Request QuoteProduct Overview
Identified by part number 1SDA066808R1, the ABB XT1B 160 TMD 125-1250 3p F F acts as a molded case circuit breaker designed to manage and protect low-voltage electrical distribution circuits. Facility technicians install these compact switching devices to automatically disconnect power during overload or short-circuit events, preventing equipment damage.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2347
- Environmental Product Declaration - EPD: 9AKK108468A1890
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 55.9 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 6774955b-d880-4def-9c74-19a93e0bae4c Italy
- Simplified SCIP: c9218e91-3702-48c7-bafc-2a74747ba1b2 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT1BE3125AFF000XXX
- E-Number (Finland): 3640496
- E-Number (Norway): 4309609
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2347 |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 6774955b-d880-4def-9c74-19a93e0bae4c Italy |
| Simplified SCIP | c9218e91-3702-48c7-bafc-2a74747ba1b2 Germany |
| 0d2150b0-2b95-48d1-ab50-aaa310de7cb0 Poland | |
| cee9d778-423b-4301-9f27-16e26d8be184 Norway | |
| 6b8f38c8-1ec2-4c2b-beeb-31ed145d161d Finland | |
| dcaf512d-d6f7-4e34-8d7c-982d94a7f49c Netherlands | |
| 97a89143-ee64-45d0-a21b-cfae8450263a Germany | |
| 2f5e5e2f-ab8d-4466-a2bd-3cb87ff7223e Denmark | |
| 2a4f90b7-7165-43c0-87f0-06e205cbb250 Germany | |
| 556152b5-5ed1-4bb6-90d2-a8846f692834 Croatia | |
| 5d2ea5a0-3812-4d07-bc83-e7557e2c20cd Czech Republic | |
| 340d33d7-db60-4da5-8988-3d97adf34e40 Poland | |
| 6f662a23-c2f2-45aa-8b67-7622964ab8e6 Netherlands | |
| c6796a85-e78d-406b-86fd-9d50ed361761 Netherlands | |
| 642eed60-ab43-438e-b29b-d2b83a1d1d0a Estonia | |
| 710d4b07-1223-4202-8a2a-8f2c8a75f77e Greece | |
| 27624ad5-a53c-4371-b226-08015a416947 Portugal | |
| 36b5dfe7-336d-4134-952e-28633cf67e81 Bulgaria | |
| 37bea7dc-eb4c-4a6d-a626-31b8e1a6ac35 Sweden | |
| 8e83dd65-51f4-470f-a07f-c2e48c91cd0c Poland | |
| c5e5f6cf-d260-44c6-aac5-44b3514c85b0 France | |
| 247f3a3c-b0a8-42bf-aae0-452961210a71 Sweden | |
| 635ad7c9-532f-4f1d-a1a1-5137b6daac93 Germany | |
| 1ecf956f-f5a6-4ebb-b28c-be0db3d867c8 Germany | |
| f525384a-8929-44a6-aa0d-3ea572ba0573 France | |
| 360273d7-50aa-43b3-8eef-efbe04b1f63c Netherlands | |
| 827c34ff-479a-4864-9411-9b7485068d3b Spain | |
| 529713d3-e7e2-46e2-ad21-1ee6884c5827 Netherlands | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT1BE3125AFF000XXX |
| E-Number (Finland) | 3640496 |
| E-Number (Norway) | 4309609 |
| EAN | 8015644007157 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 76.2 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.137 kg |
| Package Level 1 EAN | 8015644007157 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0008 |
| Technical | |
| Connecting Capacity Main Circuit | Busbar 45.5 ... 80 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3P |
| Opening Time | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 10.7 W |
| Rated Current (In) | 125 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 1250 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 25 kA |
| (230 V AC) 25 kA | |
| (240 V AC) 25 kA | |
| (380 V AC) 18 kA | |
| (415 V AC) 18 kA | |
| (440 V AC) 11.25 kA | |
| (500 V AC) 8 kA | |
| (525 V AC) 6 kA | |
| (690 V AC) 3 kA | |
| (250 V DC) 2 Poles in Series 18 kA | |
| (500 V DC) 3 Poles in Series 18 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 25 kA |
| (230 V AC) 25 kA | |
| (240 V AC) 25 kA | |
| (380 V AC) 18 kA | |
| (415 V AC) 18 kA | |
| (440 V AC) 15 kA | |
| (500 V AC) 8 kA | |
| (525 V AC) 6 kA | |
| (690 V AC) 3 kA | |
| (250 V DC) 2 Poles in Series 18 kA | |
| (500 V DC) 3 Poles in Series 18 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMD |
| Release Type | TM |
| Setting Range | 87.5...125 A |
| Short-Circuit Performance Level | B |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| GL Certificate | 1SDL000163R0103 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000719R0100 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |