View larger
1SBL351022R8011
351022
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | FPTC407700P0003 |
| Dimensions | |
| Product Net Width | 82 mm |
| Product Net Depth / Length | 108 mm |
| Product Net Height | 110 mm |
| Product Net Weight | 1.2 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Main Circuit 690 V | |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Control Circuit 50 / 60 Hz | |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
| (690 V) 2 A | |
| (24 / 127 V) 6 A | |
| (220 / 240 V) 4 A | |
| (380 / 400 V) 3 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
| (48 V) 2.8 A / 134 W | |
| (72 V) 1 A / 72 W | |
| (110 V) 0.55 A / 60 W | |
| (125 V) 0.55 A / 69 W | |
| (220 V) 0.30 A / 66 W | |
| (250 V) 0.3 / 75 W | |
| Rated Operational Power AC-6b (Pe) | (230 / 240 V) 40 °C, 50 / 60 Hz 20 kvar |
| (230 / 240 V) 55 °C, 50 / 60 Hz 20 kvar | |
| (230 / 240 V) 70 °C, 50 / 60 Hz 19 kvar | |
| (400 / 415 V) 40 °C, 50 / 60 Hz 33 kvar | |
| (400 / 415 V) 70 °C, 50 / 60 Hz 32 kvar | |
| (400 / 415 V) 55 °C, 50 / 60 Hz 33 kvar | |
| (440 V) 40 °C, 50 / 60 Hz 36 kvar | |
| (440 V) 55 °C, 50 / 60 Hz 36 kvar | |
| (440 V) 70 °C, 50 / 60 Hz 35 kvar | |
| (500 / 550 V), 40 °C, 50 / 60 Hz 40 kvar | |
| (500 / 550 V) 55 °C, 50 / 60 Hz 40 kvar | |
| (500 / 550 V) 70 °C, 50 / 60 Hz 40 kvar | |
| (690 V) 40 °C, 50 / 60 Hz 55 kvar | |
| (690 V) 55 °C, 50 / 60 Hz 55 kvar | |
| (690 V) 70 °C, 50 / 60 Hz 52 kvar | |
| Short-Circuit Protective Devices | Auxiliary Circuit - gG Type Fuses 10 A |
| gG Type Fuses 1.5 ... 1.8 A | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A |
| for 1 s 100 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V |
| acc. to IEC 60947-5-1 690 V | |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Minimum Switching Capacity | 17 / 5 VLT4K |
| Rated Control Circuit Voltage (Uc) | 50 Hz 220 ... 230 V |
| 60 Hz 230 ... 240 V | |
| Coil Consumption | Average Holding Value 50 / 60 Hz 18 V·A |
| Average Pull-in Value 50 Hz 180 V·A | |
| Average Pull-in Value 60 Hz 180 V·A | |
| Holding at Max. Rated Control Circuit Voltage 50 Hz 18 V·A | |
| Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 W | |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 18 V·A | |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 W | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 0.1 W |
| at 6 A per Pole 0.1 W | |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 14 ms |
| Between Coil De-energization and NO Contact Opening 4 ... 11 ms | |
| Between Coil Energization and NO Contact Closing 8 ... 27 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Cable End 6 ... 16 mm² |
| Rigid Cable 6 ... 25 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Cable End 0.75 ... 2.5 mm² |
| Rigid Cable 1 ... 4 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Connecting Terminals (delivered in open position) Main Poles | M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Environmental | |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C |
| Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C | |
| Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C | |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | bc5ed496-8082-4dcf-abb4-36c68158e5de Bulgaria |
| Simplified SCIP | 0b642710-ae18-4d31-8c6a-97992a497eb0 Sweden |
| 385711d6-5c3b-482e-be22-572981bdf705 Hungary | |
| 3f393742-9c63-4ff6-ae03-0e3450459041 Norway | |
| 4fa9688f-8513-44be-928e-ba988012f2d8 Denmark | |
| 55051b4f-8802-4d3d-9761-42a53f5ad246 Portugal | |
| 7ce8c498-b0da-4480-b37e-da05e8c9bb7b France | |
| 9202ec74-578f-4700-a90a-7342ce445dec Belgium | |
| a32fa436-8ab6-482a-8be7-e82b575e678a Italy | |
| b1a8c698-cca9-4e83-8f7c-cba7553803ee Poland | |
| be70af5a-78ae-4e43-8ca8-ab7c2c29cf12 Croatia | |
| bea9c246-437e-4ec0-be49-afbe482e1937 Germany | |
| bfdb69ef-b2dd-414b-946d-53d7c3ac3d75 Spain | |
| e24fc848-af32-4390-8f2e-4b54e65249b3 Greece | |
| ece71d42-2a48-42a2-a5d1-6a7fce18a6ff Finland | |
| f51f412b-f50f-4bc1-be39-0ef8bbe0f74f Estonia | |
| faa92405-e6d3-4896-83de-e5906b4cf85a Czech Republic | |
| fc90b192-4004-4127-92f8-bd0683c56a14 Netherlands | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| Certificates and Declarations | |
| CB Certificate | CB_FR2880_60002378 |
| CCC Certificate | CCC_2003010304060093 |
| CCC_2008010304290409 | |
| CQC Certificate | CQC2018010304128276 |
| CQC2008010304290409 | |
| Declaration of Conformity - CCC | 2020980304001623 |
| 2020980304001215 | |
| Declaration of Conformity - CE | 1SBD250805U1000 |
| Declaration of Conformity - UKCA | 1SBD250822U1000 |
| GOST Certificate | GOST_POCCFRME77B07175 |
| UL Certificate | UL-US-L312527-1101-21215991-6 |
| UL-CA-2139468-4 | |
| UL Listing Card | UL_E312527 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 140 mm |
| Package Level 1 Depth / Length | 146 mm |
| Package Level 1 Height | 96 mm |
| Package Level 1 Gross Weight | 1.2 kg |
| Package Level 1 EAN | 3471522085801 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC001079 - Capacitor contactor |
| ETIM 8 | EC001079 - Capacitor contactor |
| ETIM 9 | EC001079 - Capacitor contactor |
| eClass | V11.0 : 27371006 |
| UNSPSC | 39121529 |
| E-Number (Finland) | 3709174 |