1SDA060246R1 ABB T6H 630 PR221DS-LS/I In 630 3p F F
1SDA060246R1
060246
ABB
1 Pcs.
T6H 630 PR221DS-LS/I In=630 3p F F
T6H630 PR221DS LS/I R630 3P F F
Automation > Power circuit-breaker for trafo/generator/installation protection
T6
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
1SDA060246R1 ABB T6H 630 PR221DS-LS/I In 630 3p F F is a molded case circuit breaker used in commercial and industrial settings to protect power distribution circuits and connected equipment from electrical hazards.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 8c3e7d24-7b22-44e4-bb49-e2d8b8572d75 China
- Simplified SCIP: 37a355d2-88eb-4278-810a-5d506ab068cb Poland
- Environmental Information: 9AKK10103A1058
- E-Number (Finland): 3655417
- EAN: 8015644627089
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 210 mm
- Product Net Height: 268 mm
- Product Net Depth / Length: 103.5 mm
- Product Net Weight: 9.5 kg
More info
▲| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 8c3e7d24-7b22-44e4-bb49-e2d8b8572d75 China |
| Simplified SCIP | 37a355d2-88eb-4278-810a-5d506ab068cb Poland |
| 069cc80a-ece9-438a-84b3-00c6c9c7519a Germany | |
| ec244e3b-cc94-4210-ae0d-438f146d04ee Norway | |
| db99316d-7adf-4def-8c03-fe03f3b3b463 Netherlands | |
| 63174ead-4d3d-4e4e-9afb-24f7f5cdfecf France | |
| 89932a2b-6bd3-45e0-a462-22c2966cf68d Finland | |
| 82d082dc-0909-4872-994d-aa41060209d0 Sweden | |
| 78c092b9-9cfd-473d-bfd0-0b9ec27fe8fa Germany | |
| 284041e5-9d3f-45df-9b26-62b9681338b2 Germany | |
| 25822bc1-0615-4543-a44e-0174b8327f46 Denmark | |
| 5887c392-f426-4272-8d6a-82643960cfc1 France | |
| 9618a3d1-a51f-4487-bb66-c25b310b8857 Germany | |
| c5d4e539-5250-4d72-8d5e-ec6ff5714a7f Portugal | |
| dbc8b683-e99f-4392-8c35-e813e058c6e1 Spain | |
| 3816645f-6834-4475-ba0c-828232763489 Germany | |
| 1d4499a6-27e9-42d1-98c1-6083479e2623 Hungary | |
| 742134a1-8e09-4376-8eba-0e5e5043d16a Greece | |
| e6061782-2bd7-4599-a0ea-616018551cb1 Belgium | |
| bebff13a-62df-40a4-8e26-b06c8e075abc Poland | |
| 5a1b1b82-8d02-434b-a27e-fcd7ab8ab3bb Czech Republic | |
| 5a362f38-bf83-4493-baa3-d9a05c145083 Poland | |
| 59067d82-889c-4d61-8695-8ca89b499ec7 Sweden | |
| 1a738a63-f0fd-4c43-9325-fb6ca1f0cbf4 Bulgaria | |
| Environmental | |
| Environmental Information | 9AKK10103A1058 |
| 9AKK108467A6707 | |
| Ordering | |
| E-Number (Finland) | 3655417 |
| EAN | 8015644627089 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 9.5 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 11 kg |
| Package Level 1 EAN | 8015644627089 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T6 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | at Rated Operating Conditions per Pole 20 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (400 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (690 V AC) 19 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 7.6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (400 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (690 V AC) 25 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Release | PR221DS-LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | T6 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210015D0201 |
| Declaration of Conformity - CE | 9AKK106713A5538 |
| Instructions and Manuals | 1SDH000511R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |