An ABB molded case circuit breaker, part number 1SDA076535R1 ABB XT2H 160 MA 160 Im 960...2240 3p F F, is engineered for magnetic-only motor protection in industrial automation setups. These specialized switching units respond instantly to short-circuit events while leaving thermal overload management to dedicated motor starters.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 55.70 %
- End of Life Instructions: 9AKK108468A2348
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Environmental Information: 9AKK108467A6707
- Environmental Product Declaration - EPD: 9AKK108469A1856
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 76c3fb93-74c8-4c4f-8efa-c97be460d858 Italy (IT)
- Simplified SCIP: 6b0814c2-cbd4-4bba-b043-9c8858431d17 Germany (DE)
- Order Code US and Canada: XT2HE3160MFF000XXX
- EAN: 8015644812706
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.70 % |
| End of Life Instructions | 9AKK108468A2348 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Environmental Information | 9AKK108467A6707 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1856 |
| 9AKK108468A1891 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 76c3fb93-74c8-4c4f-8efa-c97be460d858 Italy (IT) |
| Simplified SCIP | 6b0814c2-cbd4-4bba-b043-9c8858431d17 Germany (DE) |
| 54af5d43-4c3c-4b0e-b1e6-c03baf65eb23 Norway (NO) | |
| 14ca9698-6954-4db9-9698-68b1f80e460b Finland (FI) | |
| 4e49d761-4b38-4abf-a927-b5fc76b9856a Poland (PL) | |
| 6351bbcb-0d43-42a7-a32e-6acf9b9d2cb2 Netherlands (NL) | |
| e2cc4a4e-fe52-42d4-8a3b-0e239da48580 Netherlands (NL) | |
| fc9a50eb-6ede-4e2c-b1a4-e8c496260a29 Netherlands (NL) | |
| bed26d31-0e8f-470e-8df4-d305af397ecc Germany (DE) | |
| ef3db785-4c53-4b72-b293-f2c8c44ddcf9 Denmark (DK) | |
| cd7633a2-2517-4107-a8dc-9b9fd0335b62 Germany (DE) | |
| 8c1a773b-3762-4555-88aa-646e6dcdf01a Croatia (HR) | |
| 212b2528-fb2b-4213-aa47-db45f5e6f1af Czech Republic (CZ) | |
| 23055d97-a8cb-43a8-aa87-c41931884c08 Poland (PL) | |
| 914d19d3-a38f-47cb-86a2-0585147d3975 Sweden (SE) | |
| 5a509ae0-2296-47c4-92d5-14b9b71a71bf Germany (DE) | |
| ffa22373-0db4-4c85-ae66-1ed620ea7c71 Germany (DE) | |
| 98c69e14-46d3-4534-9e3b-de2e8185c6e9 France (FR) | |
| fe1face4-e9a5-4c69-ad79-b1b01592d749 Netherlands (NL) | |
| 7cc34078-edb2-43f2-aa49-c4cc8178f33e Spain (ES) | |
| 2d432de3-333a-48f9-b4b6-a8cba6aa777b Greece (GR) | |
| b26107da-517a-4817-bea6-cef9beb729b9 Portugal (PT) | |
| b6673167-654d-405f-9d22-aef7e7be07a6 Bulgaria (BG) | |
| 61e7b878-412f-437a-978b-8ce6c02d702a Sweden (SE) | |
| 0de66c90-3c44-4eec-b027-affd2d08e626 Poland (PL) | |
| ad513e3d-793c-4016-9bf1-e7853b63107b France (FR) | |
| 12134684-bfb6-4931-abcf-5d602e8d2cc8 Netherlands (NL) | |
| b7f787ec-c3b4-4205-aaf6-7242451d9221 Estonia (EE) | |
| Ordering | |
| Order Code US and Canada | XT2HE3160MFF000XXX |
| EAN | 8015644812706 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 90 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.4 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 130 mm |
| Package Level 1 Height | 208 mm |
| Package Level 1 Depth / Length | 145 mm |
| Package Level 1 Gross Weight | 1.638 kg |
| Package Level 1 EAN | 8015644812706 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Motor Protection |
| Connecting Capacity Main Circuit | Busbar 32.5..100 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 16.15 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 160 A |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 960…2240 A |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 15 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 15 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M6 |
| Release | MA |
| Release Type | M |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT2 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1001 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5901 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000721R0100 |
| Mechanical Drawings | 1SDH000721R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000721R0001 |
| Classifications | |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers |
| Object Classification Code | Q |
| UNSPSC | 39121616 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |