1SDA060264R1 ABB T6L 630 PR222DS/P-LSI In 630 4p F F
1SDA060264R1
060264
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
T6
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
ABB T6L 630 PR222DS/P-LSI In 630 4p F F is a molded case circuit breaker designed to manage and protect heavy electrical distribution networks from overloads and short circuits. Such devices ensure rapid disconnection during fault conditions to prevent equipment damage. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: b6e7ffb6-434c-454d-a9db-f10a86d05471 China
- Simplified SCIP: 15a1457c-bb23-4dd0-a6e2-4b22c193a865 Netherlands
- Environmental Information: 9AKK10103A1058
- E-Number (Finland): 3655456
- EAN: 8015644627263
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 280 mm
- Product Net Height: 268 mm
- Product Net Depth / Length: 103.5 mm
- Product Net Weight: 12 kg
More info
▲| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | b6e7ffb6-434c-454d-a9db-f10a86d05471 China |
| Simplified SCIP | 15a1457c-bb23-4dd0-a6e2-4b22c193a865 Netherlands |
| 118f3cd5-8d01-49d7-a1ab-2ab13a76b34b Hungary | |
| 03dcc56a-874a-4569-b42e-9aa6dec5164d Estonia | |
| 43a357f1-b659-4933-85b4-6d055b53aefc Greece | |
| 19a6d9b2-dde5-4948-9deb-294e7217accc Poland | |
| 612f08e4-72e1-4864-b31e-bf9668a388e3 Germany | |
| f72c9aab-f891-4c0b-89ef-3ef3ac1d93dd Denmark | |
| 546561e5-3337-4273-ba1b-bed00c9cc2ac Germany | |
| afa6917d-e8ac-44e3-ad28-d1615791e45c Sweden | |
| 9512aeac-6c13-4ca9-b357-ca3063bbcb39 Germany | |
| 1a1d9597-83f5-4efe-9c77-9272a07ad053 France | |
| 73a003ef-f8b2-4287-aba6-522cc1addbcd Spain | |
| 222c4be8-00a7-427a-8b40-32358f55d81c Belgium | |
| 8436ac75-acfb-4412-a54b-c39fbbffe48d Poland | |
| 5a3aeee2-b0c5-49d2-8c50-5dcb66a95327 Sweden | |
| 9765a478-e83e-4d41-8726-9bf67013f63f Portugal | |
| 47c3b25d-cd9e-40f2-be2a-80f167ded9a5 Bulgaria | |
| 515f8480-c491-4939-83d1-3edeaeddf895 France | |
| 833ff62e-a4b7-47b0-aad9-18361d53b41d Germany | |
| 183525cc-64dc-4c8c-8edb-ad1c54c032e0 Hungary | |
| 838d6da9-1fdf-4edb-bd01-a8b84cb9d6e4 Croatia | |
| 197f6ce3-fb26-4f6e-8900-78a2fe9bb7de Germany | |
| 98514c4b-f8f8-4cea-aea3-245fa89c9909 Poland | |
| 0754e522-45f8-4a53-a570-785ebdc427fe Czech Republic | |
| fd760af1-eab8-4ac2-b28d-328725d13c1a Norway | |
| d97ae532-8018-4e23-bbc4-3678f2fe38e7 Belgium | |
| 33648a3c-3f6d-4c32-b3c2-5c609926f141 Finland | |
| Environmental | |
| Environmental Information | 9AKK10103A1058 |
| 9AKK108467A6707 | |
| Ordering | |
| E-Number (Finland) | 3655456 |
| EAN | 8015644627263 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 12 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 14 kg |
| Package Level 1 EAN | 8015644627263 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T6 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | at Rated Operating Conditions per Pole 20 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA |
| (230 V AC) 150 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 60 kA | |
| (500 V AC) 49 kA | |
| (690 V AC) 22.5 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 7.6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 80 kA | |
| (500 V AC) 65 kA | |
| (690 V AC) 30 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Release | PR222DS/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | L |
| Standards | IEC |
| Sub-type | T6 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210015D0201 |
| Declaration of Conformity - CE | 9AKK106713A5538 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH000511R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |