View larger
1SDA080827R1
080827
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2347 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | bab57cb4-245d-44be-bf03-c5b43170495f Italy (IT) |
| Simplified SCIP | 0ff67b66-9393-4f4b-8f5f-a17f64d2be5d Finland (FI) |
| 33253106-5ca0-4526-9533-bdadea09e443 Hungary (HU) | |
| 498f8cb1-1144-4233-b2da-7f77194abdaa France (FR) | |
| bed42174-22d5-44c5-825f-930a509434d9 Spain (ES) | |
| c1e394ba-ae25-477b-b7eb-41d9bf76e9e1 Belgium (BE) | |
| e0dac05e-e1bd-4d4d-9b78-cd7f3819e5b2 Germany (DE) | |
| 3de44331-1772-443c-92d5-420b325fac62 Czech Republic (CZ) | |
| b93fbbdb-806b-4f85-ad2e-e80a1115ec1a Croatia (HR) | |
| 15fbfd28-b2e7-4b5d-a137-b6f169f1de24 Germany (DE) | |
| 4051a5d0-7a42-4fde-822b-ab36eacae1e5 Sweden (SE) | |
| f5024ea2-de39-45f6-aea7-22a156c7bcd4 Germany (DE) | |
| 7766981b-f293-417d-8b77-4664d575a931 Denmark (DK) | |
| 90530b91-c871-4067-8c24-b38668043f31 Germany (DE) | |
| 8b716e70-3566-446c-a452-4d7d4fa36d8b Hungary (HU) | |
| 5f241e40-ba8d-46ac-9bee-578c560ace2e Portugal (PT) | |
| b24c2a99-4952-4ac7-b469-2dc063c115f3 Poland (PL) | |
| 22cf4870-2a6b-418e-99b6-5478ece1d46d Bulgaria (BG) | |
| fa4c15fc-e5c5-49de-bc87-f0352eb68ef8 Poland (PL) | |
| ba3f723e-560c-46ec-a4d5-2528743cbf58 Germany (DE) | |
| 91044a1f-bf91-4a05-a740-a940a4d580a9 Greece (GR) | |
| fc389803-df5d-4fc1-899f-ec9386da37c6 France (FR) | |
| b73a9713-b996-43fe-8b64-b301598e1df4 Estonia (EE) | |
| 96aa8a9b-18fb-4323-abe1-c46b4a275506 Belgium (BE) | |
| 8a6089c7-f76b-47ab-a558-5b3e91f2160f Norway (NO) | |
| c4f93059-ee47-47ae-87ca-6196e662f86b Sweden (SE) | |
| ccd75dfb-28c8-4a3c-8c48-6b229ce02d1b Netherlands (NL) | |
| 3f24730a-504f-4421-ab70-11492729f4ec Poland (PL) | |
| Ordering | |
| Order Code US and Canada | XT1NE3016AFF000XXX |
| E-Number (Finland) | 3640531 |
| EAN | 8015644873455 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 76.2 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.1 kg |
| Package Level 1 EAN | 8015644873455 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 16 A |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 450 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (240 V AC) 50 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 18 kA | |
| (500 V AC) 15 kA | |
| (525 V AC) 11 kA | |
| (690 V AC) 5 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 22 kA | |
| (690 V AC) 6 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Release | TMF |
| Release Type | TM |
| Setting Range | 16 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0008 |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |