View larger
1SDA054436R1 ABB T5N 400 TMA 320-3200 3p F F
1SDA054436R1
054436
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
T5
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A molded case circuit breaker of this configuration provides essential overcurrent and short-circuit protection for heavy-duty industrial power distribution architecture. Industrial installations deploy these devices to safeguard heavy machinery, transformers, and electrical feeders against electrical overloads and sudden faults. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 8cdc5dd9-37b5-46ba-99cf-a7632c1ce87a Italy
- Simplified SCIP: 64a8bed2-933f-43f1-8547-5f29a249de34 Germany
- Environmental Information: 9AKK10103A1056
- E-Number (Finland): 3655291
- E-Number (Norway): 4384082
- EAN: 8015644555405
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 140 mm
- Product Net Height: 205 mm
- Product Net Depth / Length: 103.5 mm
More info
▲| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 8cdc5dd9-37b5-46ba-99cf-a7632c1ce87a Italy |
| Simplified SCIP | 64a8bed2-933f-43f1-8547-5f29a249de34 Germany |
| 72bfab1e-8275-4104-a336-dced45670e46 Poland | |
| 419b35e4-6d60-42c8-8769-79e14387a0f0 Finland | |
| 72d40195-278e-4462-86a8-30128e255082 France | |
| 863ca969-e787-4d4d-8331-c06b9574fb72 Germany | |
| b43a9e51-4cab-4ff1-97e5-138a1dcf1f92 Germany | |
| 8eafb782-c1a6-42c0-8dc8-65e9fc699fd1 Sweden | |
| 03b3003a-d2cf-4c2a-960f-33800918712d France | |
| b6a12bdd-0f20-48c5-a3b5-19e522d32ac2 Poland | |
| 1396c4f2-6bce-46c3-9ef3-f05ddd9332fb Sweden | |
| 4000a525-f831-475d-b10f-13fabfa46128 Bulgaria | |
| df2d48a6-809f-4a10-b5a7-044dda6b5a9f Portugal | |
| 800c7c5f-db41-4044-bd10-f0f2c277d08e Greece | |
| ae67131f-c4dc-44da-98fe-7fb0112f12fb Estonia | |
| 128ec7cc-7a12-4297-875d-ff872e25b5f0 Netherlands | |
| 1eb62259-6fa6-4177-9e3a-d9b2754f63c1 Netherlands | |
| c11d3463-2120-401c-a37d-175062353606 Poland | |
| f28ad8fd-93c5-4d8c-b9d9-855f50e44dfd Czech Republic | |
| 9eea24e1-4a7e-43d1-bacb-6cb0fc898b96 Denmark | |
| 602cb388-99e2-4d98-9428-fe616cb082ec Norway | |
| bcc60dbf-7cf5-4f78-ac93-bd8a09a7e4fc Croatia | |
| e9c54079-24af-43f2-8ec5-c24fac2e16cc Germany | |
| 7485128b-bc8f-4cc4-bcf9-37cf9176c83a Germany | |
| c0ca1704-6790-4b0e-91cb-f1bfdf19cd49 Netherlands | |
| 0d1a14a8-f3a8-4261-82c9-516856b2b523 Netherlands | |
| 8e345532-cb13-4f3c-8b5e-06f686266510 Netherlands | |
| 65443fe6-c0e9-44cd-83c9-5e659510fa4d Spain | |
| Environmental | |
| Environmental Information | 9AKK10103A1056 |
| 9AKK108467A6707 | |
| Ordering | |
| E-Number (Finland) | 3655291 |
| E-Number (Norway) | 4384082 |
| EAN | 8015644555405 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 4.494 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 248 mm |
| Package Level 1 Height | 240 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 4.8 kg |
| Package Level 1 EAN | 8015644555405 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T5 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | at Rated Operating Conditions per Pole 13.6 W |
| Rated Current (In) | 320 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 750 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (400 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 30 kA | |
| (500 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 5 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (400 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 30 kA | |
| (500 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 2 Poles in Series 25 kA | |
| (750 V DC) 3 Poles in Series 16 kA | |
| Rated Uninterrupted Current (Iu) | 400 A |
| Release | TMA |
| Release Type | TM |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | T5 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Test Voltage at Industrial Frequency for 1 Minute | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210004D0203 |
| Declaration of Conformity - CE | 9AKK106713A5539 |
| Instructions and Manuals | 1SDH000437R0001 |
| Instructions and Manuals (Part 2) | ITSCE-RH0100001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |