View larger
1SDA067436R1 ABB XT1S 160 TMD 160-1600 3p F F
1SDA067436R1
067436
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
XT1
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built for reliable circuit protection, the 1SDA067436R1 ABB XT1S 160 TMD 160-1600 3p F F acts as a molded case circuit breaker to interrupt electrical overcurrents and short circuits in industrial environments. Such components maintain system reliability and protect sensitive equipment from electrical faults. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2347
- Environmental Product Declaration - EPD: 9AKK108468A1890
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 55.9 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 68fc2d01-8259-4796-990c-6c9587ff56a0 Italy
- Simplified SCIP: de04ea43-1440-4188-bc5f-f634d10f8088 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT1SE3160AFF000XXX
- E-Number (Norway): 4309625
- EAN: 8015644013301
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2347 |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 68fc2d01-8259-4796-990c-6c9587ff56a0 Italy |
| Simplified SCIP | de04ea43-1440-4188-bc5f-f634d10f8088 Germany |
| bc5703e6-1622-465a-9ffa-3341b5960253 Poland | |
| 3b2b4297-97fd-4bf5-83a1-01f187e0792f Norway | |
| 4ac4b647-ef91-4e77-bf5f-ffcee266f743 Finland | |
| b28c462e-5167-4e4e-ac9f-5164576df572 Netherlands | |
| f180a750-8c0b-4a81-b4d9-e5acbd9ad6a5 Germany | |
| 2303f4a0-7022-425f-bcf7-2185bfc393d7 Denmark | |
| baca2440-267f-4905-95bf-9d344585ebcc Germany | |
| e685b272-7682-4c6d-87f1-a2b48b1808c4 Croatia | |
| 7d64b5a5-7b9a-4bfb-9b47-2ea5b61689e4 Czech Republic | |
| e557ea3c-2e49-4f2c-a864-d4659cd0b166 Poland | |
| 2b0a2eb9-ae84-47d2-83fa-3e927d320838 Netherlands | |
| 2ad570a8-d3a4-4d6b-8750-2ac8a26eb055 Netherlands | |
| ea0810a6-63e0-4e2e-b8d0-ae2183252250 Estonia | |
| e3d65991-dc56-43c4-8d9b-c8d1a678b275 Greece | |
| cda31a1b-a7ed-4573-951e-9677c1ba4bec Portugal | |
| c72ec0a5-670c-4059-b5d9-9c6f30d6637b Sweden | |
| 01e0ca48-0b57-4a74-8aa8-0521daf4553a Germany | |
| 766cc5c4-41d5-448c-8b49-7ae5efaa5a63 Germany | |
| 30c8be75-771e-4380-958b-de7af2140296 France | |
| de6cfc88-5d61-4fd9-b89b-c482e19f665a Netherlands | |
| ade641dd-95e0-4bbf-bc40-df8ce463c69e Spain | |
| 37fc1530-8d78-4fd6-ad1b-bf19c4260e9b Netherlands | |
| e0db57b8-ed68-40e0-b769-9a9194f2dea8 Bulgaria | |
| d09160ca-e58e-4a3f-a740-84e2891efbf0 Sweden | |
| 37fc1530-8d78-4fd6-ad1b-bf19c4260e9b Netherlands | |
| 06272e1e-0fb2-4dd0-b0b1-79d36d2ffa8a Poland | |
| 274bcc65-417f-4283-905e-6ff982930097 France | |
| c72ec0a5-670c-4059-b5d9-9c6f30d6637b Sweden | |
| 01e0ca48-0b57-4a74-8aa8-0521daf4553a Germany | |
| 766cc5c4-41d5-448c-8b49-7ae5efaa5a63 Germany | |
| 30c8be75-771e-4380-958b-de7af2140296 France | |
| de6cfc88-5d61-4fd9-b89b-c482e19f665a Netherlands | |
| ade641dd-95e0-4bbf-bc40-df8ce463c69e Spain | |
| bc5703e6-1622-465a-9ffa-3341b5960253 Poland | |
| 3b2b4297-97fd-4bf5-83a1-01f187e0792f Norway | |
| 4ac4b647-ef91-4e77-bf5f-ffcee266f743 Finland | |
| b28c462e-5167-4e4e-ac9f-5164576df572 Netherlands | |
| f180a750-8c0b-4a81-b4d9-e5acbd9ad6a5 Germany | |
| 2303f4a0-7022-425f-bcf7-2185bfc393d7 Denmark | |
| baca2440-267f-4905-95bf-9d344585ebcc Germany | |
| e685b272-7682-4c6d-87f1-a2b48b1808c4 Croatia | |
| 7d64b5a5-7b9a-4bfb-9b47-2ea5b61689e4 Czech Republic | |
| e557ea3c-2e49-4f2c-a864-d4659cd0b166 Poland | |
| 2b0a2eb9-ae84-47d2-83fa-3e927d320838 Netherlands | |
| 2ad570a8-d3a4-4d6b-8750-2ac8a26eb055 Netherlands | |
| ea0810a6-63e0-4e2e-b8d0-ae2183252250 Estonia | |
| e3d65991-dc56-43c4-8d9b-c8d1a678b275 Greece | |
| cda31a1b-a7ed-4573-951e-9677c1ba4bec Portugal | |
| e0db57b8-ed68-40e0-b769-9a9194f2dea8 Bulgaria | |
| d09160ca-e58e-4a3f-a740-84e2891efbf0 Sweden | |
| 06272e1e-0fb2-4dd0-b0b1-79d36d2ffa8a Poland | |
| 274bcc65-417f-4283-905e-6ff982930097 France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT1SE3160AFF000XXX |
| E-Number (Norway) | 4309625 |
| EAN | 8015644013301 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 76.2 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.173 kg |
| Package Level 1 EAN | 8015644013301 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0008 |
| Technical | |
| Connecting Capacity Main Circuit | Busbar 45.5 ... 80 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3P |
| Opening Time | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 15 W |
| Rated Current (In) | 160 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 1600 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 80 kA |
| (230 V AC) 80 kA | |
| (240 V AC) 80 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 37.5 kA | |
| (440 V AC) 25 kA | |
| (500 V AC) 18 kA | |
| (525 V AC) 17.5 kA | |
| (690 V AC) 5 kA | |
| (250 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 3 Poles in Series 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 35 kA | |
| (690 V AC) 8 kA | |
| (250 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 3 Poles in Series 50 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMD |
| Release Type | TM |
| Setting Range | 112...160 A |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| GL Certificate | 1SDL000163R0103 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000719R0100 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |