View larger
1SDA067420R1 ABB XT1N 160 TMD 40-450 4p F F
1SDA067420R1
067420
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
XT1
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This hardware is an ABB XT1N 160 TMD 40-450 4p F F molded case circuit breaker, designed to protect electrical sub-circuits from overloads and short circuits. Installers utilize compact 4-pole breakers like this across commercial buildings and manufacturing plants for reliable circuit isolation. Complete reference details are listed below.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 55.9 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2347
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108468A1890
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: bb45f1da-8cc1-46d6-83b6-a1b3baf6ac67 Italy (IT)
- Simplified SCIP: 06a16227-9a23-4383-a0e5-7b7175dca117 Belgium (BE)
- Order Code US and Canada: XT1NE4040AFF000XXX
- E-Number (Finland): 3640540
- EAN: 8015644013141
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2347 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | bb45f1da-8cc1-46d6-83b6-a1b3baf6ac67 Italy (IT) |
| Simplified SCIP | 06a16227-9a23-4383-a0e5-7b7175dca117 Belgium (BE) |
| e56b0d92-46c4-4721-970f-3af3b889864e Spain (ES) | |
| 0fc7925a-dcc0-4543-9d65-15d0e9522adb France (FR) | |
| 6d3efead-2c74-4337-8835-080e289b47a4 Germany (DE) | |
| d23204a9-469f-4a2e-a9c1-81106c28d8cd Czech Republic (CZ) | |
| dd717899-506f-4f7c-8d96-b08a31f29bda Croatia (HR) | |
| 95ca9790-495b-479b-8d24-2348be24b5cc Germany (DE) | |
| fefd45ff-5354-4cb5-9ee8-8fd8e9e845e6 Denmark (DK) | |
| a8c86710-5d69-43e7-953c-796232bdbcd1 Germany (DE) | |
| 624a7f18-ebf7-436d-88ca-75a07a63c7ab Sweden (SE) | |
| 586a90a7-18f8-455d-98a8-f4e432b26fe3 Poland (PL) | |
| 8e60a9c0-db05-4620-8a18-6ab9d9a3be1e Estonia (EE) | |
| 3c533264-addc-44ac-8251-fb304cb503b6 Greece (GR) | |
| 95a52950-6026-4eaf-a420-63e651313792 Belgium (BE) | |
| f9c309e9-d281-4301-879a-417a66bdbd5c Germany (DE) | |
| 1ac3a81d-e4cc-451d-946f-5bce449aa7cf France (FR) | |
| 2612acbc-c08b-4c40-9ed5-59287e2be748 Poland (PL) | |
| fe69ad38-e8e0-47bc-a9b7-3c53b49672ae Hungary (HU) | |
| 82760656-0550-4b3a-84bc-25a3f98b5c9e Portugal (PT) | |
| bbd1646d-d373-4851-bb91-b2ff51bf9de0 Germany (DE) | |
| b0598f26-f85c-4e4d-97cf-1274950ae30b Sweden (SE) | |
| cf070818-0ede-42d5-b70a-9bb9b0e27a41 Netherlands (NL) | |
| 5d2d773d-1c51-4406-8052-2af850322ac6 Norway (NO) | |
| baba48c7-474d-4919-9638-cff3a8cb00cc Hungary (HU) | |
| 7268b0d5-b5bf-4500-b2ef-13fc5aea72b8 Finland (FI) | |
| 8a4bcb19-74bc-4cb1-bd90-b1a712ead71c Bulgaria (BG) | |
| 843937e6-dbd9-4007-acff-baf15d2b4c44 Poland (PL) | |
| Ordering | |
| Order Code US and Canada | XT1NE4040AFF000XXX |
| E-Number (Finland) | 3640540 |
| EAN | 8015644013141 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 101.6 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.4 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.43 kg |
| Package Level 1 EAN | 8015644013141 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 45.5 ... 80 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 4 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 2.6 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 40 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 450 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (240 V AC) 50 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 18 kA | |
| (500 V AC) 15 kA | |
| (525 V AC) 11 kA | |
| (690 V AC) 5 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 22 kA | |
| (690 V AC) 6 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMD |
| Release Type | TM |
| Setting Range | 28...40 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0080 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| GL Certificate | 1SDL000163R0103 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000719R0100 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |