View larger
1SBL241024R8410
241024
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 1SBC101002M5501 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 54 mm |
| Product Net Depth / Length | 126.3 mm |
| Product Net Height | 120 mm |
| Product Net Weight | 0.71 kg |
| Dimension Diagram | FPTE307846 |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Main Circuit 690 V | |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Control Circuit 50 / 60 Hz | |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
| (690 V) 2 A | |
| (24 / 127 V) 6 A | |
| (220 / 240 V) 4 A | |
| (380 / 400 V) 3 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
| (48 V) 2.8 A / 134 W | |
| (72 V) 2 / 144 W | |
| (110 V) 1.1 A / 121 W | |
| (125 V) 1.1 / 138 W | |
| (220 V) 0.55 A / 121 W | |
| (250 V) 0.55 / 138 W | |
| Rated Operational Power AC-6b (Pe) | (230 / 240 V) 40 °C, 50 / 60 Hz 12.5 kvar |
| (230 / 240 V) 55 °C, 50 / 60 Hz 11.5 kvar | |
| (230 / 240 V) 70 °C, 50 / 60 Hz 9 kvar | |
| (400 / 415 V) 40 °C, 50 / 60 Hz 22 kvar | |
| (400 / 415 V) 70 °C, 50 / 60 Hz 15.5 kvar | |
| (400 / 415 V) 55 °C, 50 / 60 Hz 20 kvar | |
| (440 V) 40 °C, 50 / 60 Hz 24 kvar | |
| (440 V) 55 °C, 50 / 60 Hz 20 kvar | |
| (440 V) 70 °C, 50 / 60 Hz 17 kvar | |
| (500 / 550 V), 40 °C, 50 / 60 Hz 30 kvar | |
| (500 / 550 V) 55 °C, 50 / 60 Hz 25 kvar | |
| (500 / 550 V) 70 °C, 50 / 60 Hz 20 kvar | |
| (690 V) 40 °C, 50 / 60 Hz 35 kvar | |
| (690 V) 55 °C, 50 / 60 Hz 31 kvar | |
| (690 V) 70 °C, 50 / 60 Hz 26 kvar | |
| Short-Circuit Protective Devices | Auxiliary Circuit - gG Type Fuses 10 A |
| gG Type Fuses 125 A | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A |
| for 1 s 100 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V |
| acc. to IEC 60947-5-1 690 V | |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Electrical Durability | Ue =< 440 V 250000 cycle |
| Ue = 500 ... 690 V 100000 cycle | |
| Maximum Electrical Switching Frequency | 240 cycles per hour |
| Minimum Switching Capacity | 17 / 5 VLT4K |
| Rated Control Circuit Voltage (Uc) | 50 Hz 110 V |
| 60 Hz 110 ... 120 V | |
| Coil Consumption | Average Holding Value 50 / 60 Hz 12 V·A |
| Average Holding Value 50 Hz 12 V·A | |
| Average Holding Value 60 Hz 12 V·A | |
| Average Pull-in Value 50 Hz 120 V·A | |
| Average Pull-in Value 60 Hz 140 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 0.1 W |
| at 6 A per Pole 0.1 W | |
| Operate Time | Between Coil De-energization and NO Contact Opening 4 ... 11 ms |
| Between Coil Energization and NO Contact Closing 8 ... 21 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M4 Screws Placed Diagonally |
| Connecting Capacity Auxiliary Circuit | Flexible with Cable End 0.75 ... 2.5 mm² |
| Rigid Cable 1 ... 4 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 | |
| Connecting Terminals (delivered in open position) Main Poles | M 4 (+,-) pozidriv 2 screws with cable clamp |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Environmental | |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C |
| Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C | |
| Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C | |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Simplified SCIP | 0124fb76-6579-4f7a-95a6-69af4fa16456 Belgium |
| 01f86868-9bb8-4d2a-9402-08e2eaaaf1c7 Norway | |
| 2b91fa91-6185-4794-a923-0e8908376854 Croatia | |
| 48363386-4024-4f4e-a891-4d03a5f2c819 Poland | |
| 52551427-bfac-4bd1-9e0b-7bd6ad8fc301 France | |
| 58c16533-63fa-470b-b08a-0343bee7c30c Denmark | |
| 5dd0775e-2305-45dd-9652-e51c0a839d12 Germany | |
| 645d1903-aad6-44cc-9a27-827da8edfde4 Netherlands | |
| 70c9ff90-9154-43ff-ae7f-ad7557bbc319 Germany | |
| 7652cc87-6f81-4dac-8142-951759989b50 Greece | |
| 77c0c48c-8958-4f7d-a74d-e40a5f95cfa9 Belgium | |
| 7f741a33-e218-4355-b0c6-e6f762d0742f Estonia | |
| 8bca2648-7a2d-4e10-b67e-746f970b3b92 Poland | |
| 8c30f80d-21e6-4bb7-af50-f40e20e7fbe0 Sweden | |
| 97cc8182-cbd6-47f2-9cad-adee6581c2f2 Portugal | |
| ae10928f-bec9-4cce-9276-3d8d8b7b29bc Hungary | |
| b3c2a2c8-41c7-4ece-845b-501a3f054d89 Spain | |
| bb62e5ba-04ed-4398-80d4-6b17d56df564 Hungary | |
| c3668619-e8c9-4a1b-b4bd-42b7f49bbcbb Finland | |
| cdf6a719-7b85-4a5a-acf9-617a03aab6b5 Sweden | |
| f2801ced-daa0-4692-9281-b47dc304d4e8 Czech Republic | |
| f8ea0603-cf82-44d2-9e8e-db4e4339ed09 Italy | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| Certificates and Declarations | |
| CB Certificate | CB_FR3447_60016915-509739B |
| CCC Certificate | CCC_2004010304138316 |
| CQC Certificate | CQC2003010304060095 |
| CQC2008010304261926 | |
| CSA Certificate | CSA_1033838_LR056745 |
| Declaration of Conformity - CCC | 2020980304001610 |
| 2020980304001217 | |
| Declaration of Conformity - CE | 1SBD250805U1000 |
| Declaration of Conformity - UKCA | 1SBD250822U1000 |
| GOST Certificate | GOST_POCCFRME77B07175 |
| UL Certificate | UL-US-L312527-1103-61017991-2 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 135 mm |
| Package Level 1 Depth / Length | 155 mm |
| Package Level 1 Height | 63 mm |
| Package Level 1 Gross Weight | 0.71 kg |
| Package Level 1 EAN | 3471522301840 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC001079 - Capacitor contactor |
| ETIM 8 | EC001079 - Capacitor contactor |
| ETIM 9 | EC001079 - Capacitor contactor |
| eClass | V11.0 : 27371006 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4756 >> Capacitor magnet contactor |
| Feature Name | Feature Value |
|---|---|
| Rated control supply voltage AC 50 Hz (EF003978) | 110 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 110 V |
| Voltage type for actuating (EF008242) | AC |
| Number of auxiliary contacts as normally open contact (EF001376) | 1 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Number of normally open contacts as main contact (EF001374) | 3 |
| Number of normally closed contacts as main contact (EF001375) | 0 |
| Rated reactive power at 400 V, 50 Hz (EF007044) | 22 kvar |