View larger
1SDA060283R1 ABB T6S 800 PR221DS-LS/I In 800 4p F F
1SDA060283R1
060283
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
T6
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The ABB T6S 800 PR221DS-LS/I In 800 4p F F functions as an industrial circuit breaker designed to provide dependable overcurrent protection in complex power grids. These devices are widely used in commercial switchboards and manufacturing facilities to safeguard electrical systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 93672a72-5bf0-48a7-80c0-afd7f2845497 China
- Simplified SCIP: 2825306c-67b2-47eb-a061-5bc952fbd8bf Germany
- Environmental Information: 9AKK10103A1058
- E-Number (Finland): 3655427
- EAN: 8015644627454
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 280 mm
- Product Net Height: 268 mm
- Product Net Depth / Length: 103.5 mm
- Product Net Weight: 12 kg
More info
▲| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 93672a72-5bf0-48a7-80c0-afd7f2845497 China |
| Simplified SCIP | 2825306c-67b2-47eb-a061-5bc952fbd8bf Germany |
| 486ce9b5-a46c-423d-b7c2-acc8d1321b5f Denmark | |
| 0fb2be62-8e52-4611-b747-cbbc79319d07 Greece | |
| f773946c-79f7-46ab-ac38-077985bdc5f4 Hungary | |
| fb4884f3-50a1-46fb-b5da-201719d16c37 Germany | |
| e5a776c9-732f-4af2-86a2-5c872655ea8e Norway | |
| c91c022d-8e0e-4562-8884-a77791e511f3 Germany | |
| d447634b-39af-45d4-a86e-9bdba8d7da41 France | |
| cca389ff-9ec4-4c36-a0bf-f646f5ae953e Poland | |
| a0410760-68cd-4640-b2c7-f527d470e24d Spain | |
| db4fdcb1-b571-4ea5-b636-19682e99ba74 Germany | |
| f20d8497-28d9-416d-a8c4-e82759d91ad7 Finland | |
| b1cc034f-40a1-4fc3-94a6-fcd2fb2860f8 Portugal | |
| 9ba226f6-d821-4039-8fa8-9567d3c4c755 Germany | |
| b14dbc96-3a24-4058-8aec-11bcc0e8559b Sweden | |
| 0b7f5bdc-e9c3-4d6f-969e-a46f7e3b9f64 France | |
| 04663a4e-96c6-4c8d-9282-afef8643ffee Netherlands | |
| 1bc1a55f-1abc-49bb-a56a-021d682d714d Poland | |
| 2d93a4f3-fda9-4722-aad7-59bab6be0822 Sweden | |
| a4791fc0-bc65-468a-923f-b408db76d6c8 Poland | |
| 857a531d-cbec-4584-965e-b01aa8bec45d Bulgaria | |
| 7b47158b-ad1d-4008-9757-edd28568a14f Czech Republic | |
| 14a868bd-0026-4761-a055-ed5d5298cdd5 Belgium | |
| Environmental | |
| Environmental Information | 9AKK10103A1058 |
| 9AKK108467A6707 | |
| Ordering | |
| E-Number (Finland) | 3655427 |
| EAN | 8015644627454 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 12 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 14 kg |
| Package Level 1 EAN | 8015644627454 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T6 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | at Rated Operating Conditions per Pole 32 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (690 V AC) 16.5 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 10 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (690 V AC) 22 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | PR221DS-LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | T6 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210015D0201 |
| Declaration of Conformity - CE | 9AKK106713A5538 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH000511R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |