e135ddda Germany (DE) | |
| b8c4c683-f22e-4b69-b211-1e60c36789da France (FR) | |
| bfb82c68-1e70-45b9-ac0e-730b2eebbef7 Netherlands (NL) | |
| bc9000b4-80af-4d2d-b4a3-0319354b56a9 Spain (ES) | |
| c4f2001b-a8bf-4771-a499-0af66b3d4db6 Netherlands (NL) | |
| 9bc0d3a7-511a-490a-b6d6-6c62bf4be76d Poland (PL) | |
| 439d6ad0-a509-4f3c-a3d1-75ec682c66e9 Norway (NO) | |
| 8baf0533-48db-4141-98a7-adc8f9a2d2fd Finland (FI) | |
| 14c33def-6b73-4a32-9884-9304171755d1 Netherlands (NL) | |
| e99b5c83-eea8-4ad7-a49e-7e46cbed9f54 Germany (DE) | |
| 7bcf544c-945e-4e25-b425-36b3ed2ab407 Denmark (DK) | |
| Ordering | |
| Order Code US and Canada | XT4SE3250EFF000XXX |
| E-Number (Finland) | 3641048 |
| E-Number (Sweden) | 3182045 |
| EAN | 8015644023812 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 2.314 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 151 mm |
| Package Level 1 Height | 214 mm |
| Package Level 1 Depth / Length | 171 mm |
| Package Level 1 Gross Weight | 2.436 kg |
| Package Level 1 EAN | 8015644023812 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 85..200 mm² |
| Current Type | AC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 16.4 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 250 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 12 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 12 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Recommended Screw Driver | Main Circuit M8 |
| Release | Ekip Dip LS/I |
| Release Type | EL |
| RoHS Date | NA |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1003 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000722R0100 |
| Mechanical Drawings | 1SDH000722R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000722R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |