View larger
1SBL281022R8910 ABB UA30-30-10 110-115V 50Hz / 115-127V 60Hz Contactor
1SBL281022R8910
281022
ABB
1 Pcs.
Automation > Capacitor contactor
"A" FRCTLP
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB UA30-30-10 110-115V 50Hz / 115-127V 60Hz Contactor serves as an electromechanical actuator for opening and closing main electrical pathways in industrial control panels. These devices are standard across factory automation lines, providing remote switching capabilities for distribution networks, motors, and lighting circuits. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 1SBC101140C0203
- Instructions and Manuals: FPTC407722P0001
- CAD Dimensional Drawing: 2CDC001079B0201
- Product Net Width: 54 mm
- Product Net Depth / Length: 108.3 mm
- Product Net Height: 90 mm
- Product Net Weight: 0.71 kg
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 0
- Number of Poles: 3P
- Standards: IEC/EN 60947-1, IEC/EN 60947-4-1
- Rated Operational Voltage: Auxiliary Circuit 690 V
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC101140C0203 |
| Instructions and Manuals | FPTC407722P0001 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 54 mm |
| Product Net Depth / Length | 108.3 mm |
| Product Net Height | 90 mm |
| Product Net Weight | 0.71 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Main Circuit 690 V | |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Control Circuit 50 / 60 Hz | |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
| (690 V) 2 A | |
| (24 / 127 V) 6 A | |
| (220 / 240 V) 4 A | |
| (380 / 400 V) 3 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
| (48 V) 2.8 A / 134 W | |
| (72 V) 2 / 144 W | |
| (110 V) 1.1 A / 121 W | |
| (125 V) 1.1 / 138 W | |
| (220 V) 0.55 A / 121 W | |
| (250 V) 0.55 / 138 W | |
| Rated Operational Power AC-6b (Pe) | (230 / 240 V) 40 °C, 50 / 60 Hz 16 kvar |
| (230 / 240 V) 55 °C, 50 / 60 Hz 16 kvar | |
| (230 / 240 V) 70 °C, 50 / 60 Hz 11 kvar | |
| (400 / 415 V) 40 °C, 50 / 60 Hz 27.5 kvar | |
| (400 / 415 V) 70 °C, 50 / 60 Hz 19 kvar | |
| (400 / 415 V) 55 °C, 50 / 60 Hz 27.5 kvar | |
| (440 V) 40 °C, 50 / 60 Hz 30 kvar | |
| (440 V) 55 °C, 50 / 60 Hz 30 kvar | |
| (440 V) 70 °C, 50 / 60 Hz 20 kvar | |
| (500 / 550 V), 40 °C, 50 / 60 Hz 34 kvar | |
| (500 / 550 V) 55 °C, 50 / 60 Hz 34 kvar | |
| (500 / 550 V) 70 °C, 50 / 60 Hz 23.5 kvar | |
| (690 V) 40 °C, 50 / 60 Hz 45 kvar | |
| (690 V) 55 °C, 50 / 60 Hz 45 kvar | |
| (690 V) 70 °C, 50 / 60 Hz 32 kvar | |
| Short-Circuit Protective Devices | Auxiliary Circuit - gG Type Fuses 10 A |
| gG Type Fuses 1.5 ... 1.8 A | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A |
| for 1 s 100 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V |
| acc. to IEC 60947-5-1 690 V | |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Minimum Switching Capacity | 17 / 5 VLT4K |
| Rated Control Circuit Voltage (Uc) | 50 Hz 110 ... 115 V |
| 60 Hz 115 ... 127 V | |
| Coil Consumption | Average Holding Value 50 / 60 Hz 12 V·A |
| Average Pull-in Value 50 Hz 125 V·A | |
| Average Pull-in Value 60 Hz 120 V·A | |
| Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | |
| Holding at Max. Rated Control Circuit Voltage 50 Hz 3 W | |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 3 W | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 120 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 140 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 0.1 W |
| at 6 A per Pole 0.1 W | |
| Operate Time | Between Coil De-energization and NO Contact Opening 4 ... 11 ms |
| Between Coil Energization and NO Contact Closing 8 ... 21 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M4 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Cable End 2.5 ... 10 mm² |
| Rigid Cable 2.5 ... 16 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Cable End 0.75 ... 2.5 mm² |
| Rigid Cable 1 ... 4 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 | |
| Connecting Terminals (delivered in open position) Main Poles | M 5 (+,-) pozidriv 2 screw with 2x (5.6x6.5 mm) connector |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Environmental | |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C |
| Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C | |
| Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C | |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 90ade173-0e89-467c-83b4-18fb7f807a1b Bulgaria |
| Simplified SCIP | 1ec98447-2205-407a-a08a-d66a32e643a9 Germany |
| 2cce1499-fa8e-4ee5-a296-7cb2882aa1d1 Finland | |
| 3ab8d4e0-f328-4766-b0a1-6a2e536730c5 Croatia | |
| 4c8aa39c-0795-4dc0-8569-94ffc709d2ca Spain | |
| 4e64b826-5074-42d7-b669-6107f95a4a46 France | |
| 5174acea-2bf0-4152-a6ee-653107650089 Estonia | |
| 5d4d1af0-62ff-4182-8419-9c65db4762ea Denmark | |
| 6bad98e2-c6cf-419d-a848-f5108dff3c52 Portugal | |
| 759dab04-31fb-44eb-b9c8-608632398a51 Hungary | |
| 7a2c2c6a-5e62-459f-80e7-74bd42500f69 Italy | |
| b2867a72-2427-4aac-8155-42cee79dd657 Sweden | |
| ca0856e0-878c-4c3c-9a7e-5ae0f104eac8 Czech Republic | |
| cf3a46a4-d846-47c4-a0ff-95e5f563a725 Poland | |
| d8d87117-428f-4d79-898b-2c85d927159b Norway | |
| dcd4b703-53eb-48c7-82b9-23eb6f1aecfb Greece | |
| e2106185-b5e6-4b4e-ac08-e4fdd0201362 Belgium | |
| e4c39b8e-12a4-4c3f-ba39-885ac71545e6 Netherlands | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| Certificates and Declarations | |
| CB Certificate | CB_CN64164-A1_1 |
| CQC Certificate | CQC2003010304060095 |
| CQC2007010309256050 | |
| Declaration of Conformity - CCC | 2020980304001610 |
| 2020980304001216 | |
| Declaration of Conformity - CE | 1SBD250805U1000 |
| Declaration of Conformity - UKCA | 1SBD250822U1000 |
| GOST Certificate | GOST_POCCFRME77B07175 |
| UL Certificate | UL-US-L312527-4104-71017991-2 |
| UL-CA-L312527-4104-71017991-2 | |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 101 mm |
| Package Level 1 Depth / Length | 115 mm |
| Package Level 1 Height | 61 mm |
| Package Level 1 Gross Weight | 0.71 kg |
| Package Level 1 EAN | 3471522074898 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC001079 - Capacitor contactor |
| ETIM 8 | EC001079 - Capacitor contactor |
| ETIM 9 | EC001079 - Capacitor contactor |
| eClass | V11.0 : 27371006 |
| UNSPSC | 39121529 |