ABB 1SBL241022R8010 1SBL241022R8010 ABB UA26-30-10 220-230V 50Hz / 230-240V 60Hz Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SBL241022R8010 ABB UA26-30-10 220-230V 50Hz / 230-240V 60Hz Contactor

1SBL241022R8010

241022

ABB

1 Pcs.

UA26-30-10 220-230V 50Hz / 230-240V 60Hz Contactor UA26-30-10 CONT. condens. 20kVAr 230V

Automation > Capacitor contactor
"A" FRCTLP

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information1SBC100214C0202
Instructions and ManualsFPTC407722P0001
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width54 mm
Product Net Depth / Length93.6 mm
Product Net Height90 mm
Product Net Weight0.6 kg
Technical
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC0
Number of Poles3P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1
Rated Operational VoltageAuxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 2 / 144 W
(110 V) 1.1 A / 121 W
(125 V) 1.1 / 138 W
(220 V) 0.55 A / 121 W
(250 V) 0.55 / 138 W
Rated Operational Power AC-6b (Pe)(230 / 240 V) 40 °C, 50 / 60 Hz 12 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 11 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 8.5 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 20 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 14.5 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 18.5 kvar
(440 V) 40 °C, 50 / 60 Hz 22 kvar
(440 V) 55 °C, 50 / 60 Hz 20 kvar
(440 V) 70 °C, 50 / 60 Hz 16 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 22 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 22 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 19.5 kvar
(690 V) 40 °C, 50 / 60 Hz 30 kvar
(690 V) 55 °C, 50 / 60 Hz 30 kvar
(690 V) 70 °C, 50 / 60 Hz 25 kvar
Short-Circuit Protective DevicesAuxiliary Circuit - gG Type Fuses 10 A
gG Type Fuses 1.5 ... 1.8 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Mechanical Durability10 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Minimum Switching Capacity17 / 5 VLT4K
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 12 V·A
Average Pull-in Value 50 Hz 120 V·A
Average Pull-in Value 60 Hz 120 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 3 W
Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 3 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 120 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 140 V·A
Power Lossat Rated Operating Conditions per Pole 0.1 W
at 6 A per Pole 0.1 W
Operate TimeBetween Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 8 ... 21 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Cable End 0.75 ... 4 mm²
Rigid Cable 1.5 ... 6 mm²
Connecting Capacity Auxiliary CircuitFlexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Connecting Terminals (delivered in open position) Main PolesM 4 (+,-) pozidriv 2 screws with cable clamp
Terminal TypeScrew Terminals
Product NameBlock Contactor
Environmental
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstandaccording to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Pollution Degree3
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Simplified SCIP0f19ed8f-bc2e-496d-b87c-8aed3a8b845f Sweden
0faf4dad-c008-423f-89bd-a99ff4738be1 Germany
1d739bcc-ca45-4c63-824b-1a80ffdcbef8 Sweden
222a442c-30cb-4485-a9a1-b3e0cf093725 Portugal
24a815d6-c019-497a-a6c7-2f61330b25dc Belgium
3596924d-404b-450b-84ae-33f68e7e1ded Finland
3c87dbec-0352-47b2-9722-6386c6c1b26b Italy
4131dfe3-2761-424a-8f22-5942100df843 France
473b03e7-0fd9-457f-bd66-99e7b0453393 Estonia
72e9cb8c-2964-4cf9-860d-329f107e2d73 Czech Republic
8f85fbee-e47c-4fb4-9c33-6d4297499e56 Hungary
add119f0-c807-4b76-b694-cf975e4f3836 Denmark
b50681f8-0b5f-42e4-babc-839c92a39ea3 Poland
b6c0a9af-182a-40b8-8f00-ee0e407062f3 Norway
c431f783-14c7-45b2-b006-354aa7a78520 Croatia
c5ac3a39-f354-4c50-acf4-afd8de9b77ed Poland
c80d9917-e711-4eb9-b577-6c5e08a9c02c Greece
c84c4b37-d826-45cc-853f-6da022b821ae Spain
d1dc89d9-2946-41d7-9b90-4e361c9ea7f4 Netherlands
e2a1efa6-27de-4939-b6b2-d8dce14f47a8 Germany
ff26beb6-f583-4548-892c-f5d93569291b Hungary
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
CB CertificateCB_CN64164-A1_1
CCC CertificateCCC_2003010304060095
CCC_2008010304261926
CQC CertificateCQC2003010304060095
CQC2008010304261926
CSA CertificateCSA_1033838_LR056745
Declaration of Conformity - CCC2020980304001610
2020980304001217
Declaration of Conformity - CE1SBD250805U1000
Declaration of Conformity - UKCA1SBD250822U1000
GOST CertificateGOST_POCCFRME77B07175
UL CertificateUL-US-L312527-1103-61017991-2
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width101 mm
Package Level 1 Depth / Length115 mm
Package Level 1 Height61 mm
Package Level 1 Gross Weight0.6 kg
Package Level 1 EAN3471522069801
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC001079 - Capacitor contactor
ETIM 8EC001079 - Capacitor contactor
ETIM 9EC001079 - Capacitor contactor
eClassV11.0 : 27371006
UNSPSC39121529
E-Number (Finland)3709172

ETIM for 1SBL241022R8010 Low-voltage industrial controls and switchgear (EC001079)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 220 V
Rated control supply voltage AC 60 Hz (EF003979) 230 V
Voltage type for actuating (EF008242) AC
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) 0
Type of electrical connection of main circuit (EF006819) Screw connection
Number of normally open contacts as main contact (EF001374) 3
Number of normally closed contacts as main contact (EF001375) 0
Rated reactive power at 400 V, 50 Hz (EF007044) 20 kvar

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.