View larger
1SDA060280R1 ABB T6S 800 PR222DS/P-LSI In 800 3p F F
1SDA060280R1
060280
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
T6
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SDA060280R1 T6S 800 PR222DS/P-LSI In 800 3p F F is a molded case circuit breaker engineered to handle high-current distribution requirements and protect electrical equipment. Industrial installations depend on these breakers for precise overcurrent protection and fault isolation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 6391e39f-80d7-4062-8c75-1bfbee6239b5 Italy
- Simplified SCIP: 86c34824-4f93-456c-bfa6-8bf3864003bb Greece
- Environmental Information: 9AKK10103A1058
- E-Number (Finland): 3655439
- EAN: 8015644627423
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 210 mm
- Product Net Height: 268 mm
- Product Net Depth / Length: 103.5 mm
- Product Net Weight: 9.5 kg
More info
▲| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 6391e39f-80d7-4062-8c75-1bfbee6239b5 Italy |
| Simplified SCIP | 86c34824-4f93-456c-bfa6-8bf3864003bb Greece |
| 178c610f-0757-428c-b935-faf9f5ab2643 Hungary | |
| 94325897-6eb2-4fba-b63b-03bb952b4861 Netherlands | |
| f343ea3f-93a2-4064-b150-36b71bef904d Hungary | |
| cc609f4e-0508-494a-92c5-94f2c9333bbf Germany | |
| 7906c71b-aa8c-4ce7-a062-56f2ae07f6e5 Sweden | |
| 0548e11a-02f1-4201-b005-1311c9d3919a Bulgaria | |
| c8804ab9-5f8d-4c87-a85e-2da1ca8e8db9 Portugal | |
| 5b9975e8-cf07-4300-a7bc-e3864bf4a21d Poland | |
| c66da38d-26cb-4aa3-8aa9-257584c9fa7c France | |
| a7c612c6-d49a-4745-9536-c8e441059016 Germany | |
| f0d7d4c9-89b8-4997-a57a-fb9872b06372 Germany | |
| ab1c8719-7445-4d53-85e0-80f0b23a569c Denmark | |
| 8d41dfde-4b29-4fdb-b320-501a1f96c140 Poland | |
| ad665a62-8ac3-4000-93fe-2d94f9127abb Estonia | |
| c99da4e6-c816-49fb-b265-cd54247472b1 Croatia | |
| b5596edb-6125-4257-af89-2ec3b5657141 Germany | |
| 54581d54-bca5-4e11-ac81-b5e42d366422 Czech Republic | |
| 127f3979-b7ab-4435-bfd1-4330d5b1f107 Sweden | |
| 7ff02cc1-9ce4-43c7-b5d0-661396f7e621 France | |
| ce70dbfc-0cc4-487d-9761-4c339da450a2 Belgium | |
| 5b1909bc-0d1c-4b93-9f3d-bcf8690f3d17 Finland | |
| 17c0db84-5217-4fbb-82ad-0d654a99695d Germany | |
| f89f9052-feb8-4b7e-ab3f-04803e9c29b3 Poland | |
| c0698b96-e25b-46bb-a702-6be100058dad Norway | |
| 94769d8a-b4cf-4b86-b9f2-1feefd2387ed Spain | |
| 5b29d624-0103-4c17-8de1-b691ca717d40 Belgium | |
| Environmental | |
| Environmental Information | 9AKK10103A1058 |
| 9AKK108467A6707 | |
| Ordering | |
| E-Number (Finland) | 3655439 |
| EAN | 8015644627423 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 9.5 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 11 kg |
| Package Level 1 EAN | 8015644627423 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T6 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | at Rated Operating Conditions per Pole 32 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (690 V AC) 16.5 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 10 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (690 V AC) 22 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | PR222DS/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | T6 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210015D0201 |
| Declaration of Conformity - CE | 9AKK106713A5538 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH000511R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |