View larger
1SDA066807R1 ABB XT1B 160 TMD 100-1000 3p F F
1SDA066807R1
066807
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
XT1
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
ABB 1SDA066807R1 XT1B 160 is a 3-pole thermal-magnetic circuit breaker built to protect electrical circuits from overloads and short circuits. Molded case breakers are staple components in industrial control panels, ensuring safe distribution of power across various installations.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2347
- Environmental Product Declaration - EPD: 9AKK108468A1890
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 55.9 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 87da4ae5-d281-4cf7-89ae-08ea1f34c520 Italy
- Simplified SCIP: e1a75a7e-0f06-4343-b305-b0bb07d627d7 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT1BE3100AFF000XXX
- E-Number (Finland): 3640495
- E-Number (Norway): 4309608
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2347 |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 87da4ae5-d281-4cf7-89ae-08ea1f34c520 Italy |
| Simplified SCIP | e1a75a7e-0f06-4343-b305-b0bb07d627d7 Germany |
| 9136ee1a-0225-4485-8008-9b9b4f898003 France | |
| baa691e3-fb96-4aa9-9079-885f0ce9ffc7 Netherlands | |
| 19009d20-fe0a-406e-a6c7-754e2ce79a04 Spain | |
| 0d017bbc-bd89-4cba-9c40-ce382b69c941 Netherlands | |
| 1ac23e01-8938-4cfa-9554-5dc725569cd9 Estonia | |
| 3caf7a98-6d33-4e3d-9e3c-3696071c018c Greece | |
| b4a8fa85-471c-4024-9dfa-2b3b8002b1fd Portugal | |
| 40ae467e-12cd-4ff4-9b7b-0b06c10682c8 Bulgaria | |
| 34e0ba7e-9ada-4036-a46c-78818d351a10 Sweden | |
| 7688f27b-0303-4931-a1b9-201ec758eed9 Poland | |
| 2973e92d-a825-4905-b178-8271043cd3fc Netherlands | |
| 88dd4d2a-48ef-40e5-a5a4-8777e0caf1ae Poland | |
| 28af0011-3352-4568-ae2e-5c6f712f69ce Norway | |
| 139a4e60-c144-4385-9f47-109d95a5e80f Finland | |
| fdaa062c-f086-4a1a-84ad-e07827068768 Netherlands | |
| b45b713c-aac6-486d-860d-62c7bd566c76 Germany | |
| 7cd9e27b-8379-4d1d-9c10-2494ae68a5e5 Denmark | |
| b5672789-5124-44cd-b9aa-10e3f35aba7a Germany | |
| 4b159a82-b08b-4bd6-9325-11ce5cdf5448 Croatia | |
| dde32885-1587-472c-b2dd-1326e5aad4e2 Czech Republic | |
| f4f530b5-c734-46f4-9e51-1699fa3f6f95 Poland | |
| 7684609b-1286-40fa-be35-8e161c571a09 Netherlands | |
| 53567a62-c858-4312-a586-9c3dff2aeb2a France | |
| 97a62aeb-f463-485d-802c-da5b271e1915 Sweden | |
| 706a0ec2-b9e6-48d8-a2e7-e213302d4bc2 Germany | |
| 6f865dc7-914e-4ee1-bd3b-f9f2de603622 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT1BE3100AFF000XXX |
| E-Number (Finland) | 3640495 |
| E-Number (Norway) | 4309608 |
| EAN | 8015644694487 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 76.2 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.134 kg |
| Package Level 1 EAN | 8015644694487 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0008 |
| Technical | |
| Connecting Capacity Main Circuit | Busbar 45.5 ... 80 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3P |
| Opening Time | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 7 W |
| Rated Current (In) | 100 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 1000 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 25 kA |
| (230 V AC) 25 kA | |
| (240 V AC) 25 kA | |
| (380 V AC) 18 kA | |
| (415 V AC) 18 kA | |
| (440 V AC) 11.25 kA | |
| (500 V AC) 8 kA | |
| (525 V AC) 6 kA | |
| (690 V AC) 3 kA | |
| (250 V DC) 2 Poles in Series 18 kA | |
| (500 V DC) 3 Poles in Series 18 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 25 kA |
| (230 V AC) 25 kA | |
| (240 V AC) 25 kA | |
| (380 V AC) 18 kA | |
| (415 V AC) 18 kA | |
| (440 V AC) 15 kA | |
| (500 V AC) 8 kA | |
| (525 V AC) 6 kA | |
| (690 V AC) 3 kA | |
| (250 V DC) 2 Poles in Series 18 kA | |
| (500 V DC) 3 Poles in Series 18 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMD |
| Release Type | TM |
| Setting Range | 70...100 A |
| Short-Circuit Performance Level | B |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| GL Certificate | 1SDL000163R0103 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000719R0100 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |