Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Identified by code 1SDA080827R1, the ABB XT1N 160 TMF R16 Im450 3p F F serves as a compact molded case circuit breaker designed for general electrical protection. These units are commonly deployed in sub-distribution boards to guard against overcurrent and short-circuit faults in commercial and industrial settings.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 55.9 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2347
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108468A1890
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: bab57cb4-245d-44be-bf03-c5b43170495f Italy (IT)
- Simplified SCIP: 0ff67b66-9393-4f4b-8f5f-a17f64d2be5d Finland (FI)
- Order Code US and Canada: XT1NE3016AFF000XXX
- E-Number (Finland): 3640531
- EAN: 8015644873455
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2347 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | bab57cb4-245d-44be-bf03-c5b43170495f Italy (IT) |
| Simplified SCIP | 0ff67b66-9393-4f4b-8f5f-a17f64d2be5d Finland (FI) |
| 33253106-5ca0-4526-9533-bdadea09e443 Hungary (HU) | |
| 498f8cb1-1144-4233-b2da-7f77194abdaa France (FR) | |
| bed42174-22d5-44c5-825f-930a509434d9 Spain (ES) | |
| c1e394ba-ae25-477b-b7eb-41d9bf76e9e1 Belgium (BE) | |
| e0dac05e-e1bd-4d4d-9b78-cd7f3819e5b2 Germany (DE) | |
| 3de44331-1772-443c-92d5-420b325fac62 Czech Republic (CZ) | |
| b93fbbdb-806b-4f85-ad2e-e80a1115ec1a Croatia (HR) | |
| 15fbfd28-b2e7-4b5d-a137-b6f169f1de24 Germany (DE) | |
| 4051a5d0-7a42-4fde-822b-ab36eacae1e5 Sweden (SE) | |
| f5024ea2-de39-45f6-aea7-22a156c7bcd4 Germany (DE) | |
| 7766981b-f293-417d-8b77-4664d575a931 Denmark (DK) | |
| 90530b91-c871-4067-8c24-b38668043f31 Germany (DE) | |
| 8b716e70-3566-446c-a452-4d7d4fa36d8b Hungary (HU) | |
| 5f241e40-ba8d-46ac-9bee-578c560ace2e Portugal (PT) | |
| b24c2a99-4952-4ac7-b469-2dc063c115f3 Poland (PL) | |
| 22cf4870-2a6b-418e-99b6-5478ece1d46d Bulgaria (BG) | |
| fa4c15fc-e5c5-49de-bc87-f0352eb68ef8 Poland (PL) | |
| ba3f723e-560c-46ec-a4d5-2528743cbf58 Germany (DE) | |
| 91044a1f-bf91-4a05-a740-a940a4d580a9 Greece (GR) | |
| fc389803-df5d-4fc1-899f-ec9386da37c6 France (FR) | |
| b73a9713-b996-43fe-8b64-b301598e1df4 Estonia (EE) | |
| 96aa8a9b-18fb-4323-abe1-c46b4a275506 Belgium (BE) | |
| 8a6089c7-f76b-47ab-a558-5b3e91f2160f Norway (NO) | |
| c4f93059-ee47-47ae-87ca-6196e662f86b Sweden (SE) | |
| ccd75dfb-28c8-4a3c-8c48-6b229ce02d1b Netherlands (NL) | |
| 3f24730a-504f-4421-ab70-11492729f4ec Poland (PL) | |
| Ordering | |
| Order Code US and Canada | XT1NE3016AFF000XXX |
| E-Number (Finland) | 3640531 |
| EAN | 8015644873455 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 76.2 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.1 kg |
| Package Level 1 EAN | 8015644873455 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 16 A |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 450 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (240 V AC) 50 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 18 kA | |
| (500 V AC) 15 kA | |
| (525 V AC) 11 kA | |
| (690 V AC) 5 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 22 kA | |
| (690 V AC) 6 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Release | TMF |
| Release Type | TM |
| Setting Range | 16 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0008 |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |