1SDA068126R1 ABB XT4N 250 Ekip LS/I In 250A 3p F F functions as a molded case circuit breaker designed to safeguard electrical distribution systems from overloads and short circuits in commercial environments. It ensures reliable interruption of fault currents to protect connected machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 56.30 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2352
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108469A1858
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 1dd7727d-27ac-42c4-a94d-75ca6cbb30d0 Italy (IT)
- Simplified SCIP: 27b6049b-8ce7-4140-8676-83d45397946d Germany (DE)
- Order Code US and Canada: XT4NE3250EFF000XXX
- E-Number (Finland): 3638175
- E-Number (Sweden): 3182043
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2352 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1858 |
| 9AKK108468A1898 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 1dd7727d-27ac-42c4-a94d-75ca6cbb30d0 Italy (IT) |
| Simplified SCIP | 27b6049b-8ce7-4140-8676-83d45397946d Germany (DE) |
| 9200176c-46dc-483e-b753-48f4a12f9b46 Netherlands (NL) | |
| 20abc35f-3e0e-438f-b19e-b129837db3f7 Estonia (EE) | |
| 09a4c37e-dd07-4ada-ae03-5526ee91f745 Greece (GR) | |
| 636a5cf7-6567-494d-9615-8f0ca9cfd339 Portugal (PT) | |
| 2a8a854e-80f3-4c6d-9b74-edc0002e0b43 Bulgaria (BG) | |
| 62a6510f-aa0a-47ad-90bc-43ea02213247 Sweden (SE) | |
| 71256522-48e3-4f83-bf29-ec69092af45a Poland (PL) | |
| e6850370-8a20-44dc-8116-8ec8949a32af Germany (DE) | |
| 315c8a3b-870a-4c23-b549-36cf82052322 Denmark (DK) | |
| b6b8fa4c-fbf3-4b01-8de0-aa23992318ae Germany (DE) | |
| 162d16e2-8f71-4c34-8a7f-23d6c3b27841 Croatia (HR) | |
| 12fe68a7-cf34-4e41-aa3b-29ca76c07dd5 Czech Republic (CZ) | |
| 92650768-ebe7-40de-9737-373f3fd64cf3 Poland (PL) | |
| d1caeb7e-b751-4be9-8a89-8a133eadcfdb Netherlands (NL) | |
| 98d6d3e7-0583-41ce-ba15-1cb47d852fa8 France (FR) | |
| 63efd85a-04c1-4f3a-937e-caa3f01ee671 Sweden (SE) | |
| 08462d36-e651-4155-9a05-5aade01a855a Germany (DE) | |
| e934b426-3eb4-4f7a-95e1-735388cd8268 Germany (DE) | |
| bbf84e3e-7bd3-4699-a859-b3c51fde7316 France (FR) | |
| cee32117-862f-4427-a9eb-5811cfdafc62 Netherlands (NL) | |
| b2317c81-c8f3-48f0-95e2-c8e9926a228b Spain (ES) | |
| ae59186a-1078-40fc-b246-cc9e79a7b343 Netherlands (NL) | |
| ec1c3816-e8e0-443b-9cad-a4a925cadb96 Poland (PL) | |
| bad0e3c6-ef27-47be-aac6-2207cadc0140 Norway (NO) | |
| 54b940eb-7dba-40ce-9298-2692251e14de Finland (FI) | |
| cd297300-7723-4a35-a0d1-cd5e2b49e7d6 Netherlands (NL) | |
| Ordering | |
| Order Code US and Canada | XT4NE3250EFF000XXX |
| E-Number (Finland) | 3638175 |
| E-Number (Sweden) | 3182043 |
| EAN | 8015644020231 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 2.312 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 151 mm |
| Package Level 1 Height | 214 mm |
| Package Level 1 Depth / Length | 171 mm |
| Package Level 1 Gross Weight | 2.434 kg |
| Package Level 1 EAN | 8015644020231 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 85..200 mm² |
| Current Type | AC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 16.4 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 250 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Recommended Screw Driver | Main Circuit M8 |
| Release | Ekip Dip LS/I |
| Release Type | EL |
| RoHS Date | NA |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1003 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000722R0100 |
| Mechanical Drawings | 1SDH000722R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000722R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |