View larger
1SDA066804R1 ABB XT1B 160 TMD 50-500 3p F F
1SDA066804R1
066804
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
XT1
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb 1SDA066804R1 XT1B 160 TMD 50-500 3p F F is a compact molded case circuit breaker used to protect electrical circuits from overloads and short circuits in industrial and commercial distribution systems. These versatile protection devices ensure safe power delivery and allow manual or automatic disconnection during electrical faults. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2347
- Environmental Product Declaration - EPD: 9AKK108468A1890
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 55.9 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: a10a99fa-25ac-433d-b62d-7689b50c5c6c Italy
- Simplified SCIP: 41cd25de-2393-4a57-97ea-cc906e39537c Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT1BE3050AFF000XXX
- E-Number (Finland): 3640498
- E-Number (Norway): 4309605
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2347 |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | a10a99fa-25ac-433d-b62d-7689b50c5c6c Italy |
| Simplified SCIP | 41cd25de-2393-4a57-97ea-cc906e39537c Germany |
| 69cd6212-a899-4286-a772-8f474dc6c2bb Poland | |
| 37f17624-f471-4fd3-9b01-4c3625894ed3 Norway | |
| 4a34c8c8-9faf-4d2f-a59b-f51d5cdd4e8d Finland | |
| 5537a32c-26dc-4c9d-bc95-cb9905d66cfc Netherlands | |
| ef53c3b5-bc52-49fb-b855-7a8f21515267 Germany | |
| 56d03ad1-bd96-4376-9736-79e2ef64f4ab Denmark | |
| b3206c37-260c-4ebf-b240-4996b994f65d Germany | |
| ddb77a11-e6f5-4b70-bf76-a947793ddf48 Croatia | |
| 2c66013a-028e-4ca1-ac7d-2a830f47a45b Czech Republic | |
| 6dcf4af9-a40a-4f40-9d60-663b40bbfdc5 Poland | |
| 614bc1e9-9182-4efb-aa78-e6e9372fd979 Netherlands | |
| e9e72111-5dc6-449c-afad-bfb9bf049e48 Netherlands | |
| b9ea0014-b614-4eed-a49a-4a83d350ab8b Estonia | |
| f45570f0-233c-43c3-9f60-758b79f8fb85 Greece | |
| 2d3090e5-4296-4969-815a-fc359c86aeef Portugal | |
| ef329402-0bc6-458f-adc4-ca0f59af1e1c Bulgaria | |
| 025d7c1b-8c66-4efe-8e49-75d8efc43eba Sweden | |
| 5be09893-83ce-4487-b2ec-d9a313525d19 Poland | |
| fcfc9e57-aec8-4b59-a24d-f90af6d29625 France | |
| 338fd03f-9159-443a-9b5a-4a9e4e3be02e Sweden | |
| a0316fa6-51b1-46f4-ae1e-139caf62298e Germany | |
| 149a8272-3a2b-4d5c-8608-5789a28b417d Germany | |
| c4ea13ca-23b7-43e3-afbb-04d28a093f11 France | |
| 3e5bb53d-feda-4a12-a764-6f9cf645e4c7 Netherlands | |
| 513eef80-bdee-472a-815e-31c738e5c4da Spain | |
| bff7649f-dcc0-4167-b394-414dac45600a Netherlands | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT1BE3050AFF000XXX |
| E-Number (Finland) | 3640498 |
| E-Number (Norway) | 4309605 |
| EAN | 8015644007119 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 76.2 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.134 kg |
| Package Level 1 EAN | 8015644007119 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0008 |
| Technical | |
| Connecting Capacity Main Circuit | Busbar 45.5 ... 80 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3P |
| Opening Time | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 3.7 W |
| Rated Current (In) | 50 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 500 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 25 kA |
| (230 V AC) 25 kA | |
| (240 V AC) 25 kA | |
| (380 V AC) 18 kA | |
| (415 V AC) 18 kA | |
| (440 V AC) 11.25 kA | |
| (500 V AC) 8 kA | |
| (525 V AC) 6 kA | |
| (690 V AC) 3 kA | |
| (250 V DC) 2 Poles in Series 18 kA | |
| (500 V DC) 3 Poles in Series 18 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 25 kA |
| (230 V AC) 25 kA | |
| (240 V AC) 25 kA | |
| (380 V AC) 18 kA | |
| (415 V AC) 18 kA | |
| (440 V AC) 15 kA | |
| (500 V AC) 8 kA | |
| (525 V AC) 6 kA | |
| (690 V AC) 3 kA | |
| (250 V DC) 2 Poles in Series 18 kA | |
| (500 V DC) 3 Poles in Series 18 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMD |
| Release Type | TM |
| Setting Range | 35...50 A |
| Short-Circuit Performance Level | B |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| GL Certificate | 1SDL000163R0103 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000719R0100 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |