View larger
1SDA063415R1 ABB T4V 250 TMA 160-1600 3p F FC 1150V AC
1SDA063415R1
063415
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
T4
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB T4V 250 molded case circuit breaker provides high-performance protection for demanding industrial electrical circuits against short circuits and overloads. It ensures safe interruption of high fault currents to maintain the integrity of electrical distribution systems.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: ee7d7399-c9c7-4af4-9973-99d1bcbd3c72 Italy
- Simplified SCIP: f4f59e17-c41a-478a-b1fa-17fe17a3c2a7 Germany
- Environmental Information: 9AKK10103A1057
- EAN: 8015644660345
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85352100
- Product Net Width: 105 mm
- Product Net Height: 205 mm
- Product Net Depth / Length: 103.5 mm
- Product Net Weight: 2.35 kg
- Package Level 1 Units: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | ee7d7399-c9c7-4af4-9973-99d1bcbd3c72 Italy |
| Simplified SCIP | f4f59e17-c41a-478a-b1fa-17fe17a3c2a7 Germany |
| b27dc842-acdf-408b-b930-51b0245c8863 France | |
| 0c96473e-981c-4574-9e77-e2668d0bdc3f Netherlands | |
| f0ec9bae-e331-460a-bea1-96b80df18949 Spain | |
| e1e6a134-2bad-4caa-a564-1971c6274d18 Netherlands | |
| cb4fe2d3-66d9-4fa7-abfd-1ea897375872 Poland | |
| 7d62b552-8338-4c95-9acc-9529bb6da742 Norway | |
| 93ab74c0-cdf4-4fcf-8d6f-d5fa8b457ad6 Finland | |
| 04e054fe-fafe-4c85-86b7-d3bd04f5e248 Netherlands | |
| be3d1c1e-4508-46c6-8267-9a53993b7eaf Netherlands | |
| a768e7e0-6c5e-4d41-9589-beb969e20e77 Estonia | |
| 9d1bda2c-0489-40ad-959d-936688342d57 Greece | |
| a2db3d83-07b2-4af3-9bb8-7e93265a6e07 Portugal | |
| ce4c37d4-8536-4811-bd07-e908b819c146 Bulgaria | |
| fc1684b9-c24e-45ca-8164-bd0bcd7eb313 Sweden | |
| 4e7f1b61-3dd5-40e5-8b97-fb39a0790480 Poland | |
| d0690f4d-4852-44a0-8e75-859e057e10e4 France | |
| 7028dd79-d606-4f8b-9856-b38aea65fe98 Sweden | |
| 5e55bfa1-d0e5-42b0-835c-0c5f0b4d72f4 Germany | |
| 35e7f2f3-f6f3-4e06-8790-f5de429732ea Germany | |
| 6df2bb81-913b-46e2-83ea-e098e67b813f Germany | |
| 9e5c3be5-13ad-4901-bf58-cc52ccc4ad45 Denmark | |
| 422deda8-89fd-4d61-8442-5343c9908a8d Germany | |
| 8035acb1-98b5-4c89-b2fd-a78368d185bb Croatia | |
| 14508eee-f636-4fff-b6dc-a9333d0b93dc Czech Republic | |
| 696fee27-fe6f-41de-bcbc-82e50122291c Poland | |
| dd671326-3c5d-4115-930c-77cff342a839 Netherlands | |
| Environmental | |
| Environmental Information | 9AKK10103A1057 |
| 9AKK108467A6707 | |
| Ordering | |
| EAN | 8015644660345 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85352100 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 2.35 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 248 mm |
| Package Level 1 Height | 240 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 2.5 kg |
| Package Level 1 EAN | 8015644660345 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| Technical | |
| Number of Poles | 3P |
| Power Loss | at Rated Operating Conditions per Pole 7.4 W |
| Rated Current (In) | 160 A |
| Rated Operational Voltage | 1150 V AC |
| 1000 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (1000 V AC) 12 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (415 V AC) 200 kA |
| (1000 V AC) 20 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Release | TMA |
| Release Type | TM |
| Short-Circuit Performance Level | V |
| Standards | IEC |
| Sub-type | T4 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front for Copper Cables | |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210300D0201 |
| Declaration of Conformity - CE | 9AKK106713A5540 |
| GL Certificate | 1SDL000163R0061 |
| Instructions and Manuals | 1SDH000457R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |