View larger
1SDA060258R1 ABB T6L 630 PR222DS/P-LSI In 630 3p F F
1SDA060258R1
060258
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
T6
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A high-capacity interrupting device, the ABB T6L 630 PR222DS/P-LSI In 630 3p F F circuit breaker provides precise overcurrent protection for critical industrial installations. These robust breakers are integrated into electrical switchgear to safely disconnect circuits during overloads and short circuits.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 81ff7f4b-ab0a-4540-8fc3-ae47a2afb2b7 China
- Simplified SCIP: bf389e57-9f1f-4bc6-8729-feaf791d87ef Poland
- Environmental Information: 9AKK10103A1058
- E-Number (Finland): 3655444
- EAN: 8015644627201
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 210 mm
- Product Net Height: 268 mm
- Product Net Depth / Length: 103.5 mm
- Product Net Weight: 9.5 kg
More info
▲| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 81ff7f4b-ab0a-4540-8fc3-ae47a2afb2b7 China |
| Simplified SCIP | bf389e57-9f1f-4bc6-8729-feaf791d87ef Poland |
| 1d9aa7f1-3a0d-4ff4-8309-91f65088edb3 Hungary | |
| 1bd44638-1d82-4635-8203-0f2b88c801e5 Netherlands | |
| 782a67a5-8596-425e-8e92-f5de9cdfcb6a Germany | |
| 4fe5c61d-78eb-4f53-94c1-c973d4944d93 Germany | |
| 52294ef3-edbb-44f8-97ce-99d57ac5d7df Denmark | |
| be02273f-1b90-4369-bb29-e4efb7b463b0 Finland | |
| 3cd6515e-5b7f-44ee-bfe7-7f59fd94d4b9 Belgium | |
| befc6fb2-d717-4d9e-a989-6f2532d15690 France | |
| 5695c7f7-4f9e-495d-b10b-a42c0533e127 Poland | |
| baa0e93d-6c7c-4979-84b8-d126fc8028b6 Sweden | |
| aa4a690c-5040-4de0-a041-407b764bb0e7 Bulgaria | |
| 0be4b486-6128-4b3e-9839-5af5a58054fc Estonia | |
| 79c28201-a558-413b-8dc3-8180572cb589 Greece | |
| af93ba85-bd25-41fa-9d9b-116e8995fc43 Portugal | |
| 275c2a62-6345-4106-b8f8-7ca40631835a Belgium | |
| 5eee8c03-024a-4cb8-89c9-c9d93c787f08 France | |
| 43ce302d-97de-4a44-b86f-39ad74c3e6cd Germany | |
| 174333bb-03c3-4353-b9bf-7ad35a6f3312 Sweden | |
| 4971a68e-d83c-4f9d-956e-b1e10901ed66 Germany | |
| 70d6a8db-4634-4d96-824d-598d90d56d75 Spain | |
| fc9b4449-d5d8-430c-90c6-cdbccd902759 Norway | |
| 039d8747-efdc-45b8-b8b9-27656e51b39a Czech Republic | |
| 25cfffa7-ff71-4b96-89cd-24d8d2e04f86 Poland | |
| cd2d859c-74b2-46bb-80ed-48464c2826de Croatia | |
| 82ed4d91-98d1-4f0c-b447-d4d3952e3dea Germany | |
| 16ecc69b-4d95-490a-84cf-66db9750e7bf Hungary | |
| Environmental | |
| Environmental Information | 9AKK10103A1058 |
| 9AKK108467A6707 | |
| Ordering | |
| E-Number (Finland) | 3655444 |
| EAN | 8015644627201 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 9.5 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 11 kg |
| Package Level 1 EAN | 8015644627201 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T6 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | at Rated Operating Conditions per Pole 20 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA |
| (230 V AC) 150 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 60 kA | |
| (500 V AC) 49 kA | |
| (690 V AC) 22.5 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 7.6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 80 kA | |
| (500 V AC) 65 kA | |
| (690 V AC) 30 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Release | PR222DS/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | L |
| Standards | IEC |
| Sub-type | T6 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210015D0201 |
| Declaration of Conformity - CE | 9AKK106713A5538 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH000511R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |