View larger
2CCS864001R0164 ABB S804S-C16 High Performance Circuit Breaker
2CCS864001R0164
864001
ABB
1 Pcs.
Automation > Miniature circuit breaker (MCB)
S800S
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Protection against damaging overcurrent conditions in heavy-duty setups is provided by the 2CCS864001R0164 Abb S804S-C16 High Performance Circuit Breaker. Circuit breakers are deployed in electrical distribution infrastructure to automatically disconnect power during fault states, preventing equipment damage and electrical fires.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Built-in depth (EF000218): 82.5 mm
- Release characteristic (EF000889): C
- Number of poles (total) (EF008618): 4
- Number of protected poles (EF005548): 4
- Rated current (EF000227): 16 A
- Rated voltage (EF000228): 400 V
- Rated insulation voltage Ui (EF001366): 690 V
- Rated impulse withstand voltage Uimp (EF011980): 8 kV
- Voltage type (EF000187): AC/DC
- Frequency (EF000416): 50 Hz
- Current limiting class (EF002568): 3
- Flush-mounted installation (EF007517): No
- Concurrently switching neutral conductor (EF005997): No
- Over voltage category (EF002569): 4
- Pollution degree (EF002570): 3
- Additional equipment possible (EF008148): Yes
More info
▲The S804S-C16 is a 4-pole High Performance Circuit breaker with C-characteristic, with cage terminal and a rated current of 16 A. It is a current limiting device with a maximum breaking capacity of 50kA at 240/415V. It can be used for voltages up to 400/690V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S804S-C16 complies with IEC/EN 60898-1 and IEC/EN 60947-2 and allows the use for residential, commercial and industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S804S-C16 more comfortable. Due to the fast arc extinction of S804S-C16 your application will be secured.
Ordering
- EAN:
- 7612271200862
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85362020
Dimensions
- Product Net Width:
- 106mm
- Product Net Depth:
- 82.5mm
- Product Net Height:
- 95mm
- Product Net Weight:
- 0.98kg
Container Information
- Package Level 1 Units:
- 1 piece
- Package Level 1 Width:
- 105 mm
- Package Level 1 Length:
- 111 mm
- Package Level 1 Height:
- 99 mm
- Package Level 1 Gross Weight:
- 1.01 kg
- Package Level 1 EAN:
- 7612271200862
- Package Level 2 Units:
- 1
Environmental
- Ambient Air Temperature:
- Operation -25 ... +60 °C
Storage -40 ... +70 °C
- Resistance to Vibrations acc. to IEC 60068-2-6:
- 2 - 13.2 Hz / 1mm
13.2 - 100Hz / 0.7g
with load 100% x Ie
- Environmental Conditions:
- Damp Heat Cyclic acc. to IEC 60068-2-30 12+12 cycle
Damp Heat Cyclic acc. to IEC 60068-2-30 55°C @ 90-96%
Damp Heat Cyclic acc. to IEC 60068-2-30 25°C @ 90-100%
Dry Heat Test B acc. to IEC 60068-2-2 16 hour @ 55 °C
Dry Heat Test B acc. to IEC 60068-2-2 2 hour @ 70 °C
- RoHS Status:
- Following EU Directive 2002/95/EC August 18, 2005 and amendment
Technical
- Standards:
- IEC/EN 60947-2 IEC/EN 60898-1
- Number of Poles:
- 4
- Tripping Characteristic:
- C
- Rated Current (In):
- 16 A
- Rated Operational Voltage:
- 400/690 V AC
375 V DC
- Power Loss:
- at Rated Operating Conditions per Pole 3.1 W
- Rated Insulation Voltage (Ui):
- 690 V AC
- Operational Voltage:
- Maximum 230/400 V AC
Minimum 12 V AC
- Rated Frequency (f):
- 50 / 60 Hz
- Rated Short-Circuit Capacity (Icn):
- (230 / 400 V AC) 25 kA
- Rated Ultimate Short-Circuit Breaking Capacity (Icu):
- (240 / 415 V AC) 50 kA
(254 / 440 V AC) 30 kA
(400 / 690 V AC) 6 kA
(125 V DC) 30 kA
- Rated Service Short-Circuit Breaking Capacity (Ics):
- (240 / 415 V AC) 40 kA
(254 / 440 V AC) 22.5 kA
(400 / 690 V AC) 4 kA
(125 V DC) 30 kA
- Energy Limiting Class:
- 3
- Overvoltage Category:
- IV
- Pollution Degree:
- 3
- Rated Impulse Withstand Voltage (Uimp):
- 8 kV
- Housing Material:
- Insulation group I, RAL 7035
- Contact Position Indication:
- ON / OFF / TRIP
- Degree of Protection:
- acc. to IEC 60529 IP20
- Remarks:
- Connection from top and bottom
Connecting with CU only
IP40 in enclosure with cover
Cage terminal with captive screw
- Electrical Endurance:
- 10000 cycle
- Mechanical Endurance:
- 10000 cycle
- Terminal Type:
- Screw Terminals
- Connecting Capacity:
- Stranded 1 ... 50 mm²
Flexible 1 …70 mm²
- Tightening Torque:
- 3.5 N·m
31 in·lb
- Recommended Screw Driver:
- Pozidriv 2
- Mounting on DIN Rail:
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Mounting Position:
- Any
Certificates and Declarations (Document Number)
- Declaration of Conformity - CE:
- 2CCC413016D060
- RoHS Information:
- 2CCC413008D0204
Classifications
- ETIM 4:
- EC000042 - Miniature circuit breaker (MCB)
- ETIM 5:
- EC000042 - Miniature circuit breaker (MCB)
- Object Classification Code:
- F