View larger
1SDA068289R1 ABB XT4N160 PART OF INTERRUPTION 3P F F
1SDA068289R1
068289
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This 1SDA068289R1 ABB XT4N160 PART OF INTERRUPTION 3P F F component serves as a specialized element within industrial circuit interruption assemblies. Such parts are integrated into broader electrical protection systems to maintain continuity and safety across automated manufacturing lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 56.30 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2351
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108469A1857
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 097b6b86-fa5f-4ba7-bb7b-34f344d56449 Italy (IT)
- Simplified SCIP: 7eb2f659-a982-45a5-ac8f-1f5c778800d7 Germany (DE)
- E-Number (Finland): 3641066
- EAN: 8015644021108
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2351 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1857 |
| 9AKK108468A1892 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 097b6b86-fa5f-4ba7-bb7b-34f344d56449 Italy (IT) |
| Simplified SCIP | 7eb2f659-a982-45a5-ac8f-1f5c778800d7 Germany (DE) |
| dae4a40b-932f-411b-b23e-96315ee37902 Germany (DE) | |
| f5b3cf4d-2a13-48dc-86e9-1daf819a2e7b Denmark (DK) | |
| 9d9bf786-ae52-497c-acdb-e28abb935c55 Germany (DE) | |
| a4d18f8d-d57b-4643-bfd2-239be83dcaa8 Croatia (HR) | |
| 84d1a5a0-4f67-4ee1-9b83-9634650b6d41 Czech Republic (CZ) | |
| 20acc5a8-d429-4ed3-9150-0b7e457dc0b9 Poland (PL) | |
| caa174b4-ef0d-43bf-929f-2e00738ba2fa Netherlands (NL) | |
| 977a8410-57e8-4056-94cd-7526658c0dbe France (FR) | |
| e896b857-6b47-485e-8b1a-e527fdf667ad Sweden (SE) | |
| 736985a8-65d1-49a3-97cd-103b5deea829 Germany (DE) | |
| 1a840cd9-81a9-4b6f-9835-9c7aa6d58852 Germany (DE) | |
| 0b68d9ff-9f3a-41f2-9b94-7afddfe403b1 France (FR) | |
| eb3d161e-cc87-4ada-b065-d01ee00e8c51 Netherlands (NL) | |
| 9166dbc3-affb-4267-8a86-29ddca20353d Spain (ES) | |
| 88f4d449-c1f8-4ea5-8b94-a6222f45961d Netherlands (NL) | |
| 8a096653-f6f2-4837-8d29-72c5b00c37dc Poland (PL) | |
| 4cb05895-5c86-42bc-89cc-73b6d71e3ca5 Norway (NO) | |
| 08240c8a-1ea1-47fa-aea4-f9c91689143a Finland (FI) | |
| dd4b2fc4-f319-4f30-8840-e5e30d3cd651 Netherlands (NL) | |
| 59f11515-fd97-400f-8690-5941648e5774 Netherlands (NL) | |
| ea74a0a5-d8a8-4a32-a065-90d513d44e09 Estonia (EE) | |
| 8abfda39-8fbf-4611-8dea-b82f0803b558 Greece (GR) | |
| 460a6277-f5fb-49f4-87a7-60d4158b006f Portugal (PT) | |
| 34db6172-2e40-40a6-9654-c01e2984e171 Bulgaria (BG) | |
| 3fd2b569-f081-46c5-923b-48b616b484d5 Sweden (SE) | |
| 28dc8772-e280-46e7-bc25-748b07ef526d Poland (PL) | |
| Ordering | |
| E-Number (Finland) | 3641066 |
| EAN | 8015644021108 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.65 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 171 mm |
| Package Level 1 Height | 215 mm |
| Package Level 1 Depth / Length | 151 mm |
| Package Level 1 Gross Weight | 2.1 kg |
| Package Level 1 EAN | 8015644021108 |
| Additional Information | |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Breaking Part |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Version | F |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| Instructions and Manuals | 1SDH000722R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |