View larger
1SDA067397R1 ABB XT1C 160 TMD 100-1000 3p F F
1SDA067397R1
067397
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
XT1
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Employed extensively in standard electrical distribution panels, the ABB XT1C 160 TMD 100-1000 3p F F molded case circuit breaker protects wiring systems and industrial machinery against overcurrent and short-circuit conditions. Such thermal-magnetic breakers offer dependable switching and circuit isolation for everyday industrial configurations.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 55.9 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2347
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108468A1890
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 9965ca99-affa-4173-b6ec-86c5b94f7e15 Italy (IT)
- Simplified SCIP: 0baf7834-5c1e-4ab6-92f8-fe1c0c18d111 Germany (DE)
- Order Code US and Canada: XT1CE3100AFF000XXX
- E-Number (Finland): 3638777
- EAN: 8015644012915
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2347 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 9965ca99-affa-4173-b6ec-86c5b94f7e15 Italy (IT) |
| Simplified SCIP | 0baf7834-5c1e-4ab6-92f8-fe1c0c18d111 Germany (DE) |
| 690bbaca-e914-49b1-b061-fadc8cb41754 Netherlands (NL) | |
| 1d9c93da-ce2a-496b-963a-5aa10a5952ea Netherlands (NL) | |
| faccd3ac-7bd6-452b-b339-f3e8650b7ed7 Germany (DE) | |
| 3971316a-abb7-4fb7-a3a4-b645aa241259 Denmark (DK) | |
| adf816cc-8afa-408f-b37f-84d38645b9ce Germany (DE) | |
| f57e9c1b-e394-43c6-92b6-24992fec4513 Croatia (HR) | |
| a23327a4-9935-4203-a9d5-741ba39df896 Czech Republic (CZ) | |
| b8b0676f-7b3e-4d5c-aa3c-7b6ebfe5bc3e Netherlands (NL) | |
| 678300f8-ecd0-4b74-8804-18f219da3ae0 Netherlands (NL) | |
| 2d166b04-bfde-406d-ae1b-a2d4f9a45c1f Estonia (EE) | |
| 769c0bf8-bb50-4b05-90d1-f148493e2e93 Greece (GR) | |
| c222885d-c4e3-48f8-aa94-67f29ec03c2e Portugal (PT) | |
| 0fa0c29c-f77e-4742-bd29-9f67a5dd58e7 Bulgaria (BG) | |
| 3a1ec757-f5bc-4fe2-a796-b80d5848b865 Sweden (SE) | |
| 3380a59b-f15a-4f8b-8fe2-54d228c70377 Poland (PL) | |
| 25e84eae-96f0-42ce-9d7d-9dfb5f5ce2a5 France (FR) | |
| dafbc307-d434-4abc-8c03-c64d3fc1c333 Sweden (SE) | |
| 3b414454-d89f-4090-bb59-470a3c7330ea Germany (DE) | |
| 59695450-664d-4372-9510-6f5c4ac5ad03 Germany (DE) | |
| 35ec2353-58cd-472a-b909-85aa064a6204 Spain (ES) | |
| 95a1642c-9a73-4d2e-8a1b-c20ad5fc8a6c Netherlands (NL) | |
| 5ec14cea-f544-4faa-ab16-fd3819a27732 Poland (PL) | |
| ca56bfe2-177d-4ed2-a416-d34db5ca5989 Poland (PL) | |
| 37ce67d3-3a1a-4ca0-b8ae-7bf5eec07bd9 Finland (FI) | |
| 3f937e08-97bb-4c73-ac98-fbbab57d1a84 Norway (NO) | |
| b394e0ce-ed58-41d4-9e52-9fc27c75e4e8 France (FR) | |
| Ordering | |
| Order Code US and Canada | XT1CE3100AFF000XXX |
| E-Number (Finland) | 3638777 |
| EAN | 8015644012915 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 76.2 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.136 kg |
| Package Level 1 EAN | 8015644012915 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 45.5 ... 80 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 7 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 100 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 1000 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 40 kA |
| (230 V AC) 40 kA | |
| (240 V AC) 40 kA | |
| (380 V AC) 25 kA | |
| (415 V AC) 25 kA | |
| (440 V AC) 12.5 kA | |
| (500 V AC) 9 kA | |
| (525 V AC) 8 kA | |
| (690 V AC) 4 kA | |
| (250 V DC) 2 Poles in Series 25 kA | |
| (500 V DC) 3 Poles in Series 25 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 40 kA |
| (230 V AC) 40 kA | |
| (240 V AC) 40 kA | |
| (380 V AC) 25 kA | |
| (415 V AC) 25 kA | |
| (440 V AC) 25 kA | |
| (500 V AC) 18 kA | |
| (525 V AC) 8 kA | |
| (690 V AC) 4 kA | |
| (250 V DC) 2 Poles in Series 25 kA | |
| (500 V DC) 3 Poles in Series 25 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMD |
| Release Type | TM |
| RoHS Date | NA |
| Setting Range | 70...100 A |
| Short-Circuit Performance Level | C |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0008 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| GL Certificate | 1SDL000163R0103 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000719R0100 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |