ABB 2CCS883001R0321 2CCS883001R0321 ABB S803C-D32 High Performance Circuit Breaker View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2CCS883001R0321 ABB S803C-D32 High Performance Circuit Breaker

2CCS883001R0321

883001

ABB

1 Pcs.

S803C-D32 High Performance Circuit Breaker Int.aut. S803C-D32 3p 32A D 25kA S803C-D32 High Performance MCB

Automation > Miniature circuit breaker (MCB)
S800C

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Heavy-duty industrial power distribution systems utilize the Abb 2CCS883001R0321 S803C-D32 High Performance Circuit Breaker to interrupt high fault currents and protect critical machinery. These high-performance devices offer robust short-circuit breaking capabilities for demanding operational environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • ABB EcoSolutions: Yes
  • EcoSolutions Profile: 9AKK108471A1082
  • Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 86.29 %
  • ABB Site Meeting Group Waste To Landfill Target: No non-hazardous waste is sent to a landfill
  • End Of Life Disassembling Instructions: 9AKK108470A2575
  • Environmental Product Declaration - EPD: 9AKK108470A1695
  • Rated Ultimate Short-Circuit Breaking Capacity (I cu ): (415 V AC) 25 kA
  • Rated Service Short-Circuit Breaking Capacity (I cs ): (415 V AC) 25 kA
  • Contact Position Indication: ON / OFF / TRIP
  • Energy Limiting Class: 3
  • Electrical Endurance: 10000 cycle
  • Mechanical Endurance: 10000 cycle
  • Number of Protected Poles: 3
  • Number of Poles: 3P
  • Tightening Torque: 3.5 N·m
  • Release Type: D

More info

ABB EcoSolutions
ABB EcoSolutionsYes
EcoSolutions Profile9AKK108471A1082
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 86.29 %
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
End Of Life Disassembling Instructions9AKK108470A2575
Environmental Product Declaration - EPD9AKK108470A1695
9AKK108470A1696
Technical
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(415 V AC) 25 kA
(440 V AC) 15 kA
(375 V DC) 10 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(415 V AC) 25 kA
(440 V AC) 10 kA
(375 V DC) 10 kA
Contact Position IndicationON / OFF / TRIP
Energy Limiting Class3
Electrical Endurance10000 cycle
Mechanical Endurance10000 cycle
Number of Protected Poles3
Number of Poles3P
Tightening Torque3.5 N·m
31 in·lb
Release TypeD
Actuator MarkingI / O
Recommended Screw DriverPozidriv 2
Accessories AvailableYes
RemarksConnection from top and bottom Connecting with CU only IP40 in enclosure with cover Cage terminal with captive screw
Connecting CapacityFlexible 0 … 50 mm²
Rigid 0 … 70 mm²
Terminal TypeScrew Terminals
Electrical
Tripping CharacteristicD
Rated Operational Voltageacc. to IEC 60898-1 400 V AC
acc. to IEC 60947-2 415 V AC
Operational VoltageMaximum 230/400 V AC
Minimum 12 V AC
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Input Voltage TypeAC/DC
Rated Current (In)32 A
Rated Short-Circuit Capacity(400 V AC) 15 kA
Frequency (f)50 / 60 Hz
Rated Frequency (f)50/60 Hz
Power LossTotal 9.6 W
at Rated Operating Conditions per Pole 3.2 W
Overvoltage CategoryIV
Design
Housing MaterialInsulation group I, RAL 7035
Technical UL/CSA
Interrupting Rating acc. to UL1077(480Y / 277 V AC) 10 kA
(375 V DC) 10 kA
Material Compliance
RoHS Declaration2CCC005083D0202
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date20211214
REACH Declaration9AKK108470A9089
REACH InformationFalse - does not contain substances > 0.1 mass percentage
REACH Date20250313
Conflict Minerals Reporting Template (CMRT)9AKK108468A3363
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2BBusiness To Business
Environmental
Ambient Air TemperatureOperation -40 ... 70 °C
Storage -40 ... 70 °C
Reference Ambient Air Temperatureacc. to IEC60947-2 30 °C
acc. to EN60898-1 30 °C
Degree of ProtectionIP20
Pollution Degree3
Resistance to Vibrations1 mm 2 - 13.2 Hz
0.7g with Load 100% x Ie 13.2 - 100 Hz
Resistance to Shock acc. to IEC 60068-2-275 g
30 ms
Environmental Information2CCY413207D0203
Dimensions
Width in Number of Modular Spacings4.5
Product Net Width81 mm
Product Net Height95 mm
Product Net Depth / Length82.5 mm
Product Net Weight735 g
Built-In Depth (t2)82.5 mm
Dimension Diagram2CCC413003C0201
Engineering
EPLAN Data9AAC210421_EPLAN
Ordering
Package Level 1 Unitsbox 1 piece
Package Level 1 Gross Weight770 g
Certificates and Declarations
CB Certificate9AKK107680A0835
2CCC413029D0202
CCC CertificateCQC2014010307713173
Declaration of Conformity - CE2CCC005083D0202
ESTI Certificate2CCC413028D0101
UL Certificate9AKK107680A2286
VDE Certificate2CCC413039D0601
Installation
Instructions and Manuals2CCC413016M0008
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting PositionAny
Popular Downloads
Data Sheet, Technical Information9AKK108468A9560
9AKK108468A9561
9AKK108468A9562
External Classifications and Standards
ETIM 9EC000042 - Miniature circuit breaker (MCB)
ETIM 10EC000042 - Miniature circuit breaker (MCB)
UNSPSC39121603
eClassV11.0 : 27141901
IDEA Granular Category Code (IGCC)4899 >> Miniature circuit breaker (MCB) screw-in model
Object Classification CodeF
StandardsIEC/EN 60947-2
IEC/EN 60898-1
UL 1077

Product Datasheet