View larger
1SDA054429R1 ABB T5V 630 PR221DS-I In 630 3p F F
1SDA054429R1
054429
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
T5
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb 1SDA054429R1 ABB T5V 630 PR221DS-I In 630 3p F F is a molded case circuit breaker engineered to protect electrical distribution systems against overloads and short circuits. Units of this type are typically installed in industrial switchboards and control panels to safely interrupt fault currents and isolate downstream loads during maintenance or electrical anomalies.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: ad243b64-2450-4d03-b2d1-87e43095d492 China
- Simplified SCIP: 372558a6-5a6a-4eb0-900f-cc5d27f2f549 Germany
- Environmental Information: 9AKK10103A1056
- E-Number (Finland): 3655541
- EAN: 8015644555337
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 140 mm
- Product Net Height: 205 mm
- Product Net Depth / Length: 103.5 mm
- Product Net Weight: 5.1 kg
More info
▲| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | ad243b64-2450-4d03-b2d1-87e43095d492 China |
| Simplified SCIP | 372558a6-5a6a-4eb0-900f-cc5d27f2f549 Germany |
| b7b766e8-0d3c-43d8-907d-13f4134f120e Portugal | |
| c94bab6e-2d23-4070-9e54-61f08859de58 Finland | |
| fe74fbb6-d5c1-40ab-9433-ed3f6bed6bb3 Germany | |
| c01047f7-d5e5-4f49-9d86-c09b1dc69412 Spain | |
| 8abd21d0-5776-4db7-8dff-06fcb3915cfa Greece | |
| 1c65f4cf-f75a-4f3c-b6d1-63ef1a591494 Hungary | |
| fac584f2-5f45-4b08-a9af-cf15805b5be5 Poland | |
| 5fa1511d-4d14-478a-8035-f5b0367975bf France | |
| 5cd6f70f-b713-4a70-a419-d36a961c6c81 Norway | |
| da329e96-b2ef-44c7-9cc3-8851c92e409c Germany | |
| 5c26923c-2048-4482-bb32-2cb4d30ba5f4 Denmark | |
| 77023068-7589-4447-841c-c89cee94ea58 Germany | |
| 91bbcdfd-096c-4368-ac12-2706be869ec3 Germany | |
| a29147b7-e823-48b3-9d7f-75a950c6ee71 Sweden | |
| 4c5c89a1-a79f-4aa7-9fdb-15b9d5f607fc France | |
| 31cc04a8-3f02-45e8-a68f-cfcad1759c25 Netherlands | |
| c3355781-46d8-467e-bfa5-b896b26469f5 Belgium | |
| 7bdff1c6-a3a9-42a4-ae1e-747e6fed17b6 Poland | |
| 401c7be7-185e-4dad-a228-3737a374a8d3 Bulgaria | |
| ba588bbb-d3ac-4a1f-aa6b-f7e7004ae926 Sweden | |
| 6513fcc8-da90-4457-b967-0280dda3c599 Poland | |
| 3bf17cea-9201-4b74-bccb-418773573682 Czech Republic | |
| Environmental | |
| Environmental Information | 9AKK10103A1056 |
| 9AKK108467A6707 | |
| Ordering | |
| E-Number (Finland) | 3655541 |
| EAN | 8015644555337 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 5.1 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 248 mm |
| Package Level 1 Height | 240 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 5.1 kg |
| Package Level 1 EAN | 8015644555337 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T5 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | at Rated Operating Conditions per Pole 41 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (380 V AC) 200 kA | |
| (400 V AC) 200 kA | |
| (415 V AC) 200 kA | |
| (440 V AC) 180 kA | |
| (500 V AC) 75 kA | |
| (690 V AC) 40 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (380 V AC) 200 kA | |
| (400 V AC) 200 kA | |
| (415 V AC) 200 kA | |
| (440 V AC) 180 kA | |
| (500 V AC) 150 kA | |
| (690 V AC) 80 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Release | PR221DS-I |
| Release Type | EL |
| Short-Circuit Performance Level | V |
| Standards | IEC |
| Sub-type | T5 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Test Voltage at Industrial Frequency for 1 Minute | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210004D0203 |
| Declaration of Conformity - CE | 9AKK106713A5539 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| GL Certificate | 1SDL000163R0062 |
| Instructions and Manuals | 1SDH000437R0001 |
| Instructions and Manuals (Part 2) | ITSCE-RH0100001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |