View larger
1SDA067391R1 ABB XT1C 160 TMD 25-450 3p F F
1SDA067391R1
067391
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
XT1
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 1SDA067391R1 ABB XT1C 160 TMD 25-450 3p F F is a molded case circuit breaker built for reliable electrical protection in commercial and industrial power distribution networks. These switching devices automatically disconnect faulty circuits to prevent equipment damage and protect personnel from electrical hazards. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 55.9 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2347
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108468A1890
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: db866913-fe89-4d27-9e19-1544af8a4f02 Italy (IT)
- Simplified SCIP: f202abe0-12ec-4179-97cf-89b315c6c305 Belgium (BE)
- Order Code US and Canada: XT1CE3025AFF000XXX
- E-Number (Finland): 3638773
- EAN: 8015644012151
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2347 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | db866913-fe89-4d27-9e19-1544af8a4f02 Italy (IT) |
| Simplified SCIP | f202abe0-12ec-4179-97cf-89b315c6c305 Belgium (BE) |
| 3d1fa375-8d2c-4fb5-beca-a263dfdbb827 Hungary (HU) | |
| 54b75992-3367-4791-b554-6dcbff2ab3cf Spain (ES) | |
| a27280a8-bca2-4b6a-b682-ae8b015e303e Greece (GR) | |
| f8cb45b8-f33d-4e6b-82a8-09008d3d5c87 France (FR) | |
| 575dd2dc-8960-4074-82bf-3f3a454ae5eb Germany (DE) | |
| 271e4ada-c178-46d8-aed4-cf3761368d48 Denmark (DK) | |
| 5fe60ea6-1acd-43a3-b6c0-21244ea6a92b Sweden (SE) | |
| 8ef0202e-998e-43d7-98b7-7e3bd879e073 Germany (DE) | |
| 79ff2322-f3e6-4a8d-b239-076d37b54fd2 France (FR) | |
| b27a41fe-5e2e-48d4-b833-8334bc466293 Germany (DE) | |
| e273ae3b-0922-414e-93c0-80847d9fdda3 Czech Republic (CZ) | |
| e963bee8-abc4-4c15-96b0-94965f6da5b1 Croatia (HR) | |
| 8d05a666-8814-4069-9dee-84b22f24a159 Germany (DE) | |
| 40ef665a-3599-439a-92b4-b97e5b6085cc Poland (PL) | |
| 7cae70a8-4172-4379-98ce-ff8f11f1c36f Poland (PL) | |
| 49d6c5fa-246b-46e4-b329-4b165daac59c Germany (DE) | |
| fa51e80d-bef3-49a2-af40-09ec71becb56 Portugal (PT) | |
| 29ebdc46-1142-4461-96f6-db3e960849ff Belgium (BE) | |
| ad417ab4-6c41-4c97-9ddd-ae123597879c Estonia (EE) | |
| f9c06e0e-932a-4471-a853-26b1015c0454 Poland (PL) | |
| fa1d5045-f5f1-4b1d-9ae6-a0a3df0c2bad Hungary (HU) | |
| daaa0f9a-041f-4888-be09-84b146fb9d05 Finland (FI) | |
| e790b803-9f89-4861-aafb-77ff28a18a26 Bulgaria (BG) | |
| a0187f54-10d1-4941-b25f-e7d1c73d8684 Norway (NO) | |
| 6ce47805-01dc-43b0-b9d7-a5185f82de42 Netherlands (NL) | |
| 85b2530f-01c1-49b5-b154-f7549e299333 Sweden (SE) | |
| Ordering | |
| Order Code US and Canada | XT1CE3025AFF000XXX |
| E-Number (Finland) | 3638773 |
| EAN | 8015644012151 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 76.2 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.124 kg |
| Package Level 1 EAN | 8015644012151 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 45.5 ... 80 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 2 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 25 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 450 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 40 kA |
| (230 V AC) 40 kA | |
| (240 V AC) 40 kA | |
| (380 V AC) 25 kA | |
| (415 V AC) 25 kA | |
| (440 V AC) 12.5 kA | |
| (500 V AC) 9 kA | |
| (525 V AC) 8 kA | |
| (690 V AC) 4 kA | |
| (250 V DC) 2 Poles in Series 25 kA | |
| (500 V DC) 3 Poles in Series 25 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 40 kA |
| (230 V AC) 40 kA | |
| (240 V AC) 40 kA | |
| (380 V AC) 25 kA | |
| (415 V AC) 25 kA | |
| (440 V AC) 25 kA | |
| (500 V AC) 18 kA | |
| (525 V AC) 8 kA | |
| (690 V AC) 4 kA | |
| (250 V DC) 2 Poles in Series 25 kA | |
| (500 V DC) 3 Poles in Series 25 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMD |
| Release Type | TM |
| RoHS Date | NA |
| Setting Range | 17.5...25 A |
| Short-Circuit Performance Level | C |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0008 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| GL Certificate | 1SDL000163R0103 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000719R0100 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |