View larger
1SDA067901R1 ABB XT2H160 Ekip I R160 4P F F
1SDA067901R1
067901
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for robust electrical system protection, the Abb 1SDA067901R1 ABB XT2H160 Ekip I R160 4P F F circuit breaker safely interrupts fault currents and isolates power distribution circuits. These units are deployed in industrial panels to prevent damage from overcurrent events and short circuits.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2349
- Environmental Product Declaration - EPD: 9AKK108469A1855
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 55.70 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 70ade39c-ddb4-4f38-9b7b-d7730e831689 China
- Simplified SCIP: bca1b764-d908-4e80-8ea8-b8f971892c7b France
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT2HE4160JFF000XXX
- E-Number (Norway): 4379702
- EAN: 8015644017972
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2349 |
| Environmental Product Declaration - EPD | 9AKK108469A1855 |
| 9AKK108468A1897 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 55.70 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 70ade39c-ddb4-4f38-9b7b-d7730e831689 China |
| Simplified SCIP | bca1b764-d908-4e80-8ea8-b8f971892c7b France |
| 40dc5a66-b9cf-48a4-bd03-f2f9ba91a123 Bulgaria | |
| ace18fbd-7b9c-4f0a-927e-9301d94f56ae Germany | |
| 6b7a9f89-36fb-47fd-a7a2-a2bcd8e476b2 Poland | |
| f395d6ce-3680-4f6f-99a2-39a1b0024335 Sweden | |
| 9a06ff2f-fbfd-442a-a709-9aa07a72a5fa Portugal | |
| 95b3b446-9d5c-4932-9742-4cf66e94b355 Greece | |
| 6fbc3ac1-520b-4180-9c85-548e21671c0b Estonia | |
| a54800d6-a7af-46fd-8442-a76fe29526c7 Germany | |
| fde90b45-c468-4eb9-a9d7-de389a1610a0 Sweden | |
| 9e16cd30-9430-4016-9a80-aec744b35216 Belgium | |
| 25e79713-ad45-44f5-9565-d78fd4cb35bf Hungary | |
| 4947675b-285c-422b-bfb3-cce45973bb5a France | |
| 07755c31-0e46-49d0-b9a2-c5ed688f857f Spain | |
| 86379659-19db-4c5c-ab8a-8f17790465e4 Czech Republic | |
| ebf5666a-ca9e-426f-9cca-474adfa40a7e Poland | |
| 11a4660c-4946-4169-aeb1-6180642bae79 Hungary | |
| 6cc8416f-5d35-424b-84df-3a11db606f60 Netherlands | |
| afd777a3-5439-4c7d-a47d-85a5c66a6e90 Germany | |
| b4ebe6d8-6f6b-4ce0-9f8f-032f4cceefc8 Denmark | |
| 17627abe-c0df-4657-b7b3-acbf36cc05fe Germany | |
| ea5534d8-6f28-40bd-9dc1-5db47f962766 Belgium | |
| 09153ebb-7906-4570-80de-6e31befbe963 Finland | |
| c9bd3733-78dd-4b4e-b057-8724af5cadea Norway | |
| 6856bcbd-d98c-487a-99f7-aa5ae0e5feb2 Poland | |
| 409aa937-da2c-4bb3-ac25-4ca1922df4c2 Croatia | |
| 80d93bb3-f9a6-45aa-abdc-1c7a8d236250 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT2HE4160JFF000XXX |
| E-Number (Norway) | 4379702 |
| EAN | 8015644017972 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 120 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.6 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 130 mm |
| Package Level 1 Height | 208 mm |
| Package Level 1 Depth / Length | 145 mm |
| Package Level 1 Gross Weight | 1.6 kg |
| Package Level 1 EAN | 8015644017972 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1002 |
| Technical | |
| Connecting Capacity Main Circuit | Busbar 32.5..100 mm² |
| Current Type | AC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 4P |
| Opening Time | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 10.8 W |
| Rated Current (In) | 160 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 15 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 15 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M6 |
| Release | Ekip I |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT2 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5901 |
| GL Certificate | 1SDL000163R0093 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000721R0100 |
| Mechanical Drawings | 1SDH000721R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000721R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |