Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Protecting four-wire electrical circuits against overloads and short circuits, this ABB Tmax XT circuit breaker delivers robust performance in commercial and industrial power distribution. It ensures reliable fault interruption and circuit isolation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 56.30 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2352
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108469A1858
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 3bb58644-4021-46c9-8c76-ea986f557c17 Italy (IT)
- Simplified SCIP: 83002f30-43bf-4224-b616-5a3300cd69bb Germany (DE)
- Order Code US and Canada: XT4HE4250EFF000XXX
- EAN: 8015644024413
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2352 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1858 |
| 9AKK108468A1898 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 3bb58644-4021-46c9-8c76-ea986f557c17 Italy (IT) |
| Simplified SCIP | 83002f30-43bf-4224-b616-5a3300cd69bb Germany (DE) |
| d5867d7c-5e26-4570-b9b1-d293a3aa348f Poland (PL) | |
| 8d808279-45de-4986-8f73-6a84526ffe16 Norway (NO) | |
| 8f3638e9-ceae-4372-87e3-cea7a50a1e6f Finland (FI) | |
| ff438746-ae75-4883-817c-8a1390377452 Netherlands (NL) | |
| de178495-2fd9-46bd-b467-aab3f8e7776a Germany (DE) | |
| 9c0875c7-38c7-4598-add3-3381b9e104fc France (FR) | |
| ac7b38ac-e045-40f2-bf2a-e046e7712dbe Estonia (EE) | |
| 31986cf6-e6fd-42ff-9995-9d801e8fa818 Greece (GR) | |
| 4d5cf7df-343e-431a-b68a-81f9a6ff9a1e Portugal (PT) | |
| a7474e97-9eb0-4a35-b3a7-01ceb84568cf Bulgaria (BG) | |
| f2bb7e86-ff31-4d10-b817-707d88ae564f Sweden (SE) | |
| bc7ac611-c3bd-46b2-808e-b73d22fc459a Poland (PL) | |
| 48cad285-6ae3-442b-9855-d36bb5db710d Denmark (DK) | |
| ef24d103-0059-474b-a14c-b8cdb3b0d1e7 Germany (DE) | |
| 42188984-18f7-4773-b994-d9c00f5a69f3 Croatia (HR) | |
| c790cddd-65c6-45f6-8df4-c6b91dadcdaf Czech Republic (CZ) | |
| 693e7a3e-536b-4676-bddf-e8a1fd967acf Poland (PL) | |
| 58c798ae-4d7b-4c69-aacf-4924765f4676 Netherlands (NL) | |
| ce9a0f81-b4b1-4931-8f84-8643354223f4 Netherlands (NL) | |
| 1dc8f843-f6fa-49c9-8735-512986c5ce51 Sweden (SE) | |
| 7767267e-5ad6-4f7f-87af-b2a31387af48 Germany (DE) | |
| 48d8b3ab-5971-4eef-a40c-455075b4eaf3 Germany (DE) | |
| 0464a1d5-f3ae-4e29-a638-1248839198e0 France (FR) | |
| 6c86a4bc-6974-471d-a0d2-65b57ee79582 Netherlands (NL) | |
| 8b90fac3-8e38-48e3-b639-dc863860b82d Spain (ES) | |
| 1b7213fc-3a20-4e31-b5cd-f534ffb5e623 Netherlands (NL) | |
| Ordering | |
| Order Code US and Canada | XT4HE4250EFF000XXX |
| EAN | 8015644024413 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 2.933 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 151 mm |
| Package Level 1 Height | 214 mm |
| Package Level 1 Depth / Length | 171 mm |
| Package Level 1 Gross Weight | 3.087 kg |
| Package Level 1 EAN | 8015644024413 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 85..200 mm² |
| Current Type | AC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 4 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 16.4 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 250 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 15 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 15 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Recommended Screw Driver | Main Circuit M8 |
| Release | Ekip Dip LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0677 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000722R0100 |
| Mechanical Drawings | 1SDH000722R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000722R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |