View larger
GJL1211911R8100
1211911
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Popular Downloads | |
| EPLAN Data | 9AAC205199_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 2CDC102046M6801 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 96.2 mm |
| Product Net Depth / Length | 46.7 mm |
| Product Net Height | 57.5 mm |
| Product Net Weight | 0.355 kg |
| Dimension Diagram | GJL1200447F0001 |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-4-1 | |
| IEC/EN 60947-5-1 | |
| UL 60947-1 | |
| UL 60947-4-1 | |
| IEC 60335-2-40 A2L | |
| Rated Operational Voltage | Auxiliary Circuit 690 V AC |
| Auxiliary Circuit 250 V DC | |
| Main Circuit 690 V AC | |
| Main Circuit 220 V DC | |
| Rated Frequency (f) | Control Circuit 400 Hz |
| Control Circuit 50 Hz | |
| Control Circuit 60 Hz | |
| Main Circuit 60 Hz | |
| Main Circuit 50 Hz | |
| Main Circuit DC | |
| Conventional Free-air Thermal Current (Ith) | Main Circuit 20 A |
| Rated Operational Current AC-1 (Ie) | (220 / 240 V) 40 °C 20 A |
| (220 / 240 V) 55 °C 16 A | |
| (380 / 440 V) 40 °C 20 A | |
| (380 / 440 V) 55 °C 16 A | |
| (690 V) 40 °C 6 A | |
| (690 V) 55 °C 6 A | |
| Rated Operational Current AC-3 (Ie) | (230 V) 55°C 9 A |
| (400 V) 55 °C 9 A | |
| (500 V) 55 °C 6.5 A | |
| (690 V) NO 55°C 3.5 A | |
| Rated Operational Current AC-15 (Ie) | (440 V AC) 3 A |
| (24 V) 4 A | |
| (120 V) 4 A | |
| (240 V) 4 A | |
| (500 V) 2 A | |
| (380 / 400 V) 3 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 2.5 A |
| (110 V) 0.7 A | |
| (220 / 240 V) 0.4 A | |
| Rated Operational Power AC-3 (Pe) | (230 V) Three Phase 2.2 kW |
| (400 V) Three Phase 4 kW | |
| (500 V) Three Phase 4 kW | |
| (690 V) Three Phase, NO 3 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A |
| Rated Insulation Voltage (Ui) | 690 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-15) 600 cycles per hour | |
| (AC-3) 600 cycles per hour | |
| (DC-1) 600 cycles per hour | |
| (DC-13) 600 cycles per hour | |
| (DC-3) 600 cycles per hour | |
| Mechanical Durability | Nr. Operations 10000000 cycle |
| Minimum Switching Capacity | Auxiliary Circuit 17 V |
| Auxiliary Circuit 5 mA | |
| Coil Operating Limits | (acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| (acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) | |
| Rated Control Circuit Voltage (Uc) | 220 ... 240 V AC |
| Coil Consumption | Average Holding Value 50 Hz 3.5 V·A |
| Average Pull-in Value 50 Hz 3.5 V·A | |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1 W |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Rigid 1/2x 1 ... 4 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Rigid 1/2x 1 ... 4 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Rigid 1/2x 1 ... 4 mm² | |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Main Circuit 9 mm | |
| Degree of Protection | Auxiliary Circuit Terminals IP20 |
| Control Circuit Terminals IP20 | |
| Main Circuit Terminals IP20 | |
| Recommended Screw Driver | M3 |
| Pozidriv 1 | |
| Tightening Torque | Control Circuit 0.8 ... 1.1 N·m |
| Main Circuit 0.8 ... 1.1 N·m | |
| Terminal Type | Screw Terminals |
| Product Name | Mini Reversing Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| General Use Rating UL/CSA | (300 V AC) 12 A |
| Horsepower Rating UL/CSA | (115 V AC) Single Phase 0.25 Hp |
| (200 V AC) Three Phase 1 Hp | |
| (220 ... 240 V AC) Three Phase 2 Hp | |
| (230 V AC) Single Phase 0.5 Hp | |
| (440 ... 480 V AC) Three Phase 3 Hp | |
| (550 ... 600 V AC) Three Phase 1 Hp | |
| Connecting Capacity Main Circuit UL/CSA | Stranded 1/2x 22-10 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA | Stranded 1/2x 22-10 AWG |
| Contact Rating UL/CSA | A600 |
| Tightening Torque UL/CSA | Auxiliary Circuit 7 in·lb |
| Control Circuit 7 in·lb | |
| Main Circuit 7 in·lb | |
| Full Load Amps Motor Use | (115 V AC) Single Phase 5.8 A |
| (200 V AC) Three Phase 4.8 A | |
| (220 ... 240 V AC) Three Phase 6.8 A | |
| (230 V AC) Single Phase 4.9 A | |
| (440 ... 480 V AC) Three Phase 4.8 A | |
| (550 ... 600 V AC) Three Phase 1.7 A | |
| Environmental | |
| Ambient Air Temperature | Operation -20 ... +55 °C |
| Storage -40 ... +80 °C | |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g |
| Resistance to Vibrations | 5g 5 ... 150 Hz |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions | 1SBC100156C0269 |
| Environmental Product Declaration - EPD | 1SAC200410H0001 |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SAA938000-4601 |
| CB Certificate | 1SAA938000-2002 |
| CQC Certificate | CQC2003010304064033 |
| Declaration of Conformity - CCC | 2020980304001854 |
| Declaration of Conformity - CE | 1SAD101100-3101 |
| Declaration of Conformity - UKCA | 1SAD201100-3101 |
| DNV GL Certificate | 1SAA938000-0306 |
| EAC Certificate | 1SAA920000-2702 |
| KC Certificate | 1SAA938000-1501 |
| RMRS Certificate | 1SAA938000-0704 |
| UL Certificate | E191658-19881208 |
| Container Information | |
| Package Level 1 Units | box 5 piece |
| Package Level 1 Width | 115 mm |
| Package Level 1 Depth / Length | 280 mm |
| Package Level 1 Height | 54 mm |
| Package Level 1 Gross Weight | 1.845 kg |
| Package Level 1 EAN | 4013614414237 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000010 - Combination of contactors |
| ETIM 8 | EC000010 - Combination of contactors |
| ETIM 9 | EC000010 - Combination of contactors |
| eClass | V11.0 : 27371009 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4761 >> Magnet contactor, AC-switching |