View larger
1SDA060279R1 ABB T6S 800 PR221DS-I In 800 3p F F
1SDA060279R1
060279
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
T6
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing reliable short-circuit protection, the ABB T6S 800 PR221DS-I In 800 3p F F operates as a molded case circuit breaker designed to interrupt high fault currents in heavy electrical installations. Such breakers are widely integrated into commercial power distribution panels to isolate faulted circuits instantly.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: cfe6c2f5-86c4-4a5d-a935-32cfbfe189ac China
- Simplified SCIP: 8a918250-dd47-4bfa-9773-a3b291812b69 Portugal
- Environmental Information: 9AKK10103A1058
- EAN: 8015644627416
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 210 mm
- Product Net Height: 268 mm
- Product Net Depth / Length: 103.5 mm
- Product Net Weight: 9.5 kg
- Package Level 1 Units: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | cfe6c2f5-86c4-4a5d-a935-32cfbfe189ac China |
| Simplified SCIP | 8a918250-dd47-4bfa-9773-a3b291812b69 Portugal |
| b61d2cf6-9666-46dc-95ca-68e76c642d95 Czech Republic | |
| 6dcd615e-5628-4678-84b2-071cc5bb9ffc Bulgaria | |
| 92ec1a3f-e9a9-4047-a61b-fcc555f9e9aa Sweden | |
| 6c1e2579-2275-4450-9f42-f161c3640823 Poland | |
| 7ef870b1-8165-41d3-822b-50af44d44758 France | |
| 5fac7a06-6b2c-4e11-9a9e-1224e91502ce Sweden | |
| 82e1ea48-a91a-473b-8bb3-15938f71c10c Germany | |
| 17c02c45-6793-4714-92f1-b20a2a786046 Spain | |
| 01a09b51-7ca9-4dbc-b9a3-7c251bc0bb0e Poland | |
| 2e83c93a-414a-4fb8-a182-cb99ddf54f17 Germany | |
| ffac56bc-def8-4ba5-9a6c-6f8f61cbb3ed Germany | |
| 736ed53a-c53d-457a-926c-e08679e8f9a7 Norway | |
| 9716aa9e-daba-4176-bb3c-b8f88f958f8e Germany | |
| 5e5214c1-cae2-41c9-84c1-961c8da9c30c Poland | |
| d6caa506-c160-4f52-9167-2a9d5b3cac0a France | |
| 8df0d69d-b9d9-48b3-89d5-013acb6453f8 Hungary | |
| 65480c23-57ed-4a72-b6f3-70e04d846a02 Greece | |
| 4faba6ba-aeee-4ca7-a568-d2e1e2ce7e97 Denmark | |
| 48140baf-4ceb-4def-9285-1f9155d68292 Finland | |
| b701693b-7247-41a6-b810-68e52cb6dd36 Germany | |
| 3ae27951-061d-47a7-beae-3914cd275124 Netherlands | |
| c2a8d42e-1495-4304-940c-f3a707ca9ec7 Belgium | |
| Environmental | |
| Environmental Information | 9AKK10103A1058 |
| 9AKK108467A6707 | |
| Ordering | |
| EAN | 8015644627416 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 9.5 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 11 kg |
| Package Level 1 EAN | 8015644627416 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T6 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | at Rated Operating Conditions per Pole 32 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (690 V AC) 16.5 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 10 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (690 V AC) 22 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | PR221DS-I |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | T6 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210015D0201 |
| Declaration of Conformity - CE | 9AKK106713A5538 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH000511R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |