View larger
1SAZ811201R1002 ABB TF65-33 Thermal Overload Relay
1SAZ811201R1002
811201
ABB
1 Pcs.
Automation > Thermal overload relay
Thermal Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for robust electrical protection, the Abb 1SAZ811201R1002 thermal overload relay prevents industrial motors from overheating by monitoring current levels and tripping the contactor during prolonged overloads. It is a critical safety component installed in commercial and industrial motor control panels worldwide.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 2CDC106069D0201
- Instructions and Manuals: 2CDC106051M6803
- Instructions and Manuals (Part 2): 1SAC200017M0002
- Ex Operating Instructions: 2CDC106085M6801
- Time-Current Characteristic Curve: 1SAZ800502F0002
- CAD Dimensional Drawing: 2CDC001079B0201
- Dimension Diagram: 1SAZ800401F0001
- Product Net Width: 54.9 mm
- Product Net Height: 101.4 mm
- Product Net Depth / Length: 106.9 mm
- Product Net Weight: 0.372 kg
- Setting Range: 25 ... 33 A
- Rated Operational Voltage: Auxiliary Circuit 600 V AC/DC
- Rated Operational Current (I e ): 33 A
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC106069D0201 |
| Instructions and Manuals | 2CDC106051M6803 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| Ex Operating Instructions | 2CDC106085M6801 |
| Time-Current Characteristic Curve | 1SAZ800502F0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimension Diagram | 1SAZ800401F0001 |
| Dimensions | |
| Product Net Width | 54.9 mm |
| Product Net Height | 101.4 mm |
| Product Net Depth / Length | 106.9 mm |
| Product Net Weight | 0.372 kg |
| Technical | |
| Setting Range | 25 ... 33 A |
| Rated Operational Voltage | Auxiliary Circuit 600 V AC/DC |
| Main Circuit 690 V AC | |
| Main Circuit 440 V DC | |
| Rated Operational Current (Ie) | 33 A |
| Rated Frequency (f) | Auxiliary Circuit 50 Hz |
| Auxiliary Circuit 60 Hz | |
| Auxiliary Circuit DC | |
| Main Circuit 50 Hz | |
| Main Circuit 60 Hz | |
| Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV |
| Main Circuit 8 kV | |
| Rated Insulation Voltage (Ui) | 690 V |
| Number of Poles | 3 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Protected Poles | 3 |
| Conventional Free-air Thermal Current (Ith) | Auxiliary Circuit NC 6 A |
| Auxiliary Circuit NO 4 A | |
| Rated Operational Current AC-15 (Ie) | (120 V) NC 3 A |
| (120 V) NO 0.5 A | |
| (240 V) NC 3 A | |
| (240 V) NO 0.5 A | |
| (400 V) NC 0.75 A | |
| (400 V) NO 0.5 A | |
| (500 V) NC 0.75 A | |
| (500 V) NO 0.5 A | |
| Rated Operational Current DC-13 (Ie) | (125 V) NC 0.55 A |
| (125 V) NO 0.55 A | |
| (24 V) NC 1.25 A | |
| (24 V) NO 1.25 A | |
| (250 V) NC 0.27 A | |
| (250 V) NO 0.27 A | |
| (500 V) NC 0.15 A | |
| (500 V) NO 0.15 A | |
| (60 V) NC 0.55 A | |
| (60 V) NO 0.55 A | |
| Degree of Protection | Housing IP20 |
| Main Circuit Terminals IP10 | |
| Pollution Degree | 3 |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
| Flexible 1/2x 0.75 ... 1 mm² | |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Rigid 1/2x 0.75 ... 4 mm² | |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 2.5 ... 10 mm² |
| Flexible with Ferrule 1x 2.5 ... 35 mm² | |
| Flexible with Insulated Ferrule 1x 2.5 ... 35 mm² | |
| Flexible with Insulated Ferrule 1/2x 2.5 ... 10 mm² | |
| Flexible 1/2x 2.5 ... 16 mm² | |
| Flexible 1x 2.5 ... 35 mm² | |
| Rigid 1/2x 2.5 ... 16 mm² | |
| Rigid 1x 2.5 ... 35 mm² | |
| Tightening Torque | Auxiliary Circuit 1 ... 1.2 N·m |
| Main Circuit 4.0 ... 4.5 N·m | |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Main Circuit 17 mm | |
| Recommended Screw Driver | Auxiliary Circuit Pozidriv 2 |
| Main Circuit Pozidriv 2 | |
| Mounting Position | 1 ... 6 |
| Power Loss | at Rated Operating Conditions per Pole 2.2 ... 3.8 W |
| Suitable For | AF40 |
| AF52 | |
| AF65 | |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-4-1 | |
| IEC/EN 60947-5-1 | |
| UL 60947-1 | |
| UL 60947-4-1 | |
| IEC 60335-2-40 A2L | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Contact Rating UL/CSA | (NC:) B600 |
| (NC:) Q600 | |
| (NO:) Q600 | |
| (NO:) D300 | |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1x 12-2 AWG |
| Flexible 2x 12-6 AWG | |
| Stranded 1x 12-2 AWG | |
| Stranded 2x 12-6 AWG | |
| Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-12 AWG |
| Stranded 1/2x 18-12 AWG | |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 ... 11 in·lb |
| Main Circuit 35 ... 40 in·lb | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... +70 °C |
| Operation Compensated -40 ... +70 °C | |
| Storage -50 ... +80 °C | |
| Ambient Air Temperature Compensation | Yes |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to Vibrations | 5g 3 ... 150 Hz |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Information | 2CMT2021-006277 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Circular Value | |
| End of Life Instructions | 1SAC200334H0001 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 1SAC200249H0001 |
| Environmental Information | 1SAC200058H0009 |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SAA941000-4601 |
| ABS Certificate | 1SAA941003-0101 |
| ATEX Certificate | 1SAA941005-3901 |
| BV Certificate | 1SAA941001-0203 |
| CB Certificate | 1SAA941015-2001 |
| CQC Certificate | CQC2014010309689432 |
| Declaration of Conformity - CCC | 2020980309000291 |
| Declaration of Conformity - CE | 1SAD101100-3503 |
| Declaration of Conformity - UKCA | 1SAD201100-3503 |
| DNV GL Certificate | 1SAA941004-0301 |
| EAC Certificate | 1SAA941002-2701 |
| IECEx Certificate | 1SAA941001-4001 |
| LR Certificate | 1SAA941003-0501 |
| RINA Certificate | RINA_ELE098115XG |
| RMRS Certificate | 1SAA941002-0701 |
| UL Certificate | E48139-20130329 |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 123 mm |
| Package Level 1 Height | 121 mm |
| Package Level 1 Depth / Length | 82 mm |
| Package Level 1 Gross Weight | 0.456 kg |
| Package Level 1 EAN | 4013614482922 |
| Package Level 2 Units | 12 piece |
| Package Level 2 Width | 280 mm |
| Package Level 2 Height | 210 mm |
| Package Level 2 Depth / Length | 395 mm |
| Package Level 2 Gross Weight | 5.858 kg |
| Package Level 2 EAN | 4013614485329 |
| Classifications | |
| Object Classification Code | F |
| ETIM 4 | EC000106 - Thermal overload relay |
| ETIM 5 | EC000106 - Thermal overload relay |
| ETIM 6 | EC000106 - Thermal overload relay |
| ETIM 7 | EC000106 - Thermal overload relay |
| ETIM 8 | EC000106 - Thermal overload relay |
| eClass | V11.0 : 27371501 |
| UNSPSC | 39122330 |
| IDEA Granular Category Code (IGCC) | 5366 >> Thermal overload relay |
| E-Number (Finland) | 3706584 |
| E-Number (Sweden) | 3210264 |