View larger
1SDA068345R1 ABB XT4H 250 TMA 250-2500 3p F F
1SDA068345R1
068345
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A moulded case circuit breaker, represented by the Abb 1SDA068345R1 ABB XT4H 250 TMA 250-2500 3p F F, is installed in electrical switchgear to isolate circuits during overloads and short circuits. It acts as an automatic switch that interrupts abnormal electrical flows to protect downstream machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2351
- Environmental Product Declaration - EPD: 9AKK108469A1857
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 56.30 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 62f9b351-ae79-4e9f-bcc2-3128e3e2c068 Italy
- Simplified SCIP: a666ddee-2f0c-4cc9-b780-45990b58daf1 France
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT4HE3250BFF000XXX
- E-Number (Finland): 3638098
- E-Number (Norway): 4379904
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2351 |
| Environmental Product Declaration - EPD | 9AKK108469A1857 |
| 9AKK108468A1892 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 62f9b351-ae79-4e9f-bcc2-3128e3e2c068 Italy |
| Simplified SCIP | a666ddee-2f0c-4cc9-b780-45990b58daf1 France |
| 5fc8293e-1254-426f-9c08-917a0fefa1c9 Hungary | |
| d8363695-6bd4-4b93-8d7f-704aba26987e Spain | |
| 55a55b89-0a86-4b66-b799-b2bebeefd9a5 Belgium | |
| 2cdfac74-28b9-410f-b447-ebe0790a78bb Portugal | |
| 89f82776-1052-4d91-b549-432bed4af6f6 Sweden | |
| c1ad9aab-0fca-489c-9bd8-cc6858c73e3a Denmark | |
| 2194f03c-206b-421b-b48b-255f38b3c7f9 Germany | |
| 439d606c-53fe-4d76-a049-2d99d573e5d5 Croatia | |
| 00d22dac-8573-4a2d-977e-f5bade8ed752 Germany | |
| 39696282-b1ab-4610-9a36-89952adc2c23 Germany | |
| e00cab3c-82ee-4441-b67b-600e947eddce Czech Republic | |
| 5aa5b7db-121e-4b67-b890-f3b0463595ef Finland | |
| 5ef4a016-2cc4-40cb-a478-ac96c72429fc Germany | |
| 8ffbe887-725b-4704-99a2-f93c232b6f95 Poland | |
| 694e7183-4ac1-4a13-a8b3-ee80f93c0f8f Poland | |
| 24247938-7415-4855-ba4f-566e4fddbd73 Bulgaria | |
| 45c0fb37-15e5-4588-95ae-711e85044975 Sweden | |
| 265478ed-ed1e-4409-9c0c-8b81cbff4d50 Netherlands | |
| efdc7c30-8fe1-4ecf-b929-3fe26ce7f5e1 Norway | |
| 51a1b38e-2881-4b85-85fc-e4df0031051c France | |
| d209594f-884f-433d-b226-c700b5339f11 Greece | |
| 9ab14d06-cec2-471c-98db-a78af23d27e0 Germany | |
| 6f10939e-fcef-4c3e-9de4-3554146772c9 Estonia | |
| db432cbc-16cf-4ee1-9d18-6a2cf39da8ec Belgium | |
| 17cad91e-24dc-4e76-8a9f-d98d82c8e84e Poland | |
| df9f87c4-e9c4-44a7-9ba9-df705883ce17 Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT4HE3250BFF000XXX |
| E-Number (Finland) | 3638098 |
| E-Number (Norway) | 4379904 |
| EAN | 8015644022518 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 2.253 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 151 mm |
| Package Level 1 Height | 214 mm |
| Package Level 1 Depth / Length | 171 mm |
| Package Level 1 Gross Weight | 2.386 kg |
| Package Level 1 EAN | 8015644022518 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1003 |
| Technical | |
| Connecting Capacity Main Circuit | Busbar 85..200 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3P |
| Opening Time | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 16.44 W |
| Rated Current (In) | 250 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 1250…2500 A |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 750 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 15 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 15 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M8 |
| Release | TMA |
| Release Type | TM |
| Setting Range | 175...250 A |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000722R0100 |
| Mechanical Drawings | 1SDH000722R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000722R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |