View larger
1SDA068175R1 ABB XT4H250 PART OF INTERRUPTION 3P F F
1SDA068175R1
068175
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A molded case circuit breaker accessory or frame part, represented by the Abb 1SDA068175R1 ABB XT4H250 PART OF INTERRUPTION 3P F F model, is utilized within modular electrical protection assemblies to configure customized breaking capacities. Such structural elements allow technicians to build out tailored switchgear configurations suited for complex industrial power control requirements. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 56.30 %
- End of Life Instructions: 9AKK108468A2351
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Environmental Information: 9AKK108467A6707
- Environmental Product Declaration - EPD: 9AKK108469A1857
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- E-Number (Finland): 3641086
- EAN: 8015644696191
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| End of Life Instructions | 9AKK108468A2351 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Environmental Information | 9AKK108467A6707 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1857 |
| 9AKK108468A1892 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Ordering | |
| E-Number (Finland) | 3641086 |
| EAN | 8015644696191 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.65 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 171 mm |
| Package Level 1 Height | 215 mm |
| Package Level 1 Depth / Length | 151 mm |
| Package Level 1 Gross Weight | 2.1 kg |
| Package Level 1 EAN | 8015644696191 |
| Additional Information | |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Breaking Part |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 15 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 15 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Version | F |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 2CDC210017C0101 |
| 1SDC210100D0206 | |
| 1SXF210033C2001 | |
| 1SDC210099D0206 | |
| 1SXF210034C2001 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| Wiring Diagram | |
| Instructions and Manuals | 1SDH000722R0001 |
| Classifications | |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |