ABB S803N-D100 S803N-D100 2CCS893001R0821 ABB S803N-D100 High Performance Circuit Breaker View larger
Images are for illustrative purposes only. Please refer to data sheet for details

S803N-D100 2CCS893001R0821 ABB S803N-D100 High Performance Circuit Breaker

S803N-D100

2CCS893001R0821

ABB

1 Pcs.

S803N-D100 High Performance Circuit Breaker Int.aut. S803N-D100 3p 100A D 36kA

Automation > Miniature circuit breaker (MCB)
S800N

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Industrial power systems rely on the Abb S803N-D100 high performance circuit breaker to automatically isolate circuits during dangerous overcurrent conditions and short circuits. These protective switches prevent equipment damage and maintain the safety of complex electrical distribution networks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Ambient Air Temperature: Operation -25 ... +60 °C Storage -40 ... +70 °C
  • Resistance to Shock acc. to IEC 60068-2-27: 5 g 30 ms
  • Resistance to Vibrations acc. to IEC 60068-2-6: 2 - 13.2 Hz / 1mm 13.2 - 100Hz / 0.7g with load 100% x Ie
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Standards: IEC/EN 60947-2 IEC/EN 60898-1
  • Number of Poles: 3
  • Tripping Characteristic: D
  • Rated Current (I n ): 100 A
  • Rated Operational Voltage: 400/690 V AC 375 V DC
  • Power Loss: at Rated Operating Conditions per Pole 8 W
  • Rated Insulation Voltage (U i ): 690 V AC
  • Rated Frequency (f): 50 / 60 Hz
  • Rated Ultimate Short-Circuit Breaking Capacity (I cu ): (240 / 415 V AC) 36 kA (254 / 440 V AC) 20 kA (400 / 690 V AC) 4.5 kA (125 V DC) 30 kA
  • Rated Service Short-Circuit Breaking Capacity (I cs ): (240 / 415 V AC) 30 kA (254 / 440 V AC) 10 kA (400 / 690 V AC) 3 kA (125 V DC) 20 kA
  • Overvoltage Category: IV
  • Pollution Degree: 3

More info

▲

The S803N-D100 is a 3-pole High Performance Circuit breaker with D-Characteristic, with cage terminal and a rated current of 100 A. It is a current limiting device with a maximum breaking capacity of 36kA at 240/415V. It can be used for voltages up to 400/690V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S803N-D100 complies with IEC/EN 60947-2 and allows the use for industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S803N-D100 more comfortable. Due to the fast arc extinction of S803N-D100 your application will be secured.

Ordering

  • EAN:
    7612271205102
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85362020

Dimensions

  • Product Net Width:
    81mm
  • Product Net Depth:
    82.5mm
  • Product Net Height:
    95mm
  • Product Net Weight:
    0.74kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    105 mm
  • Package Level 1 Length:
    86 mm
  • Package Level 1 Height:
    99 mm
  • Package Level 1 Gross Weight:
    0.77 kg
  • Package Level 1 EAN:
    7612271205102
  • Package Level 2 Units:
    1

Environmental

  • Ambient Air Temperature:
    Operation -25 ... +60 °C
    Storage -40 ... +70 °C
  • Resistance to Shock acc. to IEC 60068-2-27:
    5 g
    30 ms
  • Resistance to Vibrations acc. to IEC 60068-2-6:
    2 - 13.2 Hz / 1mm
    13.2 - 100Hz / 0.7g
    with load 100% x Ie
  • Environmental Conditions:
    Damp Heat Cyclic acc. to IEC 60068-2-30 12+12 cycle
    Damp Heat Cyclic acc. to IEC 60068-2-30 55°C @ 90-96%
    Damp Heat Cyclic acc. to IEC 60068-2-30 25°C @ 90-100%
    Dry Heat Test B acc. to IEC 60068-2-2 16 hour @ 55 °C
    Dry Heat Test B acc. to IEC 60068-2-2 2 hour @ 70 °C
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical

  • Standards:
    IEC/EN 60947-2 IEC/EN 60898-1
  • Number of Poles:
    3
  • Tripping Characteristic:
    D
  • Rated Current (In):
    100 A
  • Rated Operational Voltage:
    400/690 V AC
    375 V DC
  • Power Loss:
    at Rated Operating Conditions per Pole 8 W
  • Rated Insulation Voltage (Ui):
    690 V AC
  • Rated Frequency (f):
    50 / 60 Hz
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):
    (240 / 415 V AC) 36 kA
    (254 / 440 V AC) 20 kA
    (400 / 690 V AC) 4.5 kA
    (125 V DC) 30 kA
  • Rated Service Short-Circuit Breaking Capacity (Ics):
    (240 / 415 V AC) 30 kA
    (254 / 440 V AC) 10 kA
    (400 / 690 V AC) 3 kA
    (125 V DC) 20 kA
  • Overvoltage Category:
    IV
  • Pollution Degree:
    3
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Housing Material:
    Insulation group I, RAL 7035
  • Contact Position Indication:
    ON / OFF / TRIP
  • Degree of Protection:
    acc. to IEC 60529 IP20
  • Remarks:
    Connection from top and bottom
    Connecting with CU only
    IP40 in enclosure with cover
    Cage terminal with captive screw
  • Electrical Endurance:
    6000 cycle
  • Mechanical Endurance:
    4000 cycle
  • Terminal Type:
    Screw Terminals
  • Connecting Capacity:
    Stranded 1 ... 50 mm²
    Flexible 1 …70 mm²
  • Tightening Torque:
    3.5 N·m
    31 in·lb
  • Recommended Screw Driver:
    Pozidriv 2
  • Mounting on DIN Rail:
    TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
    TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Mounting Position:
    Any

Certificates and Declarations (Document Number)

Classifications

  • ETIM 4:
    EC000042 - Miniature circuit breaker (MCB)
  • ETIM 5:
    EC000042 - Miniature circuit breaker (MCB)
  • Object Classification Code:
    F

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.