View larger
1SDA067454R1 ABB XT1H 160 TMD 160-1600 3p F F
1SDA067454R1
067454
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
XT1
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Acting as a reliable circuit protection device, this ABB XT1H 160 TMD 160-1600 3p F F molded case circuit breaker safeguards electrical installations from overcurrents and short-circuit faults. Commercial and industrial power distribution networks utilize these compact breakers within control panels to protect wiring and connected machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 55.9 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2347
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108468A1890
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 56dc0760-7ff8-4b75-9d5f-ff6578a7ed3c Italy (IT)
- Simplified SCIP: d65a073f-8b77-4a74-8b58-32965c3e4860 Germany (DE)
- Order Code US and Canada: XT1HE3160AFF000XXX
- EAN: 8015644013486
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2347 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 56dc0760-7ff8-4b75-9d5f-ff6578a7ed3c Italy (IT) |
| Simplified SCIP | d65a073f-8b77-4a74-8b58-32965c3e4860 Germany (DE) |
| 032431e7-74c1-4792-a618-890afb488afd Finland (FI) | |
| 759ddca3-f82b-486e-9d91-8a4ac696e5ca Netherlands (NL) | |
| 65ab0103-2ace-4738-acbe-95c32de0526e Germany (DE) | |
| 223d7a88-9ca2-4e97-9649-92816c9bfb44 Denmark (DK) | |
| 961f5b8c-1737-4f67-bf05-00875b7af6de Germany (DE) | |
| 21006405-1824-441f-9c2a-04c9b4ac1707 Croatia (HR) | |
| e752daa2-db69-4347-896a-7bda393b97b3 Czech Republic (CZ) | |
| b32b48ce-95bb-4dcd-997a-6afebaf90ed7 Poland (PL) | |
| ad0a4092-d03b-4f8a-9ad7-45fd8259d9d6 Netherlands (NL) | |
| 52b5fc70-823c-4bd8-a02c-076430b0ab20 Netherlands (NL) | |
| f3ce143f-3064-4bae-8a81-cfdc1332b00e Estonia (EE) | |
| 20cd1985-c18e-46de-9200-5a04a94702af Greece (GR) | |
| 203b540d-e425-4d35-b603-dd9bfd5c11f4 Portugal (PT) | |
| 92288c75-e02b-4b98-b63d-6fa0ffc64b75 Bulgaria (BG) | |
| 00c65cf2-036f-49fc-b0ff-bc1a2eb9fbd6 Sweden (SE) | |
| e1334ad5-59c5-459a-a19c-95060f2efc11 Poland (PL) | |
| 1ed72d8b-a527-4b45-b124-da06f39c6701 France (FR) | |
| 0f2adc46-473e-492a-8631-f2dd234a8690 Sweden (SE) | |
| 096c9316-10f8-4376-b34c-0636d6ea80cf Poland (PL) | |
| 1eb1a804-3aa1-4052-9ecf-da33ed02f810 Norway (NO) | |
| 032431e7-74c1-4792-a618-890afb488afd Finland (FI) | |
| 759ddca3-f82b-486e-9d91-8a4ac696e5ca Netherlands (NL) | |
| 65ab0103-2ace-4738-acbe-95c32de0526e Germany (DE) | |
| 223d7a88-9ca2-4e97-9649-92816c9bfb44 Denmark (DK) | |
| 961f5b8c-1737-4f67-bf05-00875b7af6de Germany (DE) | |
| 21006405-1824-441f-9c2a-04c9b4ac1707 Croatia (HR) | |
| e752daa2-db69-4347-896a-7bda393b97b3 Czech Republic (CZ) | |
| b32b48ce-95bb-4dcd-997a-6afebaf90ed7 Poland (PL) | |
| ad0a4092-d03b-4f8a-9ad7-45fd8259d9d6 Netherlands (NL) | |
| 52b5fc70-823c-4bd8-a02c-076430b0ab20 Netherlands (NL) | |
| f3ce143f-3064-4bae-8a81-cfdc1332b00e Estonia (EE) | |
| 20cd1985-c18e-46de-9200-5a04a94702af Greece (GR) | |
| 203b540d-e425-4d35-b603-dd9bfd5c11f4 Portugal (PT) | |
| b2745396-555f-4736-be90-e25a589824d5 Germany (DE) | |
| 9421f1af-98fd-4bbd-9d6b-32df84de604c Germany (DE) | |
| b35f29c4-17e0-41a1-b10a-47bd10b86f1c France (FR) | |
| 2ec3fe12-2674-4236-81ad-8956b61a80f8 Netherlands (NL) | |
| 777d5fd9-66c1-4e6f-b231-1f7e13ce8d6c Spain (ES) | |
| 01d66fad-659d-4f78-9d03-c053635df01f Netherlands (NL) | |
| 92288c75-e02b-4b98-b63d-6fa0ffc64b75 Bulgaria (BG) | |
| 00c65cf2-036f-49fc-b0ff-bc1a2eb9fbd6 Sweden (SE) | |
| 01d66fad-659d-4f78-9d03-c053635df01f Netherlands (NL) | |
| e1334ad5-59c5-459a-a19c-95060f2efc11 Poland (PL) | |
| 1ed72d8b-a527-4b45-b124-da06f39c6701 France (FR) | |
| 0f2adc46-473e-492a-8631-f2dd234a8690 Sweden (SE) | |
| b2745396-555f-4736-be90-e25a589824d5 Germany (DE) | |
| 9421f1af-98fd-4bbd-9d6b-32df84de604c Germany (DE) | |
| b35f29c4-17e0-41a1-b10a-47bd10b86f1c France (FR) | |
| 2ec3fe12-2674-4236-81ad-8956b61a80f8 Netherlands (NL) | |
| 777d5fd9-66c1-4e6f-b231-1f7e13ce8d6c Spain (ES) | |
| 096c9316-10f8-4376-b34c-0636d6ea80cf Poland (PL) | |
| 1eb1a804-3aa1-4052-9ecf-da33ed02f810 Norway (NO) | |
| Ordering | |
| Order Code US and Canada | XT1HE3160AFF000XXX |
| EAN | 8015644013486 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 76.2 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.18 kg |
| Package Level 1 EAN | 8015644013486 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 45.5 ... 80 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 15 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 160 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 1600 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 80 kA |
| (230 V AC) 80 kA | |
| (240 V AC) 80 kA | |
| (380 V AC) 52.5 kA | |
| (415 V AC) 37.5 kA | |
| (440 V AC) 32.5 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 17.5 kA | |
| (690 V AC) 5 kA | |
| (250 V DC) 2 Poles in Series 52.5 kA | |
| (500 V DC) 3 Poles in Series 52.5 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 35 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMD |
| Release Type | TM |
| Setting Range | 112...160 A |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0008 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| GL Certificate | 1SDL000163R0103 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000719R0100 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |