Operating as a reliable molded case circuit breaker, this 1SDA067020R1 ABB XT2N 160 TMA 160-1600 3p F F protects electrical circuits by interrupting abnormal current levels and short circuits. It is standard in commercial and industrial distribution setups for safeguarding equipment. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 55.70 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2348
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108469A1856
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: d519e276-d4b0-4b42-8a55-c1a563681fc8 Italy (IT)
- Simplified SCIP: fe9c7b75-7199-4058-bd55-f39c45d837b1 Germany (DE)
- Order Code US and Canada: XT2NE3160BFF000XXX
- E-Number (Finland): 3638177
- EAN: 8015644009267
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.70 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2348 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1856 |
| 9AKK108468A1891 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | d519e276-d4b0-4b42-8a55-c1a563681fc8 Italy (IT) |
| Simplified SCIP | fe9c7b75-7199-4058-bd55-f39c45d837b1 Germany (DE) |
| a2e7e927-2395-4bdc-be8d-810d0cb0ae45 Portugal (PT) | |
| e89088df-21ed-4d26-b95c-a0480b45024d Bulgaria (BG) | |
| e5f2f46a-2fd6-4c7e-bb25-a46cf48987e3 France (FR) | |
| 6e917ee4-4216-40f5-a8a3-e310dc60dc70 Norway (NO) | |
| e5692b23-c0ac-4f4c-8b6c-d1ade35c30c2 Finland (FI) | |
| 45c61df3-6641-4084-81a3-7d93bafd3854 Netherlands (NL) | |
| 911050ef-ac90-4e21-b4b9-a662112db80f Spain (ES) | |
| 24003ffc-e1a5-47bb-a8b8-451202db8f05 Netherlands (NL) | |
| eda1b4f0-a70f-4d5d-9cd4-b12af82bd479 Poland (PL) | |
| 6a135342-7f65-41e7-bf92-aafb3e7dba8f Sweden (SE) | |
| e90f788c-8237-4208-bcbb-b57b6e8c6f34 Poland (PL) | |
| 6bde395d-b3ce-4547-bfe6-9d0f2acce853 Sweden (SE) | |
| 7baa1ff8-47fc-47fa-9a52-115afb224150 Germany (DE) | |
| 21953dfb-88b7-46f1-aef2-9ca2ee14f1ce Germany (DE) | |
| 80fdd440-e1f4-40c8-84f2-ebdf68d25284 France (FR) | |
| 7e70c592-6fe7-42ff-b672-c12bef9daa96 Netherlands (NL) | |
| ca62c6c8-a70f-4cc1-aaa4-dca46695e677 Germany (DE) | |
| cbc6c65f-2667-4430-9264-3c5c6ef91dd8 Denmark (DK) | |
| b8480e5f-7d16-408a-8c42-d667687e8b3c Germany (DE) | |
| d5a93a62-0ed3-46a8-bbb0-0a366c1f5015 Croatia (HR) | |
| 49681ffe-e667-4540-8372-39afd4cfc136 Czech Republic (CZ) | |
| 86caf239-3aec-4c05-be83-437f0192df0c Poland (PL) | |
| c2be7ce5-f3a1-4875-a255-24d9e26372b6 Netherlands (NL) | |
| c4510edb-e303-4d7c-a5e9-ec2994672c7b Netherlands (NL) | |
| 08c21b77-eaa8-4840-ad41-8c49aec664ef Estonia (EE) | |
| aeaa3db2-98c3-4a85-998b-8b9815801ce8 Greece (GR) | |
| Ordering | |
| Order Code US and Canada | XT2NE3160BFF000XXX |
| E-Number (Finland) | 3638177 |
| EAN | 8015644009267 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 90 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.4 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 130 mm |
| Package Level 1 Height | 208 mm |
| Package Level 1 Depth / Length | 145 mm |
| Package Level 1 Gross Weight | 1.657 kg |
| Package Level 1 EAN | 8015644009267 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 32.5..100 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 16.15 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 160 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 800…1600 A |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMA |
| Release Type | TM |
| RoHS Date | NA |
| Setting Range | 112...160 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT2 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1001 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5901 |
| GL Certificate | 1SDL000163R0093 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000721R0100 |
| Mechanical Drawings | 1SDH000721R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000721R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4927 >> Molded case circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121616 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |