View larger
1SDA060241R1 ABB T6S 630 PR221DS-LS/I In 630 4p F F
1SDA060241R1
060241
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
T6
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Safeguarding heavy electrical distribution networks, an ABB T6S 630 PR221DS-LS/I In 630 4p F F molded case circuit breaker interrupts high fault currents reliably. Industrial switchgear setups rely on such multi-pole breakers to prevent equipment damage and ensure personnel safety. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 01e461c4-d9af-4e8e-a78e-84ea38f6a238 China
- Simplified SCIP: f2f27b38-7c09-4ebe-b49d-4bfcf4d6e7e5 Finland
- Environmental Information: 9AKK10103A1058
- E-Number (Finland): 3655426
- EAN: 8015644627034
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 280 mm
- Product Net Height: 268 mm
- Product Net Depth / Length: 103.5 mm
- Product Net Weight: 12 kg
More info
▲| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 01e461c4-d9af-4e8e-a78e-84ea38f6a238 China |
| Simplified SCIP | f2f27b38-7c09-4ebe-b49d-4bfcf4d6e7e5 Finland |
| 254fcf01-a48f-4c70-bc16-6ab01656ae4f Greece | |
| 00745f6e-2060-4ece-8ec0-253e1e2d8786 Belgium | |
| ef932ed7-c8ce-4ec9-ab3f-5610655ae124 Netherlands | |
| 03a97a87-bde8-4708-8d8b-7c36a0aa78ec France | |
| 22878a0b-8eef-474d-86aa-87e60d610b7e Poland | |
| 4d7e8e78-9dea-4d60-b28d-1657e368feaf Germany | |
| f56d45e1-3a35-4075-a3c6-d94dda7ace2f France | |
| dabdfe1f-bae6-4365-ae9d-7f75fc9ababc Sweden | |
| b0a1797f-4757-4f7c-ad91-3e21384ad156 Germany | |
| b54c7bab-0c78-448b-b9ba-c2cffc8ec158 Poland | |
| c1c5a7f9-2164-4c2e-ba0a-1d2cc75a3762 Sweden | |
| b20ee0b6-a492-492e-817f-6aee2e9e3eb9 Bulgaria | |
| 13682023-3571-48ed-aee4-a57176d4a21e Czech Republic | |
| 49e595ef-a696-440e-8b8f-dfa3265b414e Portugal | |
| a478f82d-8915-4727-97e6-67f66a0594d8 Spain | |
| 4e4238c6-d302-484d-a581-daf6ff3fc0b2 Germany | |
| b6a17b33-096c-44a4-828a-1477ff281114 Hungary | |
| e3eaf83c-56a4-49b9-82b4-25ad63681c64 Germany | |
| 0315e638-8e75-428b-85f4-0a084cd0ee8b Denmark | |
| e1a4933b-3335-4683-907c-8b058c4f60be Germany | |
| db30c96f-eb69-418f-83fb-a3e08ed6ff65 Norway | |
| dd719d7e-1a05-406b-ac9b-77b8a6bf651c Poland | |
| Environmental | |
| Environmental Information | 9AKK10103A1058 |
| 9AKK108467A6707 | |
| Ordering | |
| E-Number (Finland) | 3655426 |
| EAN | 8015644627034 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 12 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 14 kg |
| Package Level 1 EAN | 8015644627034 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T6 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | at Rated Operating Conditions per Pole 20 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (690 V AC) 16.5 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 7.6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (690 V AC) 22 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Release | PR221DS-LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | T6 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210015D0201 |
| Declaration of Conformity - CE | 9AKK106713A5538 |
| Instructions and Manuals | 1SDH000511R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |