View larger
1SFL431024R8400 ABB UA95-30-00RA 110V 50Hz Contactor
1SFL431024R8400
431024
ABB
1 Pcs.
Automation > Capacitor contactor
"A" SECRLP
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A high-capacity ABB 1SFL431024R8400 contactor provides reliable electrical circuit isolation and switching for heavy industrial plant infrastructure. It safely manages heavy operational loads and seamlessly integrates into automated control architectures. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 1SBC100214C0202
- Instructions and Manuals: 5309660-60
- CAD Dimensional Drawing: 2CDC001079B0201
- Product Net Width: 90 mm
- Product Net Depth / Length: 155.6 mm
- Product Net Height: 170 mm
- Product Net Weight: 1.8 kg
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 0
- Number of Poles: 3P
- Rated Operational Voltage: Main Circuit 1000 V
- Rated Frequency (f): Main Circuit 50 Hz
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 5309660-60 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 90 mm |
| Product Net Depth / Length | 155.6 mm |
| Product Net Height | 170 mm |
| Product Net Weight | 1.8 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 145 A |
| (690 V) 55 °C 135 A | |
| (690 V) 60 °C 135 A | |
| (690 V) 70 °C 115 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 96 A |
| (440 V) 55 °C 93 A | |
| (500 V) 55 °C 80 A | |
| (690 V) 55 °C 65 A | |
| (1000 V) 55 °C 30 A | |
| (380 / 400 V) 55 °C 96 A | |
| (220 / 230 / 240 V) 55 °C 96 A | |
| Rated Operational Power AC-3 (Pe) | (380 / 400 V) 45 kW |
| Rated Operational Power AC-6b (Pe) | (230 / 240 V) 40 °C, 50 / 60 Hz 40 kvar |
| (230 / 240 V) 55 °C, 50 / 60 Hz 35 kvar | |
| (230 / 240 V) 70 °C, 50 / 60 Hz 30 kvar | |
| (400 / 415 V) 40 °C, 50 / 60 Hz 70 kvar | |
| (400 / 415 V) 70 °C, 50 / 60 Hz 53 kvar | |
| (400 / 415 V) 55 °C, 50 / 60 Hz 60 kvar | |
| (440 V) 40 °C, 50 / 60 Hz 75 kvar | |
| (440 V) 55 °C, 50 / 60 Hz 65 kvar | |
| (440 V) 70 °C, 50 / 60 Hz 58 kvar | |
| (500 / 550 V), 40 °C, 50 / 60 Hz 85 kvar | |
| (500 / 550 V) 55 °C, 50 / 60 Hz 75 kvar | |
| (500 / 550 V) 70 °C, 50 / 60 Hz 70 kvar | |
| (690 V) 40 °C, 50 / 60 Hz 120 kvar | |
| (690 V) 55 °C, 50 / 60 Hz 105 kvar | |
| (690 V) 70 °C, 50 / 60 Hz 85 kvar | |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-2 / AC-4) 150 cycles per hour | |
| (AC-3) 300 cycles per hour | |
| Mechanical Durability | 10 million |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 110 V |
| 60 Hz 110 ... 120 V | |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 7.5 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 15 ms |
| Between Coil Energization and NO Contact Closing 10 ... 25 ms | |
| Connecting Capacity Main Circuit | Bar 30 mm² |
| Flexible with Cable End 2 x 6 ... 35 mm² | |
| Rigid 1 x 10 ... 95 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible 2x0.75 ... 2.5 mm² | |
| Solid 1 x 1 ... 4 mm² | |
| Stranded 2 x 1 .... 4 mm² | |
| Connecting Capacity | Bar 30 mm² |
| Flexible with Cable End 2 x 6 ... 35 mm² | |
| Rigid 1 x 10 ... 95 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Connecting Terminals (delivered in open position) Main Poles | M8 hexagon socket screw with single connector |
| Tightening Torque | Main Circuit 8 N·m |
| Terminal Type | Cable Clamp |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | |
| Close to Contactor for Storage -60 ... +80 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| Certificates and Declarations | |
| CB Certificate | CB_CN64637 |
| Declaration of Conformity - CE | 9AKK108471A1807 |
| Declaration of Conformity - UKCA | 2CMT2020-006118 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 170 mm |
| Package Level 1 Depth / Length | 140 mm |
| Package Level 1 Height | 170 mm |
| Package Level 1 Gross Weight | 2 kg |
| Package Level 1 EAN | 7320500260517 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC001079 - Capacitor contactor |
| ETIM 8 | EC001079 - Capacitor contactor |
| ETIM 9 | EC001079 - Capacitor contactor |
| eClass | V11.0 : 27371006 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4756 >> Capacitor magnet contactor |