ABB 2CCS894001R0081 2CCS894001R0081 ABB S804N-D8 High Performance Circuit Breaker View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2CCS894001R0081 ABB S804N-D8 High Performance Circuit Breaker

2CCS894001R0081

894001

ABB

1 Pcs.

S804N-D8 High Performance Circuit Breaker Int. aut. S804N-D8 4P 8A D 36kA S804N-D8 High Performance MCB

Automation > Miniature circuit breaker (MCB)
S800N

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Protect heavy electrical distribution networks with the Abb 2CCS894001R0801 ABB S804N-D8 High Performance Circuit Breaker. Circuit breakers are deployed in industrial automation enclosures to automatically interrupt abnormal overcurrents or short circuits, safeguarding downstream machinery and wiring from thermal damage. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Ambient Air Temperature: Operation -25 ... +60 °C Storage -40 ... +70 °C
  • Resistance to Shock acc. to IEC 60068-2-27: 5 g 30 ms
  • Resistance to Vibrations acc. to IEC 60068-2-6: 2 - 13.2 Hz / 1mm 13.2 - 100Hz / 0.7g with load 100% x Ie
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Standards: IEC/EN 60947-2 IEC/EN 60898-1
  • Number of Poles: 4
  • Tripping Characteristic: D
  • Rated Current (I n ): 8 A
  • Rated Operational Voltage: 400/690 V AC 375 V DC
  • Power Loss: at Rated Operating Conditions per Pole 1.7 W
  • Rated Insulation Voltage (U i ): 690 V AC
  • Rated Frequency (f): 50 / 60 Hz
  • Rated Ultimate Short-Circuit Breaking Capacity (I cu ): (240 / 415 V AC) 36 kA (254 / 440 V AC) 20 kA (400 / 690 V AC) 4.5 kA (125 V DC) 20 kA
  • Rated Service Short-Circuit Breaking Capacity (I cs ): (240 / 415 V AC) 30 kA (254 / 440 V AC) 15 kA (400 / 690 V AC) 3 kA (125 V DC) 20 kA
  • Overvoltage Category: IV
  • Pollution Degree: 3

More info

▲

The S804N-D8 is a 4-pole High Performance Circuit breaker with D-Characteristic, with cage terminal and a rated current of 8 A. It is a current limiting device with a maximum breaking capacity of 36kA at 240/415V. It can be used for voltages up to 400/690V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S804N-D8 complies with IEC/EN 60947-2 and allows the use for industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S804N-D8 more comfortable. Due to the fast arc extinction of S804N-D8 your application will be secured.

Ordering

  • EAN:
    7612271411756
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85362020

Dimensions

  • Product Net Width:
    106mm
  • Product Net Depth:
    82.5mm
  • Product Net Height:
    95mm
  • Product Net Weight:
    0.98kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    105 mm
  • Package Level 1 Length:
    111 mm
  • Package Level 1 Height:
    99 mm
  • Package Level 1 Gross Weight:
    1.01 kg
  • Package Level 1 EAN:
    7612271411756

Environmental

  • Ambient Air Temperature:
    Operation -25 ... +60 °C
    Storage -40 ... +70 °C
  • Resistance to Shock acc. to IEC 60068-2-27:
    5 g
    30 ms
  • Resistance to Vibrations acc. to IEC 60068-2-6:
    2 - 13.2 Hz / 1mm
    13.2 - 100Hz / 0.7g
    with load 100% x Ie
  • Environmental Conditions:
    Damp Heat Cyclic acc. to IEC 60068-2-30 12+12 cycle
    Damp Heat Cyclic acc. to IEC 60068-2-30 55°C @ 90-96%
    Damp Heat Cyclic acc. to IEC 60068-2-30 25°C @ 90-100%
    Dry Heat Test B acc. to IEC 60068-2-2 16 hour @ 55 °C
    Dry Heat Test B acc. to IEC 60068-2-2 2 hour @ 70 °C
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical

  • Standards:
    IEC/EN 60947-2 IEC/EN 60898-1
  • Number of Poles:
    4
  • Tripping Characteristic:
    D
  • Rated Current (In):
    8 A
  • Rated Operational Voltage:
    400/690 V AC
    375 V DC
  • Power Loss:
    at Rated Operating Conditions per Pole 1.7 W
  • Rated Insulation Voltage (Ui):
    690 V AC
  • Rated Frequency (f):
    50 / 60 Hz
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):
    (240 / 415 V AC) 36 kA
    (254 / 440 V AC) 20 kA
    (400 / 690 V AC) 4.5 kA
    (125 V DC) 20 kA
  • Rated Service Short-Circuit Breaking Capacity (Ics):
    (240 / 415 V AC) 30 kA
    (254 / 440 V AC) 15 kA
    (400 / 690 V AC) 3 kA
    (125 V DC) 20 kA
  • Overvoltage Category:
    IV
  • Pollution Degree:
    3
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Housing Material:
    Insulation group I, RAL 7035
  • Contact Position Indication:
    ON / OFF / TRIP
  • Degree of Protection:
    acc. to IEC 60529 IP20
  • Remarks:
    Connection from top and bottom
    Connecting with CU only
    IP40 in enclosure with cover
    Cage terminal with captive screw
  • Electrical Endurance:
    10000 cycle
  • Mechanical Endurance:
    10000 cycle
  • Terminal Type:
    Screw Terminals
  • Connecting Capacity:
    Stranded 1 ... 50 mm²
    Flexible 1 …70 mm²
  • Tightening Torque:
    3.5 N·m
    31 in·lb
  • Recommended Screw Driver:
    Pozidriv 2
  • Mounting on DIN Rail:
    TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
    TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Mounting Position:
    Any

Certificates and Declarations (Document Number)

Classifications

  • ETIM 4:
    EC000042 - Miniature circuit breaker (MCB)
  • ETIM 5:
    EC000042 - Miniature circuit breaker (MCB)
  • Object Classification Code:
    F

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.