View larger
1SBL281022R3610 ABB UA30-30-10 190V 50Hz / 220V 60Hz Contactor
1SBL281022R3610
281022
ABB
1 Pcs.
Automation > Capacitor contactor
"A" FRCTLP
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB UA30-30-10 190V 50Hz / 220V 60Hz Contactor is an electromechanical switching device utilized for frequent opening and closing of electrical power circuits in industrial environments. Contactors typically manage heavy motor loads, lighting banks, or heating elements safely through remote control signals. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 1SBC101140C0203
- Instructions and Manuals: FPTC407722P0001
- CAD Dimensional Drawing: 2CDC001079B0201
- Product Net Width: 54 mm
- Product Net Depth / Length: 108.3 mm
- Product Net Height: 90 mm
- Product Net Weight: 0.71 kg
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 0
- Number of Poles: 3P
- Standards: IEC/EN 60947-1, IEC/EN 60947-4-1
- Rated Operational Voltage: Auxiliary Circuit 690 V
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC101140C0203 |
| Instructions and Manuals | FPTC407722P0001 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 54 mm |
| Product Net Depth / Length | 108.3 mm |
| Product Net Height | 90 mm |
| Product Net Weight | 0.71 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Main Circuit 690 V | |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Control Circuit 50 / 60 Hz | |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
| (690 V) 2 A | |
| (24 / 127 V) 6 A | |
| (220 / 240 V) 4 A | |
| (380 / 400 V) 3 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
| (48 V) 2.8 A / 134 W | |
| (72 V) 2 / 144 W | |
| (110 V) 1.1 A / 121 W | |
| (125 V) 1.1 / 138 W | |
| (220 V) 0.55 A / 121 W | |
| (250 V) 0.55 / 138 W | |
| Rated Operational Power AC-6b (Pe) | (230 / 240 V) 40 °C, 50 / 60 Hz 16 kvar |
| (230 / 240 V) 55 °C, 50 / 60 Hz 16 kvar | |
| (230 / 240 V) 70 °C, 50 / 60 Hz 11 kvar | |
| (400 / 415 V) 40 °C, 50 / 60 Hz 27.5 kvar | |
| (400 / 415 V) 70 °C, 50 / 60 Hz 19 kvar | |
| (400 / 415 V) 55 °C, 50 / 60 Hz 27.5 kvar | |
| (440 V) 40 °C, 50 / 60 Hz 30 kvar | |
| (440 V) 55 °C, 50 / 60 Hz 30 kvar | |
| (440 V) 70 °C, 50 / 60 Hz 20 kvar | |
| (500 / 550 V), 40 °C, 50 / 60 Hz 34 kvar | |
| (500 / 550 V) 55 °C, 50 / 60 Hz 34 kvar | |
| (500 / 550 V) 70 °C, 50 / 60 Hz 23.5 kvar | |
| (690 V) 40 °C, 50 / 60 Hz 45 kvar | |
| (690 V) 55 °C, 50 / 60 Hz 45 kvar | |
| (690 V) 70 °C, 50 / 60 Hz 32 kvar | |
| Short-Circuit Protective Devices | Auxiliary Circuit - gG Type Fuses 10 A |
| gG Type Fuses 1.5 ... 1.8 A | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A |
| for 1 s 100 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V |
| acc. to IEC 60947-5-1 690 V | |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Mechanical Durability | 10 million |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Minimum Switching Capacity | 17 / 5 VLT4K |
| Rated Control Circuit Voltage (Uc) | 50 Hz 190 V |
| 60 Hz 220 V | |
| Coil Consumption | Average Holding Value 50 Hz 12 V·A |
| Average Holding Value 60 Hz 12 V·A | |
| Average Pull-in Value 50 Hz 120 V·A | |
| Average Pull-in Value 60 Hz 140 V·A | |
| Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | |
| Holding at Max. Rated Control Circuit Voltage 50 Hz 3 W | |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 3 W | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 120 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 140 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 0.1 W |
| at 6 A per Pole 0.1 W | |
| Operate Time | Between Coil De-energization and NO Contact Opening 4 ... 11 ms |
| Between Coil Energization and NO Contact Closing 8 ... 21 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M4 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Cable End 2.5 ... 10 mm² |
| Rigid Cable 2.5 ... 16 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Cable End 0.75 ... 2.5 mm² |
| Rigid Cable 1 ... 4 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 | |
| Connecting Terminals (delivered in open position) Main Poles | M 5 (+,-) pozidriv 2 screw with 2x (5.6x6.5 mm) connector |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Environmental | |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C |
| Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C | |
| Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C | |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 5c96122f-54a0-43cc-aba9-ce82f2807570 Bulgaria |
| Simplified SCIP | 08772048-c033-4b88-92c0-5d2c69e41d8e Poland |
| 1473fd6c-0908-4a04-9493-62174099859c Hungary | |
| 17763f26-0308-4d62-adbe-410168d1a737 Greece | |
| 37961ff4-4a9b-4ea4-8f0c-2e544705a091 Germany | |
| 4bec49a5-f4f4-40ce-84cf-9ef6cee28464 Norway | |
| 50c48f78-a808-4d20-9ee2-5561de350fe3 Croatia | |
| 53e6fd4c-5a6e-46ce-8693-54817fe6fd02 Denmark | |
| 5e60121f-8b30-4cd0-82db-726711bf7dc5 Belgium | |
| 666d1b4f-72f0-48a3-b601-9c5aa4fb36b0 Netherlands | |
| 7a564175-07b0-4d83-8e90-52f56bd49127 Portugal | |
| 7cdca0c4-bac8-4202-b0d3-b30a900c8385 Italy | |
| 8b746a08-a48c-4347-a75f-5d0527133f4b Estonia | |
| acce3009-90e6-4e25-9baf-ffb983c948e2 Czech Republic | |
| b353b509-f7d9-499c-8a81-9f69c5bd78c4 Sweden | |
| c7b21dfb-96e8-4947-8d01-79048b70d6c8 Spain | |
| e063390c-ec2c-4bc0-8034-1d4f7aad552c Finland | |
| eea2325c-dd3c-420e-9554-729f28bbc43f France | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| Certificates and Declarations | |
| CB Certificate | CB_CN64164-A1_1 |
| CCC Certificate | CCC_2007010309256050 |
| CQC Certificate | CQC2003010304060095 |
| CQC2007010309256050 | |
| Declaration of Conformity - CCC | 2020980304001610 |
| 2020980304001216 | |
| Declaration of Conformity - CE | 1SBD250805U1000 |
| Declaration of Conformity - UKCA | 1SBD250822U1000 |
| GOST Certificate | GOST_POCCFRME77B07175 |
| UL Certificate | UL-US-L312527-4104-71017991-2 |
| UL-CA-L312527-4104-71017991-2 | |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 101 mm |
| Package Level 1 Depth / Length | 115 mm |
| Package Level 1 Height | 61 mm |
| Package Level 1 Gross Weight | 0.71 kg |
| Package Level 1 EAN | 3471522074362 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC001079 - Capacitor contactor |
| ETIM 8 | EC001079 - Capacitor contactor |
| ETIM 9 | EC001079 - Capacitor contactor |
| eClass | V11.0 : 27371006 |
| UNSPSC | 39121529 |